China Manufacturers & Suppliers Direct Supply Regenerative Side Channel Blowers and Ring Vacuum Pumps

Model NO.
GHBH D73 34 1R3
Pressure
Medium Pressure
Certification
RoHS, ISO, CE, CCC
Stage
Single-Stage
Phase
Three-Phase
Frequency
50/60Hz
Operation Life
20, 000 Hours
Installation Method
Vertical or Horizontal
Features
Oil-Free, Maintenance-Free, Low-Noise, Long Life
Bearing
SKF/NSK
Insulation Class
F
Protection Level
IP55
Color
Golden/Silver
Product Name
Side Channel Blower
Transport Package
Standard Export Package
Specification
0.73HP air blower
Trademark
Goorui
Origin
China
HS Code
8414100020
Production Capacity
5000 Pieces/Month
Package Size
360.00cm * 315.00cm * 347.00cm
Package Gross Weight
15.000kg
Reference Price
$ 72.00 - 90.00

Product Description


China Manufacturers & Suppliers Direct Supply Regenerative Side Channel Blowers and Ring Vacuum Pumps
-- Technical Parameter
Product Name China Manufacturers & Suppliers of Side Channel Blowers and Vacuum Pumps
Model No. GHBH D73 34 1R3
Frequency 50Hz 60Hz
Rated Power 0.55kW 0.63kW
Rated Voltage 200-240△/345-415Y(V) 220-275△/380-480Y(V)
Rated Current 2.8△/1.6Y(A) 3.0△/1.7Y(A)
Max Airflow 110m³/h 140m³/h
Max Vacuum -110mbar -110mbar
Max Pressure 120mbar 120mbar
Sound 55db(A) 58db(A)
Weight 12kg 12kg
China Manufacturers & Suppliers Direct Supply Regenerative Side Channel Blowers and Ring Vacuum Pumps
China Manufacturers & Suppliers Direct Supply Regenerative Side Channel Blowers and Ring Vacuum Pumps
China Manufacturers & Suppliers Direct Supply Regenerative Side Channel Blowers and Ring Vacuum Pumps

--Product Features
GOORUI Side channel blowers are maintenance-free :
·External, permanently lubricated bearings
·Contactless rotating impellers
·Fan-cooled motors

GOORUI Side channel blowers are user-friendly :
·Weight-optimised design through aluminum pressure casting parts
·Possibility for a vertical or horizontal installation
·Suitability for converter operation

GOORUI Side channel blowers are environmentally friendly :
·Oil-free operation
·Low energy requirement
·Low noise emission

GOORUI Side channel blowers can be used world-wide :
·50/60Hz voltage range motors of the Iso class F
·Protection type IP55 with an integrated thermal protection switch (standard)
·CE, TUV, RoHS, CCC and ISO9001 certifications

--Performance Curves

China Manufacturers & Suppliers Direct Supply Regenerative Side Channel Blowers and Ring Vacuum Pumps --Dimensions
China Manufacturers & Suppliers Direct Supply Regenerative Side Channel Blowers and Ring Vacuum Pumps --Detailed Photos
China Manufacturers & Suppliers Direct Supply Regenerative Side Channel Blowers and Ring Vacuum Pumps China Manufacturers & Suppliers Direct Supply Regenerative Side Channel Blowers and Ring Vacuum Pumps China Manufacturers & Suppliers Direct Supply Regenerative Side Channel Blowers and Ring Vacuum Pumps --Applications
China Manufacturers & Suppliers Direct Supply Regenerative Side Channel Blowers and Ring Vacuum Pumps China Manufacturers & Suppliers Direct Supply Regenerative Side Channel Blowers and Ring Vacuum Pumps --Accessories

--Installation Instructions

INSTRUCTIONS
1. It should be placed in a relatively stable place, and the surrounding environment should be clean, dry and ventilated.
2. The direction of rotation of the impeller must be consistent with the direction of the pointed tip marked on the fan cover.
3. When working, the working pressure should not be greater than 8 kPa, so as to avoid excessive heat generation of the air pump and damage to the air pump caused by motor overcurrent.
4. It is strictly forbidden for solid, liquid and corrosive gas to enter the pump body.
5. The filters and silencers at both ends of the air inlet and outlet should be cleaned in time according to the situation to avoid clogging and affecting use.
6. The external connection of the air inlet and outlet must be connected by a hose (rubber tube, plastic spring tube).

PRECAUTIONS
1. Flat washers and spring washers must be used to tighten the screws.
2. It is best to use rubber buffer rubber to bear the weight of the vortex air pump, especially the high-power vortex air pump, which is indispensable.
3. For some occasions that require noise, a silencer can be installed to reduce the noise (generally down, about 5 dB), the silencer is installed at the end of the inlet duct or outlet duct.
4. For some occasions with high requirements for noise, you can add a layer of silencer cotton according to the conditions of the machine itself to meet the noise requirements on site. For details, please consult our customer service.
5. When using silencing cotton to silence the sound, pay attention to the distance between the vortex air pump and the box, pay attention to the ventilation and heat dissipation of the vortex air pump, and pay attention to using rubber cushioning to bear the weight of the vortex air pump. According to the picture, you need to consult customer service.
6. The air inlet and outlet of the vortex air pump For pipe connection, hose connection should be used to isolate vibration.

 

PNEUTEC.IT, 2023