FD1X4S Technical Specifications Table | |||||
![]() |
|||||
Model | FD1X4S Technical Specifications Table | ||||
FD114S-CB-005 | FD124S-CB-005 | FD134S-CB-005 | FD144S-CB-005 | ||
Main supply voltag e | 24VDC-70VDC | ||||
Rated
output current |
Rated curren(t rms) | 5Arms | 15Arms(Up to 12Arms without auxiliary radiator) | 25Arms(Up to 20Arms without auxiliary radiator) | 40Arms(Up to 30Arms without auxiliary radiator) |
Peak current (PEAK) | 12AP | 48AP | 80AP | 120AP | |
Feedback signal | 2500P/R(Incremental differential 5V encoder),Magnetoelectric encoder,absolute value encoder(Apply to FD1X4S-LB-000) | ||||
Brake power supply | The motor brake power supply is not provided, and an external power supply device is required for the motor brake | ||||
Brake chopper | Via wiring an external brakingresisto(r mainly in quick start and stop application),brake chopper threshold is 73V(Adjustable via software). | ||||
Brake chopper | Via wiring an external braking resisto(r mainly in quick start and stop application),brake chopper threshold is 73V(Adjustable via software). | ||||
Brake chopper threshold | DC73V ± 2V(Default value, Adjustable via software) | ||||
Over-voltage alarming threshold | DC83V ± 2V | ||||
Under-voltage alarming threshold | 18V±2V | ||||
Cooling method |
Natural air cooling Note:The continuous output current of FD124S, FD134S, FD144S are 15Arms, 25Arms and 40Arms respectively.
(Need Oxidized black 6063 on aluminum cooling. The size of auxiliary radiator is 300mm*300mm*10mm) |
||||
Weight(KG) | 0.3 | 0.3 | 0.6 | 0.9 | |
General functions | Input specification | External pulse input control; 8-segment position can be controlled using DIN signal; Internal paramater of communication setting control | |||
Input function | Low-pass filte(r Set by internal prameter),S-curve smooth filter(Set by internal parameters in mode 1) | ||||
Output specification | Pulse+Direction,CCW+CW,A phase+B phase(3.0-30V ,Maximum 500 KHz) | ||||
Impulsive control | Differential transmission mode:up too 4MHz,Open collector transmission mode:500 KHz | ||||
Output function | Setting range: Gear factor:-32767 ,Gear divider:1!32767 ,1/50 ≤|Gear factor/Gear divider|≤50 | ||||
RS232 | Set by internal parameter | ||||
Protection function | 0-100 %(Set by internal parameter) | ||||
Canopen | Low-pass filte(r Set by internal parameter) | ||||
Operation Environment | peration temperature | 0-40 ºC | |||
Storage temperature | 10 ºC-70 ºC | ||||
Humidity(non-condension) | 5~95% | ||||
Protection class | IP20 | ||||
Installation environment | Installed in a dust-free, dry and lockable environmen(t such as in a electrical cabinet) | ||||
Installation mode | Install vertically or horizontally | ||||
Height | Rated working altitude at 1000m or below,Above 1000m: Drecreasing 1.5% per 100m rise,maximum altitude 4000m | ||||
Atmospheric pressure | |||||
Note: FD1X4S-LA-000, FD1X4S-CA-000, FD1X4S-EA-000 do not provide motor holding brake power supply, and the motor holding brake needs an external power supply device |