Advantages of
X960 Real-Time PCR
1. CE, ISO certification;
2. LED light source and high-resolution CCD, extended service life, low background noise signal, and high work efficiency.
3. All samples collect fluorescence signals at the same time to ensure the consistency and accuracy of fluorescence collection;
4. The fastest heating and cooling speed can reach 5ºC/s, which effectively shortens the reaction time and effectively prevents non-specific amplification, which greatly saves the user's time;
5. The fully enclosed sample holder design can effectively avoid sample volatilization and ensure the safety of test samples;
6. Standard gold-plated heating module (C module, the general brand uses aluminum or silver-plated module)
7. The qPCR analysis software could be upgraded for free.
In conventional PCR, the amplified DNA product, or amplicon, is detected in an end-point analysis. In real-time PCR, the accumulation of amplification product is measured as the reaction progresses, in real-time, with product quantification after each cycle.
X960 Real-Time PCR system is a high-performance benchtop instrument giving you greater control of your experiment data. It delivers reliability, sensitivity, and accuracy, which is optimized to enable a broad range of quantitative PCR applications.
Model
|
X960
|
Channel Type B:
|
5 (Channel 5 reserved)
|
Reactions per run
|
96
|
Block Format
|
96-well 0.2-ml
|
Color Combinations
|
Up to 5
|
Light source
|
High brightness monochrome LED
|
Detector
|
Highly sensitive cold light CCD
|
Detection dynamic range
|
10°-1010
|
Sensitivity
|
Down to 1 copy
|
Reaction volume
|
15ul-100ul
|
Chemistry
|
All real-time PCR-based chemistries.Flexibility for chemistries with or without passive reference dye.
|
Excitation source
|
White LED
|
Excitation filters/colors
|
Channell: 470nm Channel2:525nm
|
Channels:585 nm Channel4:625nm
|
Detection filters/colors
|
Channell: 520 nm
|
Channel2: 570 nm
|
Kits & Reagent
|
Channels:620 nm Channel4: 675 nm
|
Channell: FAM/SYBR
|
Channel: VIC/HEX/JOE/TET/TAMRA/CY3
|
Channels: ROX/TEXRAD
|
Channel% CY5
|
Channels: CY5.5(Reserved/Customized)
|
Block Material
|
Peltier
|
Accuracy
|
±0.1ºC
|
Temp Uniformity
|
±0.4ºC(10 sec after reaching 95ºC)
|
±0.2ºC(10 sec after reaching 55 ºC)
|
Temp Range
|
0ºC-99ºC(Rt<30ºC)
|
Max. ramp rate
|
5 ºC/s
|
Gradient range
|
30ºC-99.9ºC
|
PC Operation system
|
WindowsXP/VISTA/Windows7/Windows8/Windows10,etc
|
X960 Operation system
|
Linux
|
CPU
|
A8 processor
|
Network
|
LAN /WIFI
|
Multiple control
|
Support
|
Applications Available
|
Gene Expression, Genotyping, Copy Number Variation, Protein Detection, MicroRNA, Pathogen Detection
|
Size(W*D*H)
|
592 x 440 x 280 mm
|
Innovative Optical Design
1. Two-channel (X960A) and five-channel (X960B) fluorescent detection system with an LED light source and high-resolution CCD.
2. The optical system automatically collects data from all wells during data acquisition at the same time.
3.X960 can discriminate up to five targets in a single reaction well.
4. The optical filter sets are designed to maximize fluorescence detection for specific dyes in specific channels. Compatible with different reagents and consumables.
Heal Force integrates research and development, manufacturing, sales, and service. It has a number of production plants that research and develop professional equipment, more than one thousand employees, and products throughout the world in more than 100 countries and regions. Likang International Trade Shanghai Co., Ltd is a sales and operation center under the group, which is committed to providing you with advanced medical equipment, laboratory instruments, and home Internet of things medical and health products.
Q: How many detection channels does the instrument have?
A: There are two models to choose from, X960A has two channels, and X960B has four channels plus one reserved channel.
Q: How many samples does the instrument do at one time?
A: The product is equipped with a 96-well module and can make up to 96 samples at a time.
Q: How long does the experiment result take?
A: The detection time of the instrument is related to the cycle program parameters used in the experiment.
Q: What items need to be prepared to use the instrument?
A: This product needs to be connected to a computer for use, and users need to prepare their own computer. There is no
requirement for computer configuration.
Q: How to judge whether the instrument is suitable for certain reagents or consumables?
A: Whether the reagents are applicable depends on whether the fluorescent dyes or probes used in the reagents correspond to
the channels of the instrument; applicable consumables are 0.2ml transparent, optical flat cap reaction single tube, eight-strip
tube, and 96 without a skirt or half skirt Orifice plate.
Q: How to get after-sale technical support?
A: Users can contact us via email or video for problems in the use of the instrument, and we will give feedback or solutions as soon as possible.