| Type | 2KW Off-grid system | |||
| Inquirement | 5KW load power demand;Standard configuration;System voltage DC96V | |||
| System configuration and quotation | ||||
| Item | Name of Equipment | Specification | Qty | |
| 1 | Solar Panels | Poly 325W | 4pcs | |
| 2 | bracket | C type steel | 1set | |
| 3 | DC-AC Power Inverter | JN-H-2000 | 1set | |
| 4 | Solar Controller JN-MPPT-CL | JN-MPPT-BL | 1pcs | |
| 5 | Gel battery | 12V-200AH | 4pcs | |
| 6 | cable | PV-F1*4mm² | 60m | |
| BVR-16mm² | 30m | |||
| BVR-16mm² | 10m | |||
| BVR-6mm² | 10m | |||
| 7 | battery bracket | angle steel | 1set | |
| 8 | AC box | 5KW/220VAC | 1 | |
| 9 | Assembly connection male/female plug | MC4 | 3 | |
|
Power Level
|
2000W
|
||
|
Peak Power
|
4KW(<1S)
|
||
|
Input Voltage
|
24v | ||
|
Output
Voltage
|
100VAC±5%/110VAC±5%/120VAC±5%
or 200VAC±5%/220VAC±5%/240AC±5%(Can custom)
|
||
|
Output
Frequency
|
50HZ±0.5HZ or 60HZ±0.5HZ
|
||
|
Output
Waveform
|
Pure Sine Wave
|
||
|
Wave form
distortion
|
THD
<
3%(linear load)
|
||
|
Output Peak
Efficiency
|
Maximum 94%
|
||
|
Starting Mode
|
Front and back the bipolar soft stat
|
||
|
Switching
Time
|
<=10mS
|
||
|
Switching
Way
|
DC/AC can be automatically set priorities
|
||
|
Cooling
|
Intelligent air cooled (fan start over 45 degrees)
|
||
|
Protect
Function
|
Under voltage /Overvoltage
|
||
|
Over-Load
|
|||
| Model |
JN-MPPT-BL
|
JN-MPPT-CL | |||||||||
|
Current rating (A)
|
30 | 40 | 50 | 60 | 70 | 50 | 60 | 80 | 100 | 120 | |
|
PV maximum
input power
(24V) (W)
|
800 | 1000 | 1200 | 1500 | 1700 | 1200 | 1500 | 2000 | 2400 | 2900 | |
|
PV maximum
input power
(48V) (W)
|
1600 | 2000 | 2400 | 3000 | 3400 | 2400 | 3000 | 4000 | 4800 | 5500 | |
|
System
identification
voltage range v
|
24V battery system:DC18V-DC32V
48V battery system:DC42V-DC60V |
||||||||||
|
PV panel open
circuit input
voltage range v
|
40V
~
145V(24V battery system)
80V ~ 145V(48V battery system) |
||||||||||
|
MPPT efficiency
|
>
99.5%
|
||||||||||
|
Conversion
efficiency
|
>
98%
|
||||||||||
|
Operating mode
|
The default is the household mode 24H
|
||||||||||
| Battery parameter reference table: | |||||||||||
|
Overvoltage
(overcharge
(
v
)
|
26
~
34V@24V system
52
~
68V@48V system
|
||||||||||
|
Over voltage
return (v)
|
|||||||||||
|
Charge limit
voltage
(
v
)
|
18~ 30V@24V system
36~60
V@48V system
|
||||||||||
|
Boost charge
(
v
)
|
|||||||||||
|
Boost charge
return
(
v
)
|
|||||||||||
|
Float voltage (v)
|
|||||||||||
|
Over discharge (v)
|
14~26
V@24V system
28~52
V@48V system
|
||||||||||
|
Over discharge
return
(
v
)
|
18~
30V@24V system
36~60
V@48V system
|
||||||||||
|
Ternary lithium battery & Lithium LIFEPO4
|
|||||||||||