Frame | MINAS A6SE, A6SG, A6SF | MINAS A6N | MINAS A6B | ||
Input
power |
Main
circuit |
A-D | 1-phase, 3-phase, 200-240V (+10%, -15%), 50/60Hz | ||
E, F | 3-phase, 200-240V (+10%, -15%), 50/60Hz | ||||
Control
circuit |
A, B, C,
D, E, F |
1-phase, 200-240V (+10%, -15%), 50/60Hz | |||
Operating conditions | Ambient temperature | 0-55°C, storage temperature: -20 to +65°C (max. temperature 80°C for 72 h) | |||
Ambient humidity | Operation and storage: 20-85% RH (non-condensing) | ||||
Altitude | Max. 1000m above sea level | ||||
Vibration |
Max. 5.88m/s², 10-60Hz
(no continuous use at resonance frequency) |
||||
Control method | IGBT sinusoidal PWM | ||||
Encoder | Absolute | 23 bit (resolution 8388608ppr) | |||
Incremental | 23-bit, no battery required, set parameter Pr.015 to 1 | ||||
External feedback scale
(X5 connector) |
A/B phase | Initialization signal differential input (X5 connector only available for A6SF, A6N + A6B) | |||
Serial |
Compatible with Mitutoyo series AT500, ST771
(X5 connector only available for A6SF, A6N + A6B) |
||||
Control signals (multifunctional) | Inputs | 10 | 8 | 8 | |
Output points | 6 | 3 | 3 | ||
Analog signals (A6SF only) | Inputs |
3 input points:
(16-bit A/D: 1, 12-bit A/D: 2) |
|||
Output points | 2 | 2 | 2 | ||
Pulse signals | Inputs |
2 input points (opto coupler, line
receiver) |
|||
Output points |
4 output points
(line driver: Encoder A, B and Z-phase output or EXA/EXB and EXZ output, Open collector: Z-phase output or EXZ output) |
2 output points
(line driver: Encoder A-, B-phase output) |
|||
nterface | Realtime Express (RTEX) | Available | |||
EtherCAT | Available | ||||
USB | Interface to PC, etc. | ||||
RS232 |
1:1 communication (not for
A6SE) |
||||
RS485 |
1:n communication with up to
31 axes via host (FP series PLC) (not for A6SE) |
||||
Safety functions | IEC61800-5-2 (SIL3, STO), A6N and A6B also available without safety function | ||||
Front panel |
5 buttons (MODE, SET, UP,
DOWN, SHIFT), LED (6 digits) |
2 rotary switch, LEDs for operation indicator | |||
Regeneration |
For frame A, B: only external braking resistor,
for frame C to F: built-in braking resistor (external braking resistor also possible) |
||||
Dynamic brake | For frame A to F: built in | ||||
Control mode |
› Position control
› Velocity control › Torque control › Positioning/ velocity control › Postioning/ torque control › Rotation speed/torque control, › Full-closed control |
› Profile position mode (PP)
› Cyclic position mode (CP) › Cyclic velocity mode (CV) › Cyclic torque mode (CT) |
› Profile position mode (pp)
› Cyclic synchronous posi tion mode (csp) › Homing mode (hm) › Profile velocity mode (pv) › Cyclic synchronous velocity mode (csv) › Torque profile mode(tq) › Cyclic synchronous torque mode (cst) |