| Capacity | ||
| Control mode | PWM ZVZCS soft switching inverter technology | |
| Control technology | 16 bit MCU+CPLD | |
| Input | Input voltage range | Single phase 22 0V±15% /Three phase 380V ±15% |
| Frequency | 47-63HZ | |
| Output | external characteristic | CV & CC |
| Rating output voltage | Rating V | |
| Output voltage range | 0~ Rating V adjustable | |
| Rating output current | Rating A | |
| Output current range | 0~100% Rating output current | |
| Source voltage stability | < 0. 5 % @FS | |
| Load stability | < 1% @FS | |
| ripple voltage(r.m.s) | < 0.5% @FS | |
| Transient response time | <10ms | |
| Efficiency | >90% @ 100% load | |
| Display | digital voltmeter | 4 bit LED display (0.1V) specification :±0.5%rdg+2digit |
| digital ammeter | 4 bit LED display (1A) specification :±0.5%rdg+2digit | |
| Working conditions | storage temperature | -20ºC~+50ºC |
| working temperature | -10ºC~+40ºC | |
| relative humidity | ≤95%(no condensation) | |
| levels of protection | IP20 | |
| atmospheric pressure | 80~106KPc(altitude below 2000m) | |
| noise | < 65 dB at 1 meter | |
| Protection | The input phase lack protection | Three phase input short phase protection and alarm |
| Input o vervoltage p rotection | Stop working and alarm when the voltage of input is output of the range | |
| Input under voltage protection | Stop working and alarm when the voltage of input is output of the range | |
| Output over voltage protection | Automatic protection and alarm when the output voltage is higher than the set value | |
| Output overcurrent protection |
The output current exceeds the set value.
a utomatic current limiting after delay start. |
|
| short-circuit protection |
The output end can be short circuited for a long time, and there is a sound and light alarm
when
short circuit.
When the short circuit is removed, the power is automatically restored to normal work |
|
| overheat protection | >85 ºC protect and alarm | |
| Insulation requirements | insulation strength | I nput to the casing for AC 2500V/1minute, leakage current 10mA |
| Input to output AC 3000V/1minute, leakage current 10mA | ||
| Output to the casing AC 3000V/1minute, leakage current 10mA | ||
| insulation resistance | Input to the casing : DC1000V, larger than 20M Omega | |
| Input to output: DC1000V, greater than 20M Omega | ||
| Output to the casing : DC1000V, greater than 20M Omega | ||
| Cooling | Forced fan cooling | |
| chassis | ||
|
Output configuration
|
Two output modes of output terminal with fast terminal and junction board | |