Item | Unit | Min | Typical | Max | Testing Conditions |
Input voltage ran ge | Vac | 160 | 220 | 290 | |
Input voltage frequency range | Hz | 47 | 50 | 63 |
Output voltage | Output voltage range | Output current range | Regulator precessi o n | Load regulation | Voltage regulation | Ripple |
+28 V | 27.85 - 28.3V | 0A ~ 4A | ≤± 2 % | ≤± 2 % | ≤± 1 % | ≤ 200 m V |
+ 7 V | 6 .9 - 7 .2V | 0 A ~ 4A | ≤± 2 % | ≤± 2 % | ≤± 1 % | ≤ 200 m V |
MODEM(+9 V ) | 8.9 - 9.2V | 0A ~ 1A | ≤± 2 % | ≤± 2 % | ≤± 1 % | ≤ 20 0 m V |
C harge 8V | 7.9 - 8.3V | 0 A ~ 0. 1 A |
Item | Unit | Min | Typical | Max | Testing Conditions |
Output Power | W | - | 160 | ||
Output Efficiency | % | 75 | - | Rated input/output | |
Temp erature coefficient | / ºC | ± 0.02 % | |||
Lasting time @turn-off | mS | 10 | |||
Output put-off @turn-on | S | 1 | 5 | ||
Over-rush @dynamic response | ± 3% | ||||
Recovery time for Over-rush @dynamic response | uS | 500 |
W
ith load
25%-50%-25%
,
50%-75%-50% |
||
Over-rush @on-off | ± 3% |
Item | Unit | Min | Typical | Max | Recovery characterist ics |
Input over-voltage protection | V | 295 | 305 | 310 | Auto recovery |
Recovery point for Input over-voltage protection | V | 285 | 298 | 305 | |
Input wanting-voltage protection | V | 140 | 148 | 155 | |
Recovery point for Input wanting-voltage protection | V | 150 | 156 | 165 | |
Charging @ wanting-voltage | V | 5.0 | 5.2 | 5.5 | |
+28V out put over-voltage protection | V | 29 | 31.1 | 32 | Auto recovery |
+7V out put over-voltage protection | V | 8.5 | 9.5 | 10.5 | |
MODEM out put over-voltage protection | V | 10 | 11 | 12 | |
+28V output limited current protection | A | 4.5 | 6.7 | 8 | Auto r ecovery |
+7V output limited current protection | A | 4.5 | 6 | 7 | |
MODEM output limited current protection | A | 1.5 | 3 | 4 | |
Over-heating protection | ºC | 95 | 100 | 105 | Auto recovery |
Short-circuit protection | Auto recovery | ||||
Description for charging | Output will not stable at charging voltage with no load. To begin charging after connect with battery, and shut off the charging voltage after full. Discharge to 5.0-5.5V, battery charge again automatically. |
Item | Level | Standards ( or testing conditions ) |
Insulation volta
ge
(output to ground) |
500Vdc | 500Vdc /1Min / Leakage Current ≤ 10mA |
Insulation voltage
( input to ground) |
1500Vac | 1500Vac /1Min / Leakage Current ≤ 10mA |
Insulation voltage
( input to output) |
15 00Vac | 15 00Vac /1Min / Leakage Current ≤ 10mA |
Insulation resistance | 10 0 M Ω | Under normal atmospheric pressure, and when the relative humidity is 90%, and the testing voltage is DC 500v, for the power supply, the insulation resistance of input to output, input to ground, and output to ground is no less than 100 M Ω . |
Item | Index requirements | Standards |
CE | CLASS A | EN55022 |
RE | CLASS A | EN55022 |
ESD | LEVEL 3 | EN61000-4-2( CLASS B) |
ESD |
There is no influence on the operation of power supply when charge on the case after power supply is encased
Tangent discharge :± 6 KV Air discharge :± 8 KV |
EN61000-4-2( CLASS B) |
EFT/B | LEVEL 3 : 2KV | IEC61000-4-4 |
SURGE |
LEVEL 3
:
line
-
line
2KV
line - GND 4KV |
EN61000-4-5 |
DIP |
Drop to
70
%,
40
%,
0
%
L asting time 10 ms 1 00 m s 100 0 ms |
IEC61000-4-11 |
Item | Index requiremen ts | Performance |
Noise | The noise of power supply should be less than 55dB(A), the condition is in the range of input voltage and output voltage and current, the distance is 1 meter from front , back, right and left, and 1.5 meter from upper and underside. | Pass |
MTBF | 100,000H | |
Vibration |
>Frequency
: 5 to
10
Hz
>Amplitude : 3.5mm,9~200Hz >Direction : 3 directions >Sweep time : 5 0minutes ( 50 minute per one way ) > acceleration :10m/s2, > there is no influence on power supply. |
Pass |
Shock |
Half-
sine wave
,
acceleration
: 20G
,
Amplitude
11
ms
,
Direction
: 3 direc
tions
(X
,
Y
,
Z)
3 times per one direction |
Pass |
Dustproof | Has some function of dustproof | Pass |
O dor | No peculiar smell and deleterious gas | Pass |