Pre-Fabricated Substation for Parks

Model NO.
YBM-10
Brand
Dechun
Transport Package
Wooden Cases
Trademark
DECHUN
Origin
Changzhou, Jiangsu, China
Reference Price
$ 450.00 - 2,700.00

Product Description


Technical Specification:
Item Unit Parameter
Rated voltage KV 12/0.4 24/0.4
Rated short-time power frequency withstand voltage(phase/fracture) KV/1 min 42/48 42/48
Rated lighting impulse withstand voltage(phase/ground) KW 75/85 75/85
Rated frequency Hz 50 50
Rated total loss KW 7.01 7.01
Rated maximum capacity A 630 630
Ground circuit short time withstand current and duration KA/S 20/0.5s 20/0.5s
Rated peak withstand current KA 50 50
Enclosure rating   IP30 IP33D
Rated housing rating   10 10

Product description:
YB typed pre-fabricated substation is for HV/LV equipment,transformer combination of a compactly equipment device.Widely used in urban high-rise buildings,urban and rural construction,residential areas,factories,parks,airports,railway,oil field,shopping malls and
temporary construction and other outdoor venues.For receiving anddistribution of electric energy in power distribution system.

Features:
1.Substation shell adopts the surface treatment of steel manufacturing,has enough mechanical strength and rigidity.
2.The shell material is made of cold rolled steel plate,stainless steel plate,aluminum alloy plate,after choi plate,etc
3.Each chamber is use the steel plate into separate little room,the Layout is designed to ' ' or ' '  shape based on electricity demand.
4.To convenience to monitoring and maintenance,transformer room, high and low voltage room is equipped with lighting device.
5.The top plate with double-layer structure,to prevent thermal radiation increase indoor temperature.
6.Transformer is with natural ventilation,when the transformer  room temperature more than setted temperature,the top of the   axial flow fan antomatically start to control the temperature of  the transformer room.
7The connection parts equipped with sealing device,has the good moistureproof function.
Perfect protection performance,convenient operation,ensure the  Safety of maintenance;

Applicable conditions:
Altitude :≤ 2000m
Ambient temperature : -35 ºC ~+40 ºC
Relative humidity :
Daily average 95 %
Monthly average 90 %
Seismic capacity : 8 degree s  
Current AC
Altitude ≤2000m
Ambienttemperature -35ºC-+40ºC
Seismic Capacity 8 degree

Pre-Fabricated Substation for Parks
Pre-Fabricated Substation for Parks
Pre-Fabricated Substation for Parks
Pre-Fabricated Substation for Parks
Pre-Fabricated Substation for Parks




 

 

PNEUTEC.IT, 2023