Range | MPa | -0.1MPa…0kPa ~ 10kPa…100MPa | ||
Type of pressure | G , A , S | |||
Output signal | 4 ~ 20mA | |||
0 ~ 5V(0 ~ 10V) three-wire system | ||||
Accuracy level | 0.1 ( customized ) | 0.25 | 0.5 | |
Nonlinearity ( FS% ) | ≤0.1 | ≤0.2 | ≤0.4 | |
Hysteresis , Repeatability ( FS% ) | ≤0.05 | ≤0.05 | ≤0.1 | |
Zero point and sensitivity temperature drift ( %FS/ ºC ) | ≤0.015 | ≤0.03 | ≤0.05 | |
Long-term stability(%FS/year) | ≤0.1 | ≤0.2 | ≤0.5 | |
Working voltage ( VDC ) | +15 ~ +30 ( the calibration value is + 24 ) | |||
Compensation temperature ( ºC ) | 0 ~ +50 ( ≤200kPa ), -10 ºC ~ 70 ºC (> 200kPa ) | |||
Working temperature ( ºC ) | -40 ~ +85 | |||
Overload capacity ( % ) | ≤200 (< 10MPa ); ≤150 ( ≥100MPa ) | |||
Load resistance ( Ω ) |
R=
(
U-12.5
)
/0.02-RD
Among them: U is the power supply voltage, RD is the internal resistance of the cable |
|||
Response time ( 10% ~ 90% ) ms | ≤1 | |||
Measuring medium | Fluids compatible with 304, 316L or ceramics | |||
Diaphragm material | 316L , Titanium alloy or ceramic optional | |||
Shell material | 304 , 316L | |||
Interface | 304 , 316L is optional | |||
Protection level | IP65 ( IP68 customizable ) |
Horsman connector | ||
Model | Features | Pattern |
CYB4211 |
1
,
Standard integrated Hosman connector
;
2 , Series recommended thread optional ; 3 , Pressure interface material can be customized ; 4 , Protection grade IP65. |
![]() |
CYB4212 |
1
,
Housing combination Horsman connector
;
2 , Series recommended thread optional ; 3 , Pressure interface material can be customized ; 4 , Protection grade IP65. |
![]() |
CYB4213 |
1
,
RS485 output
2 , Series recommended thread optional ; 3 , Pressure interface material can be customized ; 4 , Protection grade IP65. |
![]() |
CYB 4220 |
1
,
High temperature heat sink
,
Hosman connector
;
2 , Medium temperature range -40 ~ 150 ºC ; 3 , Number of heat sinks3 , 6 , 9 is optional ; 4 , Pressure interface material can be customized ; 5 , Protection grade IP65. |
![]() |
CYB42X 3 X | Pressure transmitter type | |||||||||
Range | Measuring range:-0.1MPa…0MPa ~ 0.01MPa…100MPa | |||||||||
xxn | Unit: kPa , The first two digit XX value is multiplied by the n-square of 10, and N is the third digit value. | |||||||||
Code name | Form of pressure | |||||||||
G | Gauge pressure type | |||||||||
A | Absolute pressure type | |||||||||
D | Differential pressure type | |||||||||
S | Pressure gauge seal type | |||||||||
Code name | Supply voltage | |||||||||
U 1 | 24VDC | |||||||||
U 2 | 12VDC | |||||||||
U 3 | 5VDC | |||||||||
U 4 | 3VDC ( 3.3VDC ) | |||||||||
U 5 | Other power supply methods | |||||||||
|
Code name | output signal | ||||||||
E 1 | 4mA ~ 20mADC | |||||||||
E 2 | 0mA ~ 10mADC | |||||||||
E 3 | 0mA ~ 20mADC | |||||||||
V 1 | 1VDC ~ 5VDC | |||||||||
V 2 | 0VDC ~ 5VDC | |||||||||
V 3 | 0VDC ~ 10VDC | |||||||||
V 4 | 0.5VDC ~ 4.5VDC | |||||||||
V 5 | Other voltage output | |||||||||
R 4 | RS485 communication interface | |||||||||
H | HART ® Protocol communication | |||||||||
II | I 2 C Protocol communication | |||||||||
|
Code name | Shape interface | ||||||||
Electrical interface | Mechanical interface | |||||||||
Housman socket ( J1 ) | G¼ | |||||||||
Aviation socket ( J2 ) | G½ | |||||||||
Waterproof connector ( J3 ) | G1 | |||||||||
Liquid level outlet ( J4 ) | M20×1.5 | |||||||||
Others ( J5 ) | others ( Direct label ) | |||||||||
|
Code name | Additional features | ||||||||
M 1 | 4-digit LCD digital display header ( only 4mA ~ 20mADCoutput ) | |||||||||
M 2 | 4-digit LED digital display header ( only 4mA ~ 20mADC output ) | |||||||||
d | Flameproof ExdIICT5 | |||||||||
i |
Intrinsically safe explosion-proof type e
xiaIICT6 |
|||||||||
QT | Other functions | |||||||||
CYB4211 [102] G U 1 V 3 J 1 G½ Complete model specifications |