The compact CPU 1214C has:
| Device versions | ||||
| Option | Supply voltage | Input voltage DI | Output voltage DO | Output current |
|
24 V DC | 24 V DC | 24 V DC | 0.5 A, transistor |
|
24 V DC | 24 V DC |
5 … 30 V DC /
5 … 250 V AC |
2 A;
30 W DC / 200 W AC |
|
85 … 264 V AC | 24 V DC |
5 … 30 V DC /
5 … 250 V AC |
2 A;
30 W DC / 200 W AC |
|
SIMATIC S7-1200, CPU 1214C, compact CPU, DC/DC/relay, onboard I/O: 14 DI 24 V DC; 10 DO relay 2 A; 2 AI 0-10 V DC, power supply: DC 20.4-
28.8 V DC, program/data memory 100 KB |
|
| General information | |
| Product type designation |
CPU 1214C DC/DC/relay
V4.5 |
| Firmware version | |
| Engineering with | |
|
STEP 7 V17 or higher |
| Supply voltage | |
Rated value (DC)
|
Yes 20.4 V 28.8 V Yes |
| permissible range, lower limit (DC) | |
| permissible range, upper limit (DC) | |
| Reverse polarity protection | |
| Load voltage L+ | |
|
24 V
20.4 V 28.8 V |
| Input current | |
| Current consumption (rated value) |
500 mA; CPU only
1 500 mA; CPU with all expansion modules 12 A; at 28.8 V 0.8 A²·s |
| Current consumption, max. | |
| Inrush current, max. | |
| I²t | |
| Output current | |
| for backplane bus (5 V DC), max. | 1 600 mA; Max. 5 V DC for SM and CM |
| Encoder supply | |
| 24 V encoder supply | |
|
L+ minus 4 V DC min. |
| Power loss | |
| Power loss, typ. | 12 W |
| Memory | |
| Work memory | |
|
100 kbyte
No |
| Load memory | |
|
4 Mbyte
with SIMATIC memory card |
| Backup | |
|
Yes Yes
Yes |
| CPU processing times | |
| for bit operations, typ. |
0.08 µs; / instruction
1.7 µs; / instruction 2.3 µs; / instruction |
| for word operations, typ. | |
| for floating point arithmetic, typ. | |
| CPU-blocks | |
| Number of blocks (total) | DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used |
| OB | |
|
Limited only by RAM for code |
| Data areas and their retentivity | |
| Retentive data area (incl. timers, counters, flags), max. | 14 kbyte |
| Flag | |
|
8 kbyte; Size of bit memory address area |
| Local data | |
|
16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB |
| Address area | |
| Process image | |
|
1 kbyte
1 kbyte |
| Hardware configuration | |
| Number of modules per system, max. | 3 comm. modules, 1 signal board, 8 signal modules |
| Time of day | |
| Clock | |
|
Yes
480 h; Typical ±60 s/month at 25 °C |
| Digital inputs | |
Number of digital inputs
|
14; Integrated
6; HSC (High Speed Counting) Yes |
| Source/sink input | |
| Number of simultaneously controllable inputs | |
| all mounting positions | |
| - up to 40 °C, max. | 14 |
| Input voltage | |
|
24 V
5 V DC at 1 mA 15 V DC at 2.5 mA |
| Input delay (for rated value of input voltage) | |
| for standard inputs | |
|
- parameterizable
- at "0" to "1", min. - at "0" to "1", max. |
0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four
0.2 ms 12.8 ms |
| for interrupt inputs | |
| - parameterizable | Yes |
| for technological functions | |
| - parameterizable |
Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3
@ 30 kHz |
| Cable length | |
|
500 m; 50 m for technological functions
300 m; for technological functions: No |
| Digital outputs | |
| Number of digital outputs | 10; Relays |
| Switching capacity of the outputs | |
|
2 A
30 W with DC, 200 W with AC |
| Output delay with resistive load | |
|
10 ms; max. |
|
10 ms; max. |
| Relay outputs | |
|
10
mechanically 10 million, at rated load voltage 100 000 |
| Cable length | |
|
500 m
150 m |
| Analog inputs | |
| Number of analog inputs | 2 |
| Input ranges | |
|
Yes |
| Input ranges (rated values), voltages | |
|
Yes
≥100k ohms |
| Cable length | |
|
100 m; twisted and shielded |
| Analog outputs | |
| Number of analog outputs | 0 |
| Analog value generation for the inputs | |
| Integration and conversion time/resolution per channel | |
|
10 bit Yes
625 µs |
| Encoder | |
| Connectable encoders | |
|
Yes |
| 1. Interface | |
| Interface type | PROFINET |
| Isolated | Yes |
| automatic detection of transmission rate | Yes |
| Autonegotiation | Yes |
| Autocrossing | Yes |
| Interface types | |
|
Yes 1
No |
| Protocols | |
|
Yes |
|
Yes |
|
Yes |
|
Yes; Optionally also encrypted |
|
Yes |
|
No |
| PROFINET IO Controller | |
|
100 Mbit/s |
| Services | |
| - PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
| - Isochronous mode | No |
| - IRT | No |
| - PROFIenergy | No |
| - Prioritized startup | Yes |
| - Number of IO devices with prioritized startup, | 16 |
| max. | |
| - Number of connectable IO Devices, max. | 16 |
| - Number of connectable IO Devices for RT, | 16 |
| max. | |
| - of which in line, max. | 16 |
| - Activation/deactivation of IO Devices | Yes |
| - Number of IO Devices that can be | 8 |
| simultaneously activated/deactivated, max. | |
| Standards, approvals, certificates | |
| CE mark |
Yes
Yes |
| UL approval | |
| cULus | Yes |
| FM approval |
Yes
Yes Yes |
| RCM (formerly C-TICK) | |
| KC approval | |
| Marine approval | Yes |