Model | Pressure boost ratio |
Min. gas
Inlet pressure P A (bar) |
Max.gas
Inlet pressure P A (bar) |
Max. gas
outlet pressure P B (bar) |
Driven air pressure P L |
Formula to
calculate gas outlet pressure P B |
Connection:
Gas Inlet / Gas outlet (NPT thread) |
Max. flow at driven air pressure of 6bar (L/min) |
DGA02 | 2 : 1 | 1.0 | 16 | 16 | 2bar-8 bar | 2X P L | 1/2 / 1/2 | 960 (at P A of 6 bar ) |
DGA05 | 5 : 1 | 0 | 40 | 40 | 2bar-8 bar | 5XP L | 1/2 / 1/2 | 680(at P A of 6 bar ) |
DGA06 | 6 : 1 | 2.0 | 48 | 48 | 2bar-8 bar | 6XP L | 1/2 / 1/2 | 360(at P A of 10 bar ) |
DGA10 | 10 : 1 | 3.5 | 80 | 80 | 2bar-8 bar | 10XP L | 3/8/ 3/8 | 210(at P A of 10 bar ) |
DGA25 | 25 : 1 | 7.0 | 200 | 200 | 2bar-8 bar | 25XP L | 1/4/ 1/4 | 120(at P A of 20 bar ) |
DGA40 | 40 : 1 | 10 | 320 | 320 | 2bar-8 bar | 40XP L | 1/4/ 1/4 | 200(at P A of 40 bar ) |
DGA60 | 60 : 1 | 20 | 480 | 480 | 2bar-8 bar | 60XP L | 1/4/ 1/4 | 180(at P A of 40 bar ) |
DGA100 | 100 : 1 | 25 | 800 | 800 | 2bar-8 bar | 100XP L | 1/4/ M14X1.5 | 136(at P A of 40 bar ) |
Model | Pressure boost ratio |
Min. gas
Inlet pressure P A (bar) |
Max.gas
Inlet pressure P A (bar) |
Max. gas
outlet pressure P B (bar) |
Driven air pressure P L |
Formula to
calculate gas outlet pressure P B |
Connection:
Gas Inlet / Gas outlet (NPT thread) |
Max. flow at driven air pressure of 6bar (L/min) |
DGD10 | 10:1 | 3.5 | 80 | 80 | 2bar-8 bar | 10XPL+ PA | 3/8/3/8 | 410(at PA of 6 bar ) |
DGD25 | 25:1 | 10 | 200 | 200 | 2bar-8 bar | 25XPL+ PA | 1/4/1/4 | 396(at PA of 20 bar ) |
DGD40 | 40:1 | 15 | 320 | 320 | 2bar-8 bar | 40XPL+ PA | 1/4/1/4 | 320(at PA of 40 bar ) |
DGD60 | 60:1 | 25 | 480 | 480 | 2bar-8 bar | 60XPL+ PA | 1/4/1/4 | 215(at PA of 40 bar ) |
DGD100 | 100:1 | 35 | 800 | 800 | 2bar-8 bar | 100XPL+ PA | 1/4/M14*1.5 | 300(at PA of 60 bar ) |
DGD130 | 130:1 | 50 | 1040 | 1040 | 2bar-8 bar | 130XPL+ PA | 1/4/M14*1.5 | 180(at PA of 60 bar ) |
Model | Pressure boost ratio |
Min. gas
Inlet pressure P A (bar) |
Max.gas
Inlet pressure P A (bar) |
Max. gas
outlet pressure P B (bar) |
Driven air pressure P L |
Formula to
calculate gas outlet pressure P B |
Connection:
Gas Inlet / Gas outlet (NPT thread) |
Max. flow at driven air pressure of 6bar (L/min) |
2DGD10 | 10:1 | 3 | 80 | 80 | 2bar-8 bar | 2bar-8 bar | 1/2 / 1/2 | 980(at PA of 6 bar ) |
2DGD25 | 25:1 | 6 | 200 | 200 | 2bar-8 bar | 2bar-8 bar | 3/8 / 3/8 | 560(at PA of 10 bar ) |
2DGD40 | 40:1 | 25 | 320 | 320 | 2bar-8 bar | 2bar-8 bar | 3/8 / 3/8 | 480(at PA of 40 bar ) |
2DGD60 | 60:1 | 30 | 480 | 480 | 2bar-8 bar | 2bar-8 bar | 3/8 / 3/8 | 320(at PA of 40 bar ) |
Model | Pressure boost ratio |
Min. gas
Inlet pressure P A (bar) |
Max.gas
Inlet pressure P A (bar) |
Max. gas
outlet pressure P B (bar) |
Driven air pressure P L |
Formula to
calculate gas outlet pressure P B |
Connection:
Gas Inlet / Gas outlet (NPT thread) |
Max. flow at driven air pressure of 6bar (L/min) |
DGT25 | 25:1 | 0.1 | 10 | 200 | 2-8 bar | 25XP L +3.5XP A | 3/8/ 1/4 | 136(at P A of 8 bar ) |
DGT40 | 40:1 | 0.1 | 10 | 320 | 2-8 bar | 40XP L + 6XP A | 3/8/ 1/4 | 124(at P A of 8 bar ) |
DGT10/60 | 10:1/60:1 | 0.1 | 10 | 480 | 2-8 bar | 60XP L +6X P A | 3/8/ 1/4 | 84(at P A of 8 bar ) |
DGT25/60 | 25:1/60:1 | 10 | 25 | 480 | 2-8 bar | 60XP L +2.5XP A | 3/8/ 1/4 | 80(at P A of 15 bar ) |
DGT100 | 100:1 | 0.1 | 10 | 800 | 2-8 bar | 100XP L +10XP A | 3/8/ M14*1.5 | 63(at P A of 8 bar ) |