El modelo | 400V / 50Hz / 1500RPM | Motor diesel Perkins. | Alternador | |||||
Salida standby | Salida de la Prime | El modelo | El cilindro | El consumo de combustible | Marca | |||
KVA. | KW | KVA. | KW | (L/H) @ Carga completa | ||||
P-10 | 10 | 8 | 9 | 7 | 403A-11G1/8.6KW | 3L | 2.6 | PI 044E/10KVA. |
P-14 | 14 | 11 | 13 | 10 | 403A-15G1/12.2KW | 3L | 3.48 | PI 044F/12, 5 KVA. |
P-17 | 17 | 14 | 15 | 12 | 403A-15G2/14KW | 3L | 3.5 | PI 044G//15KVA. |
P-22 | 22 | 18 | 20 | 16 | 404A-22G1/18.7KW | 4L | 5.3 | PI 144D//20KVA. |
P-30 | 30 | 24 | 27 | 22 | 404D-22TG/25, 2KW | 4L | 6.7 | PI 144F/27, 5 KVA. |
P-33 | 33 | 26 | 30 | 24 | 1103A-33G/28, 2KW | 3L | 6.98 | PI 144G/30KVA. |
P-50 | 50 | 40 | 45 | 36 | 1103A-33TG1/42.2KW | 3L | 10.6 | PI 144K/42, 5 KVA. |
P-66 | 66 | 53 | 60 | 48 | 1104A-44TG1/59.6KW | 4L | 14.8 | UCI224E/60KVA. |
P-88. | 88 | 70 | 80 | 64 | 1104A-44TG2/73.4KW | 4L | 18.4 | UCI224G/85KVA. |
P-110 | 110 | 88 | 100 | 80 | 1104C-44TAG2/93.6KW | 4L | 20.5 | UCI274C/100KVA. |
P-150 | 150 | 120 | 135 | 108 | Un-70TG1/1191106KW | 6L | 29.9 | UCI274E/140KVA. |
P-165 | 165 | 132 | 150 | 120 | Una etiqueta2/1361106-70KW | 6L | 33.4 | UCI274F/160KVA. |
P-176 | 176 | 141 | 160 | 128 | Una etiqueta3/163 1106-70, 9 | 6L | El 41, 6 | UCI274F/160KVA. |
P-200 | 200 | 160 | 180 | 144 | Una etiqueta3/163 1106-70, 9 | 6L | El 41, 6 | UCI274G/182KVA. |
P-220 | 220 | 176 | 200 | 160 | Una etiqueta4/1741106-70KW | 6L | 45.8 | UCI274H/200KVA. |
P-250 | 250 | 200 | 225 | 180 | 1506A-E88TAG2/218KW | 6L | 48.6 | UCDI274J/230KVA. |
P-275 | 275 | 220 | 250 | 200 | 1506A-E88TAG3/239KW | 6L | 50 | UCDI274K/250KVA. |
P-303 | 303 | 242 | 275 | 220 | 1506A-E88TAG5/281KW | 6L | 60.2 | HCI444C/250KVA. |
P-330 | 330 | 264 | 300 | 240 | 1506A-E88TAG5/281KW | 6L | 64.9 | HCI444D/300KVA. |
P-385 | 385 | 308 | 350 | 280 | 2206C-E13TAG2/324KW | 6L | 70 | HCI444E/350KVA. |
P-440 | 440 | 352 | 400 | 320 | 2206C-E13TAG3/368KW | 6L | 82.7 | HCI444F/400KVA. |
P-500 | 500 | 400 | 455 | 364 | 2506C-E15TAG1/412KW | 6L | 95.6 | HCI544C/455KVA. |
P-550 | 550 | 440 | 500 | 400 | 2506C-E15TAG2/451KW | 6L | 106 | HCI544D/500KVA. |
P-660 | 660. | 528 | 600 | 480 | 2806C-E18TAG1A/532KW | 6L | 126, 6 | HCI544E/600KVA. |
P-700 | 700 | 560 | 650 | 520 | 2806A-E18TAG2/584KW | 6L | 129, 3 | HCI544F/670KVA. |
P-825 | 825 | 660. | 750 | 600 | 4006-23TAG2A/658KW | 6L | 152.3 | LVI634B/750KVA. |
P-880 | 880 | 704 | 800 | 640 | 4006-23TAG3A/705KW | 6L | 171.8 | HCI634G/810KVA. |
P-1000 | 1000 | 800 | 900 | 720. | 4008TAG2A/899KW | 8L | 188 | HCI634H/940KVA. |
P-1100 | 1100 | 880 | 1000 | 800 | 4008TAG2A/899KW | 8L | 215, 2 | HCI634J/1000KVA. |
P-1375 | 1375 | 1100 | 1250 | 1000 | 4012-46TWG2A/1113KW | 12V | 258.1 | LVI634G/1250 KVA. |
P-1650 | 1650 | 1320 | 1500 | 1200 | 4012-46TAG2A/1331KW | 12V | 299 | PI734C/1550KVA. |
P-1875 | 1875 | 1500 | 1710 | 1368 | 4012-46TAG3A/1500KW | 12V | 370 | PI734ES/1730KVA. |
P-2000 | 2000 | 1600 | 1800 | 1440 | 4016-61TRG1/1648KW | 16V | 385 | PI734E/1900KVA. |
P-2200 | 2200 | 1760 | 2000 | 1600 | 4016-61TRG2/1774KW | 16V | 421 | PI734F/2080KVA. |
P-2500 | 2500 | 2000 | 2250 | 1800 | 4016-61TRG3/1975KW | 16V | 473 | PI734G/2200KVA. |
Principales normas | GB/T2820, ISO8528, IEC34, CE, EPA Tier4 |
El primer potencia de salida | A partir del 5KVA hasta 2500KVA. |
La tensión nominal |
120V/240V, 220/380V, 230V/400V, 254V/440V, etc.
Otro voltaje es opcional. |
Fase del generador y la conexión | Fase 3, 4, cable |
Frecuencia | 50Hz@1500rpm o 60Hz@1800rpm |
Alternador emocionado tipo | Sin escobillas, auto excitado o PMG opcional |
El aislamiento del alternador | Clase H |
La protección del alternador | IP21 ~ IP23 |
Regulación de voltaje | Control automático de la AVR de 1% |
La altitud sobre el nivel del mar | ≤1000 m. |
La temperatura del aire | ≤40°C |
Humedad relativa del aire | ≤ 90% |