Model
|
SUN-5K-SG01LP1
|
SUN-6K-SG01LP1
|
SUN-7.6K-SG01LP1
|
SUN-8K-SG01LP1
|
Battery Input Data
|
Battery Type
|
Lead-acid or Lithium-ion
|
Battery Voltage Range (V)
|
40~60V
|
Max. Charging Current (A)
|
120A
|
135A
|
190A
|
190A
|
Max. Discharging Current (A)
|
120A
|
135A
|
190A
|
190A
|
Charging Curve
|
3 Stages / Equalization
|
External Temperature Sensor
|
Optional
|
Charging Strategy for Li-Ion Battery
|
Self-adaption to BMS
|
PV String Input Data
|
Max. DC Input Power (W)
|
6500W
|
7800W
|
9880W
|
10400W
|
PV Input Voltage (V)
|
370V (100V~500V)
|
MPPT Range (V)
|
125V-425V
|
Start-up Voltage (V)
|
150V
|
PV Input Current (A)
|
11A+11A
|
22A+11A
|
22A+22A
|
22A+22A
|
No.of MPPT Trackers
|
2
|
No.of Strings Per MPPT Tracker
|
1+1
|
2+1
|
2+2
|
2+2
|
AC Output Data
|
Rated AC Output and UPS Power (W)
|
5000W
|
6000W
|
7600W
|
8000W
|
Max. AC Output Power (W)
|
5500W
|
6600W
|
8360W
|
8800W
|
Peak Power (off grid)
|
2 times of rated power, 10 S
|
AC Output Rated Current (A)
|
20.8A
|
25A
|
31.7A / 33A
|
33.4A / 35A
|
Max. AC Current (A)
|
22.9A
|
27.5A
|
34.9A / 36.3A
|
36.7A / 38.5A
|
Max. Continuous AC Passthrough (A)
|
35A
|
40A
|
50A
|
50A
|
Output Frequency and Voltage
|
50 / 60Hz;208Vac (2 / 3 phase), 230Vac (single phase)
|
Grid Type
|
Single Phase
|
Current Harmonic Distortion
|
THD<3%(Linear load<1.5%)
|