| Product Model | HHG1-1/032F-22, 38 4A (SSR-DA) | HHG1-0/032F-06, 20 4A (SSR-DD) | |
| Description | Miniature Double-parallel PCB SSR | Miniature Double-parallel PCB SSR | |
| Control Voltage | 3-32VDC | ||
| Control Current | 6-35mA | ||
| Turn-on Voltage | 3VDC | ||
| Turn-off Voltage | 1VDC | ||
| Reverse Voltage | 32VDC | ||
| Load Voltage | 22: 30-240VAC, 38: 40-440VAC | 06: 12-60VDC, 11: 12-110VDC, 20: 12-200VDC | |
| Load Current | 3A, 4A | ||
| Transient Voltage | 22: 600VAC, 38: 900VAC | 06: 100VDC, 11: 110VDC, 20: 220VDC | |
| On-state Voltage Drop | less than 1.6VAC | less than 1.2VDC | |
| ON-OFF Time | less than or equal to 10mS | less than or equal to 5mS | |
| Off-state Leakage Current | less than or equal to 10mA | less than or equal to 5mA | |
| Dielectrics Voltage-resistance | equal to or greater than 1500VAC | ||
| Insulation Resistance | 500MΩ 500VDC testing | 500MΩ 500VDC testing | |
| Ambient temperature | minus 30 centigrade to 80 centigrade | ||
| Dimensions | 35L*27W*17H | ||
| Installation | PCB | ||
| Packing | Inner Box(PCS) | 10/Foam board | |
| Outer CTN(PCS) | 300 | ||
| CTN Size | 380*215*175mm | ||
| Weight | about 34g/pcs G. w: 11.5kg N. W: 10.5kg | ||
| Remarks |
1. When the load current is greater than 10A, a radiator is necessary;
When the load current is greater than 80A, fan is necessary. |
||
|
2. When controlling inductive load, a varistor is necessary
and its voltage could be 1.6-1.9 times of load voltage |
|||