XH-WCF-17/18 Usage
WCF-17/18 high-temperature Boiler Forced Draft Fan is used to burn a variety of coal and with smoke and dust removal device 1t / h ~ 20t / h industrial boiler design, where the intake conditions are comparable, similar performance can also be used, But the maximum temperature shall not exceed 600 ºC; in the high-temperature fan, you must install the efficiency of not less than 85% of the dust removal device to reduce the smoke into the fan dust, improve fan life.
Parameters
Type 4C
Speed
r/min
|
No.
|
Volume
m3/h
|
Total Pressure
Pa
|
Internal Efficiency
%
|
Inner Power
kw
|
Required Power
kw
|
Motor
|
Power
kw
|
3550
|
1
2
3
4
5
6
7
|
2932
3374
3807
4254
5686
5143
5564
|
1555
1578
1521
1448
1340
1208
1051
|
70
74.1
77.2
78.7
77.7
74.4
70
|
2.57
2.83
2.95
3.08
3.18
3.30
3.30
|
3.52
3.87
4.04
4.22
4.36
4.51
4.52
|
5.5
|
3150
|
1
2
3
4
5
6
7
|
2602
2993
3378
3775
41158
4563
4937
|
1222
1240
1196
1138
1054
950
826
|
70
74.1
77.2
78.7
77.7
74.4
70
|
1.80
1.97
2.06
2.15
2.22
2.30
2.31
|
2.46
2.70
2.82
2.95
3.04
3.15
3.16
|
4
|
2800
|
1
2
3
4
5
6
7
|
2313
2661
3003
3355
3696
4056
4288
|
964
979
944
898
832
750
652
|
70
74.1
77.2
78.7
77.7
74.4
70
|
1.26
1.39
1.45
1.51
1.56
1.62
1.62
|
1.73
1.90
1.98
2.07
2.14
2.21
2.22
|
3
|
2500
|
1
2
3
4
5
6
7
|
2065
2376
2681
2996
3300
3622
3918
|
768
779
751
715
662
597
519
|
70
74.1
77.2
78.7
77.7
74.4
70
|
0.90
0.99
1.03
1.08
1.11
1.15
1.53
|
1.23
1.35
1.41
1.47
1.52
1.57
1.58
|
2.2
|
Type 5C
Speed
r/min
|
No.
|
Volume
m3/h
|
Total Pressure
Pa
|
Internal Efficiency
%
|
Inner Power
kw
|
Required Power
kw
|
Motor
|
Power
kw
|
3150
|
1
2
3
4
5
6
7
|
5304
6062
6820
7578
8336
9093
9851
|
1973
1955
1916
1814
1684
1523
1339
|
72
75.9
78.7
80
79.1
76
72
|
5.71
6.13
6.52
6.76
6.98
7.17
7.22
|
7.81
8.39
8.92
9.25
9.55
9.81
9.88
|
11
|
2800
|
1
2
3
4
5
6
7
|
4715
5389
6062
6736
7409
8083
8757
|
1556
1542
1511
1431
1329
1201
1056
|
72
75.9
78.7
80
79.1
76
72
|
4.01
4.31
4.58
4.75
4.90
5.03
5.07
|
5.49
5.90
6.27
6.50
6.71
6.89
6.94
|
7.5
|
2500
|
1
2
3
4
5
6
7
|
4210
4811
5413
6014
6616
7217
7818
|
1238
1227
1203
1139
1058
956
841
|
72
75.9
78.7
80
79.1
76
72
|
2.85
3.07
3.26
3.38
3.49
3.58
3.61
|
3.90
4.20
4.46
4.62
4.77
4.90
4.94
|
5.5
|
2240
|
1
2
3
4
5
6
7
|
3772
4311
4850
5389
5928
6466
7005
|
993
984
964
914
848
767
675
|
72
75.9
78.7
80
79.1
76
72
|
2.05
2.21
2.34
2.43
2.51
2.58
2.60
|
2.81
3.02
3.21
3.33
3.43
3.53
3.55
|
4
|
Ordering instructions
When ordering, please specify the fan number, speed, air volume, wind pressure, outlet angle and direction of rotation, as well as motor model, power, speed and so on.
The most important factors are volume and pressure.
To make the proper fan selection, you must consider the following system conditions the fan will be subjected to:
1. What is the required airflow?
This is rated in cubic feet of air per minute (CFM) or, in metric equivalent, it is rated in cubic meters of air per hour (M³/Hr).
2. What is the static pressure through the complete system?
This is rated in static pressure water gauge (SP) or, in metric equivalent, it is rated in Pascal's (Pa).
3. What is the ambient air temperature outside the fan?
4. What will be the airflow conditions through the fan?
A. Clean or dirty (contaminated) air?
B. Dry or wet (moisture laden) air?
C. Temperature of air?
5. What is the altitude the fan will be operating in?
6. Will the air stream, inside the fan, contain anything that could be explosive or flammable?
7. Will the general location the fan will be operating in contain any type of explosive or flammable material or liquid?
Customized
When the exiting machine number, rotation, the wind angle and transmission mode can not meet the needs of users, we can design according to the fan similar theory and the user's specific parameters requirements.
Technical Support Service
When using our products, If any problems on installation,operation,maintainance..and so on, please contact our sale manager directly or leave a message on our website, we will call you in the first time.
Detailed Performance Catalog
Contact our sales manager to get a list of available fan sizes and to view detailed performance curves for each fan KuangFeng builds.
Company & Brand
KuangFeng fans are built by Zibo Xinhua Fan Co., Ltd. In Shandong, China. XFC has served the mining and industrial field for 24 years.
The factory was founded in 1993 and covers an area of 12, 000 square meters. Products are widely used in boilers, workshops, mines, textiles, oil, chemical, kiln, metallurgy, building materials and other industries, Our main products are mine fan, axial fan, open cotton fan, material transmission fan.
KuangFeng Fans has a wide selection of fans available, from 0.25 horsepower to 1120 horsepower and from 0.98 inch diameter to 11 inch diameter(impeller diameter). Contact us to get a list of available fan sizes and to view detailed performance curves for each fan KuangFeng builds.
KuangFeng Fan manufacture 200 series and more than 1,200 kinds of industrial fans. All include heavy-duty designs for industrial applications. We manufacture axial fans, centrifugal fans, mine fans and miniature fans. All fans below 600mm(impeller size) are direct driven. All fans above 600mm are available in both direct driven or belt driven models. All models are available with cast aluminum, steel or stainless steel propellers. All models can also be manufactured in all aluminum or all stainless steel construction.
We understand the harsh environments in which fans are used. KuangFeng fans will meet and exceed the demands of your mine or tunnel project, other industrial factory.
Delivery & Package
Packing Details
Complete sets of supply
Fan 1, adjustable door 1, matched motor 1, the motor rails 1 (2 sets), the foundation bolts 1, motor pulley 1, triangle tape 1.