De550e3 400kw/500kVA 50Hz Open Silent Type Diesel Generator Set

Model NO.
DE550E3
Output Type
AC Three Phase
Speed
1500 Rpm
Conditions of Use
Land Use
Usage
Common Units
Landuse Type of Unit
Low Noise Automation Type
Excitation Mode
AC Rotating Exciter
Emission
EU Iiia
Governor Type
Electronic Adem A4
Transport Package
Wrapped Film Packaging
Trademark
ML MY POWER
Origin
China
HS Code
850212000
Production Capacity
500PCS/Year
Reference Price
$ 99,090.00 - 99,180.00

Product Description

C15
Diesel   Generator   Sets
Standby   &   Prime:   50   Hz  
 
Engine   Model   C15   ACERT   In-line   6,   4-cycle   diesel
Bore   x   Stroke 137mm   x   171mm   (5.4in   x   6.8in)
Displacement 15.2   L   (928   in³)
Compression   Ratio 16.1:1
Aspiration Turbocharged   Air-to-Air   Aftercooled
Fuel   Injection   System MEUI
Governor Electronic   ADEM™   A4
 
M o del Standby P rime Emission   Strat egy
DE550 E3 50  Hz 50  Hz EU IIIA
550   kVA,   440   ekW 500   kVA,   400   ekW

  PACKAGE   PERFORMANCE
Pe rformance Standb y P rime
Frequ ency 50  Hz 50  Hz
Gense t   Power   Rating 550   kVA 500   kVA
Genset   power   rating   with   fan  @ 0 .8 power factor 440   ekW 400   ekW
Emissions EU IIIA
Performance   Number EM1247 EM0430
Cool ing   System    
Radiator   air   flow   restriction   (system),   kPa   (in.   Water) 0.12   (0.48) 0.12   (0.48)
Radiator   air   flow,   m 3 /min   (cfm) 476   (16809) 476   (16809)
Engine   coolant   capacity,   L   (gal) 20.8   (5.5) 20.8   (5.5)
Radiator   coolant   capacity,   L   (gal) 34   (8.9) 34   (8.9)
Total   coolant   capacity,   L   (gal) 54.8   (14.4) 54.8   (14.4)
Inlet   Ai r    
Combustion   air   inlet   flow   rate,   m³/min   (cfm) 35.9   (1269.4) 35.0   (1237.4)
Max.   Allowable   Combustion   Air   Inlet   Temp,   °C   (°F) 48   (118) 47   (116)
Exhaust   Syst em    
Exh aust   stack   gas   temperature , ° C  (° F ) 484.2   (903.6) 471.3   (880.4)
Exh aust   gas   flow   rate , m ³/ min  ( cfm ) 95.8   (3383.6) 91.4   (3226.7)
Exhaust   system   backpressure  ( maximum   allowable ), kPa  ( in   H 2 O) 10.0   (40.0) 10.0   (40.0)
Heat   Rejecti on    
Heat   rejection   to   jacket   water,   kW   (Btu/min) 165   (9374) 153   (8681)
Heat   rejection   to   exhaust   (total)   kW   (Btu/min) 426   (24213) 400   (22769)
Heat   rejection   to   aftercooler,   kW   (Btu/min) 126   (7171) 118   (6712)
Heat   rejection   to   atmosphere   from   engine,   kW   (Btu/min) 66   (3767) 59   (3366)
 
Emissions   ( Nominal) 2 S tandby P rime
NOx,   mg/Nm³   (g/hp-hr) 1634.6   (3.5) 1470.6   (3.2)
CO,   mg/Nm³   (g/hp-hr) 279.8   (0.6) 260.8   (0.6)
HC,   mg/Nm³   (g/hp-hr) 10.1   (0.0) 13.0   (0.0)
PM,   mg/Nm³   (g/hp-hr) 11.5   (0.0) 12.8   (0.0)
 
Alternator 50   Hz
Voltages 4 15V 4 00V 3 80V
Motor   starting   capability   @   30%   Voltage   Dip 1391   skVA 1291   skVA 1165   skVA
Current SB:   765A,   PP:   696A SB:   794A,   PP:   722A SB:   830A,   PP:   722A
Frame   Size A2985L4 A2985L4 A2985L4
Excitation S E S E S E
Temperature   Rise SB:   163°C,   PP:   125°C SB:   163°C,   PP:   125°C SB:   163°C,   PP:   125°C

WEIGHTS   &   DIMENSIONS
Dim   "L "
mm   (in)
Dim   "W "
mm   (in)
Dim   "H "
mm   (in)
Dry   Weight
kg   ( lb )
3830   (151) 1130   (44) 2255   (89) 3700   (8157)
Note :  General configuration not to be used for installation. See general dimension drawings for detail.

APPLICABLE   CODES   AND   STANDARDS:
AS1359,    C22.2   No100-04,   UL142,   UL489,   UL869,   UL2200,   NFPA37,   NFPA70,
NFPA99,   NFPA110,   IBC,   IEC60034-1,   ISO3046,   ISO8528,   NEMA   MG1-22,   NEMA   MG1-33,   2006/95/EC,   2006/42/EC,   2004/108/EC.
N ote :   Codes   may   not   be   available   in   all   model   configurations . Please consu lt   your   local   Cat   Dealer   representative   for   availability .                   
ST ANDBY : Output   available   with   varying   load   for   the   duration   of   the    interrup tion   of   the   normal   source   power . Average   power   output   is  70%   of the s tandby   power   rating . Typical   operation   is  200 hours   per   year ,    with   maximum expected usage of 500 hours per year.

PR IME : Output   available   with   varying   load   for   an   unlimited   time .  Average   power   output   is  70% of   the   prime   power   rating . Typical   peak demand   is 100% of prime rated ekW with 10% overload capability for emergency   use for a maximum of 1 hour in 12. Overload operation cannot   exceed   25 hours per year
RATINGS:  Rat ings   are   based   on   SAE   J 1349 standard   conditions .  These   ratings   also   apply   at   ISO 3046 standard conditions.

DEFINITIONS   AND   CONDITIONS
1.  For ambient and altit ude   capabilities   consult   your   Cat   dealer . Air   flow restriction  ( system ) is   added   to   existing   restriction   from   factory .
2.  Emissions   data   measurement   procedures   are consistent with those    described   in   EPA   CFR  40 Part  89, Subpart   D  & E   and   ISO 8 178-1 for  measuring   HC, CO, PM, NOx. Data shown is based on steady state operating   conditions   of  77° F , 28.42 in   HG   and   number  2  diesel fuel     with  35° API   and   LHV   of  18,3 90 BTU/lb. The nominal emissions data  shown   is subject to instrumentation, measurement, facility and engine to   engine   variations. Emissions data is based on 100% load and thus cannot be used to   compare   to   EPA   regulations   which   use   values based   on   a   weighted   cycle .
3.  Generator   temperature   rise   is   based   on a 40°C ambient per NEMA MG 1- 32.
 
De550e3 400kw/500kVA 50Hz Open Silent Type Diesel Generator Set
 
 

     
 
De550e3 400kw/500kVA 50Hz Open Silent Type Diesel Generator Set
 
 
 
 
 
                   
      
 
 

 

Diesel Generator

SUNFLAVOUR.CO.JP, 2023