Specifications
S6100X Anesthesia system | |
Ventilation modes: | (V-CMV) IPPV, (P-CMV) PCV, PSV, (P-SIMV), (V-SIMV), SIGH, PRVC, MANUAL |
Graphical display: | P-T(pressure - time) |
F-T(flow - time) | |
V-T(volume - time ) | |
Lung function loop | |
ETCO2-T (End-tidal CO2 - time) | |
Alarm and protection | |
VT UPPER LIMIT
VT LOWER LIMIT |
5mL~2000mL
0mL~1595mL |
MV upper limit
MV lower limit |
0.1L/min~100L/min
0.0L/min~99.9L/min |
Respiration frequency upper limit
Respiration frequency lower limit |
2bpm~100bpm
0bpm~98 bpm |
FIO2 upper limit
FIO2 lower limit |
20%~100%
18%~98% |
Airway pressure upper limit
Airway pressure lower limit |
2cmH2O~100cmH2O
0cmH2O~98cmH2O |
Apnea | 20s~40s |
Oxygen concentration never lower than 25% when N2O start | |
Working conditions | |
Gas source | O2,N2O,AIR |
Pressure | 280kPa-600kPa |
Voltage | 100-240V |
Power frequency | 50/60Hz |
Input power | 80VA |
Vaporizer | |
|
1.Bigger screen than S6100PLUS.
15" LCD touch screen
shows all parameters clearly.
2.
Six oscillographs
are able to displayed at the same time.Waveform:P-T,P-V,F-T,V-T,ETCO2 -T, Lung function Loop.
3.
Multiple ventilation modes
meets different conditions including: (V-CMV)IPPV,(P-CMV)PCV,PSV,(P-SIMV),(V-SIMV),SIGH,PRVC,MANU
4.
Three Electronic flowmeters
and
Three mechinical flowmeters
work together.
5.
Electronic fresh gas mixer
is used in the system.
6.
Greater range of parameters
can suitable for Newborn baby over 1kg. Vt:10ml~1500ml;I:E:4:1~1:10
7.
Memory function
,
Patient's medical record
can be set and stored .Doctors can pre-set age and transfer the record to computer by VGA.
8.
Eight languages
can be chose:Chinese,English,Spanish,French,Russian,Turkish,German,Portuguese.
9.There are
four power sockets
. The Monitors don't need to find another power socket.
10.The
central brake
and
two rounds of brake
can be chose as you want.
About us
Superstar med is leading manufacturer of ICU product, mainly focus on Anesthesia machine,Ventilator machine, neo-CPAP, Veterinary Anesthesia machine and Sleep therapy system.
neo-CPAP----
To nourish and support the infant breathing for neonatal(0-28days) and Child (0-14years old),widely used in neonatal intensive care units(NICU),delivery room and other
departments. Use along with the incubator.
Nitrous oxide Sedation system
---- To reduce the pain and anxiety for patients. Widely used in dental department , Endo gastrointestinal department, obstetrics department and other departments .
According to international guideline, nitrous oxide sedation is considered a safe and effective dental sedation technique, and recommended as a first-line option.