Range | MPa | -0.1MPa…0kPa ~ 10kPa…100MPa | ||
Form of pressure | G , A , S | |||
Output signal (mA) |
4 mA
~
20 mA (HART protocol can be superimposed),RS485 (4 mA
~
20 mA signal can be output at the same time)
0 ~ 5V (0 ~ 10) three wire system |
|||
Accuracy level | 0.1(customized) | 0.25 | 0.5 | |
Nonlinear (FS%) | ≤0.1 | ≤0.2 | ≤0.4 | |
Hysteresis, repeatability (FS%) | ≤0.05 | ≤0.05 | ≤0.1 | |
Zero and sensitivity temperature drift (FS / ºC) | ≤0.015 | ≤0.03 | ≤0.05 | |
Long term stability (FS / year) | ≤0.1 | ≤0.2 | ≤0.5 | |
Operating voltage (VDC) | +15 ~ + 30 (calibration value is + 24) | |||
Field display | 4Bit LED or LCD | |||
Compensation temperature (ºC) | 0 ~ +50 ( ≤200kPa ), -10 ºC ~ 70ºC (> 200kPa ) | |||
Operating temperature (ºC) | -40 ~ + 85, - 20 ºC ~ 60 ºC (explosion proof) | |||
Overload capacity (%) | ≤200 (< 10MPa ); ≤150 ( ≥100MPa ) | |||
Load resistance (Ω) |
R=
(
U-12.5
)
/0.02-RD
Where: u is the power supply voltage and RD is the internal resistance of the cable |
|||
Response time (10% - 90%) ms | ≤1 | |||
Measuring medium | Fluids compatible with 304, 316L or ceramics | |||
Diaphragm material | 316L, titanium alloy or ceramic are available | |||
Shell material | 3046063 aluminum alloy | |||
Interface | 304326l optional | |||
Explosion proof grade | Intrinsically safe: ex D IIC T5 GB | |||
Protection level | IP66 |
Model | Features | Pattern |
CYB0511 |
1. Optional range: - 0.1MPa…0kPa
~
10kPa…100MPa
2. The whole series of thread can be customized 3. Pressure interface material can be customized 4. Shock resistant design, damping is available |
![]() |
CYB05X3X4 | Type of pressure transmitter | ||||||||||||||
Range | The measuring range is -0.1MPa...0MPa ~ 0.01MPa…100MPa | ||||||||||||||
Xxn | In kPa, the first two digits XX value is multiplied by the n-square of 10, and N is the third digit value. | ||||||||||||||
Code name | Form of pressure | ||||||||||||||
G | Gauge pressure type | ||||||||||||||
A | Absolute pressure type | ||||||||||||||
D | Differential pressure type | ||||||||||||||
S | Sealed gauge pressure type | ||||||||||||||
Code name | Supply voltage | ||||||||||||||
U 1 | 24VDC | ||||||||||||||
U 2 | 12VDC | ||||||||||||||
U 3 | 5VDC | ||||||||||||||
U 4 | 3VDC ( 3.3VDC ) | ||||||||||||||
U 5 | Other power supply modes | ||||||||||||||
|
Code name | output signal | |||||||||||||
E 1 | 4mA ~ 20mADC | ||||||||||||||
E 2 | 0mA ~ 10mADC | ||||||||||||||
E 3 | 0mA ~ 20mADC | ||||||||||||||
V 1 | 1VDC ~ 5VDC | ||||||||||||||
V 2 | 0VDC ~ 5VDC | ||||||||||||||
V 3 | 0VDC ~ 10VDC | ||||||||||||||
V 4 | 0.5VDC ~ 4.5VDC | ||||||||||||||
V 5 | Other voltage output | ||||||||||||||
R 4 | RS485 communication interface | ||||||||||||||
H | HART protocol communication | ||||||||||||||
II | I 2 C protocol communication | ||||||||||||||
|
Code name | Shape interface | |||||||||||||
Electrical interface | Mechanical interface | ||||||||||||||
Housman socket (J1) | G | ||||||||||||||
Aviation socket (J2) | G | ||||||||||||||
Waterproof joint (J3) | G1 | ||||||||||||||
Outlet liquid level (J4) | M20×1.5 | ||||||||||||||
Others (J5) | Others (direct marking) | ||||||||||||||
|
Code name | Additional features | |||||||||||||
M 1 | 4Bit LCD digital display meter (only 4mA ~ 20mADC output) | ||||||||||||||
M 2 | 4Bit LED digital display meter (only 4mA ~ 20mADC output) | ||||||||||||||
d | Flameproof Exd IICT5 | ||||||||||||||
i | Intrinsically safe ex IA II CT6 | ||||||||||||||
QT | Other functions | ||||||||||||||
CYB0511 [102] G U 1 E 1 J5G ½ M 1 Complete model and specification |