W50-T-P-DE (DC66P), W100-T-P-DE (DC88P) DC Contactors has been designed for direct current DC loads, particularly motors used on electric winches and electric vehicles.
- Motor Reversing DC Contactor
- Coil Voltage: 12Vdc or 24Vdc
- Paired Single Pole Double Throw (Double Pole, Changeover Contacts)
- Ideal for Marine Applications, such as, Bow Thrusters, Windless and Winches.
| Model |
W50-T-P-DE
(DC66P) |
W100-T-P-DE
(DC88P) |
| Photo |
|
|
| Coil Voltage | 12VDC, 24VDC, 48VDC, 72VDC etc | |
| Rated Voltage of Contact Circuit | 80VDC and below | |
| Rated Current | Continuous 50A, Intermittent 250A | Continuous 100A, Intermittent 500A |
| Dielectric Voltage Strength | 50Hz 1000V AC 1min | |
| Volt Drop of Main Contact | < 100mV | |
| Mechanical life | 100 thousand times | |
| Electric life | Continous 20 thousand times, Intermittent 2 thousand times | |
| Contact Form |
Double Pole, Changeover Contacts
(Paired Single Pole Double Throw) |
|
| Coil Power | 25-27W | 29-31W |
|
Typical Pull-In Time
(N/O Contacts to Close) |
<30ms | |
|
Typical Drop-Out Time
(N/O Contacts to Open) |
<50ms | |
| Pull-In Voltage (Coil at 20ºC) | <75%Us | |
| Drop-Out Voltage (Coil at 20ºC) | 5% - 40% | |
| Main stud terminals | M8 | |
| Feature | Waterproof, Heavy load for various Winches, Tarp motors, etc | |
| Wiring Diagram |
|
|
| Installation Diagram |
|
|