Specification:
Model IPS | 10212/24 | 20232/24/48 | 30224/48 | 40224/48 | 50248 | 60248 | ||
Rated Power | 1KW | 2KW | 3KW | 4KW | 5KW | 6KW | ||
Peak Power(20ms) | 3KVA | 6KVA | 9KVA | 12KVA | 15KVA | 18KVA | ||
Start Motor | 1HP | 2HP | 3HP | 3HP | 4HP | 4HP | ||
Battery Voltage | 12/24VDC | 12/24/48VDC | 24/48VDC | 24/48VDC | 48VDC | |||
Size(L*W*Hmm) | 500 *300*1 4 0 | 53 * 335 *1 5 0 | ||||||
Packing Size(L*W*Hmm) | 565 *3 95 *225 | 605 *4 30 *2 3 5 | ||||||
N.W.(kg) | 12 | 19 | 20 | 22 | 24 | 26 | ||
G.W.(kg)(Carton Packing) | 13 .5 | 19.5 | 21.5 | 24 | 26 | 28 | ||
Installation Method | Wall-Mounted | |||||||
Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) | ||||||
AC Input Voltage Range | 85VAC~138VAC(110VAC)95VAC-148VAC(120VAC) / 170VAC~275VAC(220VAC)/180VAC~285VAC(230VAC)/190VAC~295VAC(240VAC) | |||||||
AC Input Frequency Range | 45Hz~55Hz(50Hz)/55Hz~65Hz(60Hz)/ | |||||||
Max AC charging current | 0~30A(Depending on the model) | |||||||
AC charging method | Three-stage (constant current, constant voltage, floating charge) | |||||||
Output | Efficiency(Battery Mode) | ≥85% | ||||||
Output Voltage(Battery Mode) | 110VAC±2% / 120VAC±2%/220VAC±2%/230VAC±2%/240VAC±2% | |||||||
Output Frequency(Battery Mode) | 50/60Hz±1% | |||||||
Output Wave(Battery Mode) | Pure Sine Wave | |||||||
Efficiency(AC Mode) | >99% | |||||||
Output Voltage(AC Mode_ | 110VAC±10% / 220VAC±10% | |||||||
Output Frequency(AC Mode) | Tracking Automatically | |||||||
Output waveform distortion
(Battery Mode) |
≤3%(Linear load) | |||||||
No load loss(Battery Mode) | ≤1% rated power | |||||||
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | |||||||
No load loss
(Energy saving Mode) |
≤10W | |||||||
Battery Type
(selectable) |
||||||||
LEAD | Charge Voltage:14V;Float Voltage:13.8V(12V system; 24V system x2; 48V system x4) | |||||||
OP-LE | Charge Voltage:14.2V; Float Voltage:13.8V(12V system; 24V system x2; 48V system x4) | |||||||
LITHIUM | Charge Voltage: 12.6V(NMC battery 3S) (12V system; 24V system x2; 48V system x4) | |||||||
Customize battery | Charge and discharge parameters of different types of batteriescan be customized according to user requirements | |||||||
Protection | Battery undervoltage alarm | 11V; LITHIUM 9.5V(NMC battery 3S)(12V system; 24V system x2; 48V system x4) | ||||||
Battery undervoltage protection | 10.5V; LITHIUM 9V(NMC battery 3S)(12V system; 24V system x2; 48V system x4) | |||||||
Battery overvoltage alarm | Lead acid battery: 15V(12V system; 24V system x2; 48V system x4) | |||||||
Battery overvoltage protection | Lead acid battery: 17V(12V system; 24V system x2; 48V system x4) | |||||||
Battery overvoltage recovery voltage | Lead acid battery: 14.5V(12V system; 24V system x2; 48V system x4) | |||||||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||||||
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||||||
Temperature protection | >90°C(Shut down output) | |||||||
Alarm | A | Normal working condition, buzzer has no alarm sound | ||||||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | |||||||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | |||||||
Inside Solar controller
(Optional |
Charging Mode | PWM or MPPT | ||||||
charging current | 10A/20A/30A/40A/50A/60A/80A/100A | |||||||
PV Input Voltage Range |
PWM: 15V-44V(12V system); 30V-44V(24V system); 60V-88V(48V system)
MPPT: 15V-120V(12V system); 30V-120V(24V system); 60V-120V(48V system) |
|||||||
Max PV Input Voltage(At 25ºC) | PWM: 50V(12V/24 system), 100V(48V system ); MPPT: 150V | |||||||
PV Array Maximum Power |
12V system: 140W/280W/420W/560W/700W/840W/1120W/1400W;
24V system: 280W/560W/840W/1120W/1400W/1680W/2240W/2800W; 48V system: 560W/1120W/1680W/2240W/2800W/3360W/4480W/5600W |
|||||||
Standby loss | ≤3W | |||||||
Maximum conversion efficiency | >95% | |||||||
Working Mode | Battery First/AC First/Saving Energy Mode | |||||||
Transfer Time | ≤4ms | |||||||
Display | LCD | |||||||
Thermal method | Cooling fan in intelligent control | |||||||
Communication | RS232/RS485(Optional) | |||||||
Environment | Operating temperature | ≤55dB | ||||||
Storage temperature | -15ºC~60ºC | |||||||
Noise | -15ºC~60ºC | |||||||
Elevation | 2000m(More than derating) | |||||||
Humidity | 0%~95% ,No condensation |
1. Battery number and capacity should be configured according to the rated voltage of the solar power system or inverter;
2. We offer 3 optional working modes (transfer time≤4ms):
01 Grid priority mode:
When the grid and battery are connected to the inverter, the grid will supply power to the loads directly after the voltage is stabilized and charge batteries via an inverter. When the grid is cut off, the battery will automatically continue to supply power via an inverter.
02 Energy saving mode:
If the power of the connected AC loads is lower than 5% of the inverter's rated power, there will be no output from the inverter. Only the chip of the inverter is working. The power consumption of the inverter is only 1~6W. The LCD shows the output voltage of 0. If the power of the connected loads is over 5%, within 5S the inverter will automatically convert DC to AC to supply power for the loads. The LCD shows the output voltage.
03 Battery priority mode:
When the grid and battery are connected to the inverter, the battery will supply power to the loads first. When battery capacity is not enough, the grid will continue to supply power automatically.