Model | IPS-ATDY25020 |
AC Input | Single phases 220V AC |
Input Voltage Range | 220VAC±1 5 % |
Input frequency | 50Hz/60Hz |
Output voltage | 0~250VDC |
Output current | 0.1~20A |
Output Power | 5000W |
Voltage Stabilization | ≤0.3%+10mV |
Load Stabilization | ≤0.5%+30mV |
Ripples and Noises | ≤0.5%+10mVrms |
Voltage Display Accuracy | 4-digit Accuracy: ±1%+1 word (10%-100% rating) |
Display Format | 0.000V-9.999V; 0.00V-99.99V; 0.0V-999.9V |
Current Display Accuracy | 4-digit Accuracy: ±1%+1 word (10%-100% rating) |
Remote Adjustment | (Analog control: Voltage adjustable ):0-5VDC;(Current adjustable):0-5VDC |
Remote Display | (Analog control: Voltage adjustable ): 0-5VDC;(Current adjustable):0-5VDC |
Output Over Voltage Protection | Built-in O.V.P. protection, protection limited value is rated +5% |
Output Over Load Protection | Overload, current limit, constant current output |
Over Temperature Protection | Built-in O.T.P. protection , P rotection value 85ºC±5% heat sink temperature |
Voltage Setting | 10-turn precision potentiometer |
Current Setting | 10-turn precision potentiometer |
Output Polarity | Output Positive(+) negative(- ) Can be grounded at will |
Heat Dissipation Way | Forced fan cooling |
Work Conditions | Indoor use design, T emperature:0ºC~40ºC; Humidity: 10%~85%RH |
Storage Conditions | Temperature:-20ºC~70ºC;Humidity: 10%~90%RH |
Machine /Package Dimension | L483 *W 485 H 135(MM) /L69*W55*H26(CM) |
Net w eight / Gross weight |
22KG/35KG
|
MODEL | OUTPUT VOLTAGE | OUTPUT CURRENT | OUTPUT POWER |
IPS-ATDY25200 | 25 VDC | 200A | 5000W |
IPS-ATDY40125 | 40 VDC | 125A | 5000W |
IPS-ATDY50100 | 50 VDC | 100A | 5000W |
IPS-ATDY8062.5 | 80 VDC | 62.5A | 5000W |
IPS-ATDY10050 | 100 VDC | 50A | 5000W |
IPS-ATDY12540 | 125 VDC | 40A | 5000W |
IPS-ATDY20025 | 200 VDC | 25A | 5000W |
IPS-ATDY25020 | 250 VDC | 20A | 5000W |
IPS-ATDY40012.5 | 400 VDC | 12.5A | 5000W |
IPS-ATDY50010 | 500 VDC | 10A | 5000W |
IPS-ATDY6258 | 625 VDC | 8A | 5000W |
IPS-ATDY8006.25 | 800 VDC | 6.25A | 5000W |
IPS-ATDY10005 | 1000 VDC | 5A | 5000W |
IPS-ATDY12504 | 1250 VDC | 4A | 5000W |
IPS-ATDY15003.3 | 1500 VDC | 3.3A | 5000W |
IPS-ATDY20002.5 | 2000 VDC | 2.5A | 5000W |
IPS-ATDY25002 | 2500 VDC | 2A | 5000W |
IPS-ATDY30001.67 | 3000 VDC | 1.67A | 5000W |
IPS-ATDY50001 | 5000 VDC | 1A | 5000W |
Power supply adjustable
is widely used in industrial control, electronic power, electroplating, communication, scientific research, instrument, medical, ship, railway and other high-tech fields.
The details are as follows:
1. Motor: electric motor, electric vehicle controller, dc motor test, etc
2. Electric tools: LED test and aging, energy-saving bulb testing and aging, lamp testing, tungsten gasification, etc
3. Automobile: automobile electronics, high power dc motor, automobile motor controller, car lighting, cigarette lighter, automobile audio and video, etc
5. Electronic devices: capacitors, resistors, relays, transistors, sensors, etc
6. Display: display screen, liquid screen, touch screen, on-board DVD, mobile phone display, etc
7. Electrochemical class: electrolysis, electroplating, anodic oxidation, nonferrous metal research, etc
Product Overviews
Operation-Adjustable dc power supply
1. Before connecting with loads, please preset the needed output voltage, or check the output voltage is suitable or not, or adjust the voltage potentiometer and current potentiometer to a minimum.
2. Please connect with loads when POWER OFF. Then turn Power ON. Turn the Voltage potentiometer, a current potentiometer to a minimum at first. After the power supply machine works steadily, then adjust the needed output voltage which can avoid the overshoot voltage to damage the load's equipment.
3. In-running status, you can adjust the voltage potentiometer, a current potentiometer to change the output voltage and output current as you need.
4. Internal fan is temperature-control, only when high temperature, the fan will work when low temperature the fan will stop.
5. Internal radiating wind hole: left-in and right-out, please make sure there is no barrier in the left and right wind hole.