Medium Voltage Cu/XLPE/Hcts/LSZH/Swa/LSZH, Power Cable (BS 7835)

Wire Core Material
Red Copper Wire
Certification
ISO, CCC, CE, RoHS, VDE
Model
Yjv;Yjy;Yjv22;Yjy23;Wdz-Yjy;Wdz-Yjy23
Brand
Feiya
Other Name
Na2xry/Na2xrh/N2xny/Naxcy/Yxc7V/Naxsy/Nyfgby
Other EU Type
RV / U-1000 R2V
Colors
Can Be Customized
Low Smoke Zero Halogan
LSZH, Lsoh, Ls0h, Lsfh, Ohls
Low Smoke Halogen Free
Can Be Customized
Fire Resistant
Can Be Customized
Chinese Nomenclature
VV/ Yjv/ Yjv22/ Yjv32
Aluminum EU Type
RV Al / U-1000 Ar2V
Material
PVC/PE Jacket
Operating Environment
Underground
Use Place
Power Transmission and Distribution
Other Service
Can Be Customized
Rated Voltage
0.6/1kv
OEM&ODM
Yes
Can Be Customized
-5 Degree Till +70 Degree
Transport Package
Rolls or According to Customers′ Request
Specification
Nominal Cross section Area: 1.5-300mm2; 1.5-400mm2
Trademark
Fengda
Origin
Tianjin, China
HS Code
8544421900
Reference Price
$ 0.01 - 9.00

Product Description

35kv Copper Conductor 133% Insulation 1/0 2/0 3/0 Size Level Mv-90/Mv-105 Urd Power Cable


1 Application:
  It is used to transmit and distribute power in power transmission and distribution systems of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable. Power cables for power networks, underground, outdoors and in cable ducting.

Standard:  BS6622, BS EN/IEC 60228,IEC60502.2
Conductor : Class 2 stranded plain copper conductor to BS EN 60228:2005 (previously BS6360)
Conductor screen : Semiconducting material
Insulation:  XLPE (Cross-Linked Polyethylene) Type GP8 to BS7655
Insulation Screen : Semi-conducting material
Metallic Screen:   Individual and overall copper tape screen to BS6622
Filler:  PET (Polyethylene Terephthalate) fibers
Separator:   Binding tape
Bedding:  PVC (Polyvinyl Chloride) Type TM1 to BS7655
Armoring:

Single Core: Aluminium Wire Armoured (AWA)
MultiCore: Steel Wire Armoured (SWA)
Sheath: PVC (Polyvinyl Chloride) Type TM1 to BS7655
Colour: Red or Black

2. Using features :Medium Voltage Power Cable Underground 11kv 15kv 33kv XLPE Power Cable

1. Rated voltage: Uo/U:3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
2. No. of core: Single-core or three cores.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. long-term is no more than 5 seconds). The highest temperature for a conductor is no more than 250ºC.
4. D.C. resistance of the conductor complies with the stipulations of 3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
5. The environment temperature should be no lower than 0oC when lay. Otherwise, it should be preheated.
6. The cable is laid without a horizontal drop limit.
7. Working Frequency Voltage Test: 3.5Uo/5min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
9. Minimum Bending Radius: Single core - Fixed: 15 x overall diameter;3 core - Fixed: 12 x overall diameter
(Single core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use of a former)
Note: The single-core armored cables are used for the D.C. system only. If used for the A.C. system, the magnetic isolation should be applied to the steel armor wires of non-magnetical materials that should be used.


3. Structure
Medium Voltage Cu/XLPE/Hcts/LSZH/Swa/LSZH, Power Cable (BS 7835)

 

 

 

Medium Voltage Cu/XLPE/Hcts/LSZH/Swa/LSZH, Power Cable (BS 7835)


Medium Voltage Cu/XLPE/Hcts/LSZH/Swa/LSZH, Power Cable (BS 7835) Medium Voltage Cu/XLPE/Hcts/LSZH/Swa/LSZH, Power Cable (BS 7835)

 

 

 
 

 

 

Power Cable

PNEUTEC.IT, 2023