C--L--X Type Mv-105 or Mc-Hl - 750 Mcm AWG - Yellow Jacket 3/C 500mcm Power Cable

Model NO.
MC HL cable
Wire Core Material
Bare Copper Wire
Model
Mc Hl Cables
Brand
Rneda
Armor Material
Steel or Aluminum
Products Name
Mc-Hl Cable
Performance
CT Use
Flame Retardant
Yes
Type
Power Cable
Armor
Aluminum Alloy
Standard
UL 1072
Rated Voltage
5-25kv
Core
1 3
Conductor
Copper
Transport Package
Steel-Wooden Drum, Steel Drum
Specification
UL1072
Trademark
RNEDA
Origin
China
HS Code
8544492100
Production Capacity
1000m/Month
Reference Price
$ 2.67 - 2.70

Product Description

Hebei huatong wires&cables Group Co.,ltd.

Largest cable manufacture in north China

19 years export experience

With UL,TUV,KEMA,CE,BV,PSB,SABS,GL,NK,KR,ABS ..products certifications

ISO9001,ISO14001,OHSAS18001 system certifications

With authorities testing report

CNAS approval laboratory 
 

PRODUCT CONSTRUCTION

 

Conductor: 6 AWG through 1000 kcmil bare annealed copper per ASTM B3. Compact stranding per ASTM B496. Extruded Strand Shield (ESS): Extruded thermoset semi-conductor stress control layer over the conductor per ICEA S-93-639 and UL 1072.

 

Insulation: 115 mil Ethylene Propylene Rubber (EPR) insulation per ICEA S-93-639 and UL 1072.

Extruded Insulation Shield (EIS): Thermoset semi-conducting polymeric layer, free stripping from the insulation per ICEA S-93-639 and UL 1072.

 

Shield: 5 mil annealed bare copper tape with 25% overlap.

 

Grounding Conductor(s): Three split Class B stranded bare annealed copper ground conductors sized in accordance with UL 1072 and NEC Article 250.

 

Armor: Impervious, continuously welded and corrugated aluminum alloy sheath per UL 1072 and 1569. Meets grounding requirements of NEC Article 250.

 

Jacket: Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), yellow. Low-temperature performance meets ASTM D746 brittleness temperature at or below -40ºC.

 

APPLICATIONS

Variable Frequency Drives: 3-conductor CCW armored cables with three symmetrical grounding wires are the preferred wiring method for use with AC motors controlled by pulse-width modulated inverters in VFD applications.

 

For use in Class I, II and III, Divisions 1 and 2; or Class 1, Zones 1 and 2 hazardous locations per NEC Articles 501, 502, 503 and 505. For installation on metal racks, troughs, in raceways and cable trays, or secured to supports not more than six feet apart. For exposed and concealed work in wet or dry locations, directly buried or embedded in concrete. For use on feeders and branch circuits in industrial power distribution systems per NEC Articles 328 and 330.

 

FEATURES

Armor provides impervious barrier to moisture, gas and liquids.

The strand shield, EPR insulation and insulation shield are extruded in one operation.

The EPR insulation system has outstanding corona resistance and high dielectric strength, and it provides electrical stability under stress. Meets cold impact test at -40ºC.

 

COMPLIANCES

Industry: UL Type MV-105. UL Type MC-HL, XHHW-2, CT USE, SUN RES, DIR BUR -40ºC, FT4.

UL Listed Marine Shipboard, American Bureau of Shipping (ABS) Listed for CWCMC.

 

Design Adherence:

ICEA S-93-639/WC74, 5-46 kV Shielded Power Cable.

AEIC CS8 Specification for Shielded Power Cable, 5-46 kV.

UL 1072 Medium-Voltage Power Cables.

UL 1569 Metal Clad Cables.

UL 2225 Cables and Cable Fittings for Use in Hazardous Locations.

UL 1309 Marine Shipboard Cable.

UL C68.3 Flame Tests: ICEA T-29-520 (210,000 BTU/hr). IEEE 383 (70,000 BTU/hr).

UL FT4.

IEEE 1202 (70,000 BTU/hr).

UL 1072. IEC 60332-3 Category A.

 

Size (AWG or Kcmil)No. of StrandsInsul. Thick. (Mils)Nom. Diam. Over ArmorPVC Jkt.Nom. Diam. Over PVC Jkt.Copper Phase Conductors
Copper Grounding Conductor (AWG)Weight (lbs./1000 ft.)Ampacity
(Inches)Thick (Mils)(Inches)NetCopperIn AirDirect Burial
5000 VOLTS - 133% INSULATION LEVEL or 8000 VOLTS - 100% INSULATION LEVEL
471151.51601.653 X #101418616115150
271151.64601.783 X #101731860154190
1191151.69601.823 X #819781074180215
1/0191151.78601.913 X #822591290205245
2/0191151.92602.053 X #826261556240280
4/0191152.15602.283 X #736502344320360
250371152.23602.363 X #740602759355395
350371152.45752.613 X #650453713440475
500371152.75752.923 X #571375191545570
750611153.32853.53 X #4102687629685700
1000611153.76853.943 X #41305110070790785

 

C--L--X Type Mv-105 or Mc-Hl - 750 Mcm AWG - Yellow Jacket 3/C 500mcm Power Cable
 

C--L--X Type Mv-105 or Mc-Hl - 750 Mcm AWG - Yellow Jacket 3/C 500mcm Power CableC--L--X Type Mv-105 or Mc-Hl - 750 Mcm AWG - Yellow Jacket 3/C 500mcm Power CableC--L--X Type Mv-105 or Mc-Hl - 750 Mcm AWG - Yellow Jacket 3/C 500mcm Power CableC--L--X Type Mv-105 or Mc-Hl - 750 Mcm AWG - Yellow Jacket 3/C 500mcm Power CableC--L--X Type Mv-105 or Mc-Hl - 750 Mcm AWG - Yellow Jacket 3/C 500mcm Power CableC--L--X Type Mv-105 or Mc-Hl - 750 Mcm AWG - Yellow Jacket 3/C 500mcm Power CableC--L--X Type Mv-105 or Mc-Hl - 750 Mcm AWG - Yellow Jacket 3/C 500mcm Power CableC--L--X Type Mv-105 or Mc-Hl - 750 Mcm AWG - Yellow Jacket 3/C 500mcm Power Cable

 