Item | Parameters or indicators | |||
Measuring Range | -0.1MPa...0kPa ~ 10kPa…100MPa | |||
Overload pressure | under 10MPa ≤ 2 times of full scale | 10MPa and above ≤ 1.5 times of full scale | ||
Pressure type | G (gauge pressure), A (absolute pressure), S (sealed gauge pressure) | |||
Accuracy | 0.1 (customized) | 0.25 (typ.) | 0.5 (max) | |
Long Term Stability | ±0.1% FS/year (typical) | ±0.2% FS/year (maximum) | ||
Zero Temperature Drift | ±0.03%FS/ ºC (≤100kPa) | ±0.02%FS/ ºC ( > 100kPa) | ||
Sensitivity Temperature Drift | ±0.03%FS/ ºC (≤100kPa) | ±0.02%FS/ ºC ( > 100kPa) | ||
Temperature Compensation | 0 ºC ~ 50 ºC (≤100kPa) | -10 ºC ~ 70 ºC ( > 100kPa) | ||
Medium Temperature | -40 ºC ~ 80 ºC | |||
Power Supply | 12VDC ~ 30VDC | |||
Output Signal | 4mA ~ 20mA | 0V ~ 10V ( can be customized ) | ||
Load Resistance | Current type: ≤(U-12)/0.02(Ω) | |||
Protection Level | IP65( customizable IP68) |