Powered by PERKINS | 400V, 1500RPM, 50Hz | ||||||||||
Genspark | Standby | Prime | Engine | Alternator | Dimension mm | Dimension mm | Fuel Cons | Displacement | Cylinder | Gov |
Model | kVA | kVA | Model | Stamford | Open Type | Soundproof Type | 75%(L/H) | L | ||
GS-P16 | 16.5 | 15 | 403A-15G2 | S0L1-P1 | 1300*690*1320 | 1710*880*1350 | 3.3 | 1.496 | 3 | M |
GS-P22 | 22 | 20 | 404D-22G | S0L2-G1 | 1470*690*1320 | 1910*880*1450 | 4.1 | 2.216 | 4 | M |
GS-P34 | 33 | 30 | 1103A-33G | S0L2-P1 | 1760*760*1380 | 2290*1060*1680 | 5.3 | 3.3 | 3 | M |
GS-P65 | 65 | 60 | 1103A-33TG2 | S1L2-Y1 | 1760*760*1380 | 2290*1060*1680 | 10.8 | 3.3 | 3 | M |
GS-P70 | 71.5 | 65 | 1104A-44TG1 | UCI 224F1 | 1760*760*1380 | 2440*1060*1680 | 10.9 | 4.4 | 4 | M |
GS-P88 | 88 | 80 | 1104A-44TG2 | UCI 224G1 | 2000*900*1550 | 2810*1140*1830 | 14 | 4.4 | 4 | E |
GS-P110 | 110 | 100 | 1104C-44TAG2 | UCI 274C1 | 2150*900*1550 | 2810*1140*1830 | 16.8 | 4.4 | 4 | E |
GS-P200 | 200 | 182 | 1106A-70TAG3 | UCI 274G1 | 2550*930*1670 | 3590*1250*2050 | 30.2 | 7.01 | 6 | M |
GS-P220 | 220 | 200 | 1106A-70TAG4 | UCI 274H1 | 2550*930*1670 | 3590*1250*2050 | 33.7 | 7.01 | 6 | M |
GS-P275 | 275 | 250 | 1506A-E88TAG3 | UCDI 274K1 | 2580*930*1670 | 3590*1250*2050 | 39.4 | 8.8 | 6 | E |
GS-P400 | 400 | 350 | 2206C-E13TAG2 | S4L1D-E41 | 3100*1120*1788 | 4230*1460*2150 | 64 | 12.5 | 6 | E |
GS-P450 | 450 | 400 | 2206C-E13TAG3 | S4L1D-F41 | 3100*1120*1788 | 4230*1460*2150 | 72 | 12.5 | 6 | E |
GS-P500 | 500 | 450 | 2506C-E15TAG1 | S4L1D-G41 | 3400*1270*1974 | 4630*1660*2250 | 73 | 15 | 6 | E |
GS-P550 | 550 | 500 | 2506C-E15TAG2 | HCI 544C1 | 3400*1270*1974 | 4630*1660*2250 | 82 | 15 | 6 | E |
GS-P700 | 700 | 635 | 2806A-E18TAG2 | HCI 544FS1 | 3600*1400*2100 | 5030*1660*2550 | 95 | 18.13 | 6 | E |
GS-P720 | 715 | 650 | 2806A-E18TAG2 | HCI 544F1 | 3600*1400*2100 | 5030*1660*2550 | 97 | 18.13 | 6 | E |
GS-P825 | 825 | 750 | UK 4006-23TAG2A | LV1 634B1 | 3965*1710*2200 | 5800*1800*2550 | 119 | 22.921 | 6 | E |
GS-P880 | 880 | 800 | UK 4006-23TAG3A | S6L1D-C4 | 3965*1710*2200 | 5800*1800*2550 | 131 | 22.921 | 6 | E |
GS-P880 | 880 | 800 | India 4006-23TAG3A | S6L1D-C4 | 3965*1710*2200 | 5800*1800*2550 | 131 | 22.921 | 6 | E |
GS-P1100 | 1100 | 1000 | UK 4008TAG2A | S6L1D-E4 | 4650*2046*2300 | ISO 20'ft GP | 158 | 30.561 | 8 | E |
GS-P1100 | 1100 | 1000 | India 4008TAG2A | S6L1D-E5 | 4650*2046*2300 | ISO 20'ft GP | 158 | 30.561 | 8 | E |
GS-P1250 | 1250 | 1125 | India 4008-30TAG3 | S6L1D-F4 | 4650*2046*2300 | ISO 20'ft GP | 176 | 30.561 | 8 | E |
GS-P1375 | 1375 | 1250 | UK 4012-46TWG2A | S6L1D-G4 | 4700*1780*2400 | ISO 20'ft GP | 209 | 45.842 | 12V | E |
GS-P1650 | 1650 | 1500 | UK 4012-46TAG2A | S7L1D-C4 | 5000*2200*2850 | ISO 40'ft HQ | 236 | 45.842 | 12V | E |
GS-P1650 | 1650 | 1500 | India 4012-46TAG2A | S7L1D-C4 | 5000*2200*2850 | ISO 40'ft HQ | 236 | 45.842 | 12V | E |
GS-P1800 | 1812.5 | 1650 | India 4012-46TAG3A | PI 734D1 | 5100*2200*2850 | ISO 40'ft HQ | 264 | 45.842 | 12V | E |
GS-P1875 | 1875 | 1705 | UK 4012-46TAG3A | S7L1D-E4 | 5100*2200*2850 | ISO 40'ft HQ | 272 | 45.842 | 12V | E |
GS-P2000 | 2000 | 1850 | India 4016TAG1A | S7L1D-F4 | 5400*2650*2650 | ISO 40'ft HQ | 281 | 61.123 | 16V | E |
GS-P2000 | 2000 | 1850 | 4016-61TRG1 | S7L1D-F4 | 5400*2650*2650 | ISO 40'ft HQ | 277 | 61.123 | 16V | E |
GS-P2250 | 2250 | 2050 | 4016-61TRG2 | PI 734F or S7L1D-G4 | 5400*2650*2650 | ISO 40'ft HQ | 309 | 61.123 | 16V | E |
GS-P2250 | 2250 | 2050 | India 4016TAG2A | PI 734F or S7L1D-G4 | 5400*2650*2650 | ISO 40'ft HQ | 318 | 61.123 | 16V | E |
GS-P2500 | 2500 | 2272.5 | UK 4016-61TRG3 | S7L1D-J4 or PI 734H1 | 6000*2700*3400 | ISO 40'ft HQ | 354 | 61.123 | 16V | E |
GS-P2500 | 2500 | 2272.5 | India 4016-61TRG3 | S7L1D-J4 or PI 734H1 | 6000*2700*3400 | ISO 40'ft HQ | 354 | 61.123 | 16V | E |
Helpful tips on Generator Set Fault | |||
When fault occurs during generator set running,could do primary judgement according to following tips. | |||
Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. |
Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. |
Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. |
Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. |
Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |