Low Noise Chilled Water Ceiling Cassette Fan Coil Unit
1.Ceiling cassette fan coil brief introduction
(1)The water cassette fan coils are able to meet the several and different requirements of air conditioning and heating market. Intended for ceiling and false ceiling installation.
(2)Cooling power capacity from 2KW up to 15KW; Heating power capacity from 3.1KW up to 24KW for 2 pipe system.
(3)Versions for 2 pipe and 4 pipe.
(4)Cassette fan coil is widely applied in bureaux, business building, superstore, hotel, hospital, bank, apartment and amusement place, etc.
2. Ceiling cassette fan coil unit main components
(1) Fan
(2) Motor
(3) Cover panel
(4) Heat exchanger
(5)Mastert unit casing
(6)Drained pump
(7) Washable filter
(8) Remote controller

3. Ceiling cassette fan coil features(1) Excellent performance
Air flow capacities from 200 to 1600 CFM, 2-pipe or 4-pipe system combinations, economical, 3-speed fans deliver the right amount of conditioned air for comfort needs at any load.
(2) High reliability
Coils are factory leak tested at 3.3MPa air pressure with coil submerged in water. Base units are CE certified for European standards. Unit casing meets requirements for flame and smoke generation.
(3) Easy maintenance
Removable panels make access to components and connections easy. Cleanable filters available.
Label information adhered to each unit includes model, cooling capacity, electrical information.
(4) Simple installation
Piping, drain and wiring connections are readily accessible. Predrilled mounting holes and slots.
Compact unit casing accommodates installation in reduced ceiling plenum space.
4. Eurostars Fan coil unit series

1 | Ceiling concealed fan coil unit |
2 | High ESP ducted fan coil unit |
3 | Universal concealed fan coil unit |
4 | Floor standing exposed fan coil unit |
5 | Ultra thin exposed fan coil unit |
6 | Ceiling exposed fan coil unit |
7 | Ceiling cassette fan coil unit |
8 | Ceiling exposed & floor standing fan coil unit |
9 | Wall mounted fan coil unit |
5. Ceiling cassette fan coil unit specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.comCassette Fan Coil Unit (4-way 2 pipe system) |
Model EST~ | 200C2 | 300C2 | 400C2 | 500C2 | 600C2 | 800C2 | 1000C2 | 1200C2 | 1400C2 | 1600C2 |
Power supply | 220V-1PH-50/60HZ |
Air flow (m3/h) | H | 360 | 540 | 720 | 900 | 1080 | 1430 | 1780 | 2130 | 2480 | 1830 |
M | 290 | 390 | 525 | 670 | 775 | 1050 | 1290 | 1560 | 1810 | 2050 |
L | 190 | 270 | 350 | 440 | 540 | 720 | 870 | 1060 | 1290 | 1370 |
Static pressure | Pa | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Cooling capacity | TH | H | W | 2000 | 3000 | 3800 | 4900 | 5800 | 7500 | 9800 | 11000 | 12000 | 15000 |
BTU/h | 6826 | 10239 | 12969 | 16724 | 19795 | 25598 | 33447 | 37543 | 40956 | 51195 |
SH | W | 1400 | 2200 | 2850 | 3500 | 4250 | 5500 | 7150 | 8250 | 9100 | 11175 |
BTU/h | 4778 | 7509 | 9727 | 11946 | 14505 | 18772 | 24403 | 28157 | 31058 | 38140 |
TH | M | W | 1700 | 2550 | 3250 | 4150 | 4950 | 6400 | 8350 | 9350 | 10200 | 12450 |
BTU/h | 5802 | 8703 | 11092 | 14164 | 16894 | 21843 | 28499 | 31912 | 34813 | 42492 |
SH | W | 1150 | 1800 | 2350 | 2850 | 3500 | 4550 | 5950 | 6850 | 7650 | 9560 |
BTU/h | 3925 | 6143 | 8021 | 9727 | 11946 | 15529 | 20307 | 23379 | 26109 | 32628 |
TH | L | W | 1400 | 2050 | 2600 | 3400 | 4000 | 5200 | 6750 | 7600 | 8300 | 10300 |
BTU/h | 4778 | 6997 | 8874 | 11604 | 13652 | 17748 | 23038 | 25939 | 28328 | 35154 |
SH | W | 950 | 1400 | 1850 | 2300 | 2800 | 3600 | 4700 | 5450 | 6000 | 8400 |
BTU/h | 3242 | 4778 | 6314 | 7850 | 9556 | 12287 | 16041 | 18601 | 20478 | 28669 |
Heating capacity | H | W | 3100 | 4700 | 5900 | 7600 | 9000 | 11600 | 15200 | 17100 | 18600 | 24000 |
BTU/h | 10580 | 16041 | 20137 | 25939 | 30717 | 39591 | 51878 | 58362 | 63482 | 81912 |
M | W | 2650 | 4000 | 5000 | 6450 | 7650 | 9850 | 12900 | 14550 | 15800 | 19900 |
BTU/h | 9044 | 13652 | 17065 | 22014 | 26109 | 12900 | 44028 | 49659 | 53925 | 67919 |
L | W | 2100 | 3150 | 3950 | 5100 | 6050 | 7750 | 10200 | 11450 | 12450 | 15200 |
BTU/h | 7167 | 10751 | 13481 | 17406 | 20649 | 26451 | 34813 | 39079 | 42492 | 51878 |
Cassette Fan Coil Unit(4-way 4 pipe system) | |
Model EST~ | 200C4 | 300C4 | 400C4 | 500C4 | 600C4 | 800C4 | 1000C4 | 1200C4 | 1400C4 | 1600C4 |
Power supply | 220V-1PH-50/60HZ |
Air flow (m3/h) | H | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | 2720 |
M | 280 | 380 | 515 | 660 | 765 | 1040 | 1280 | 1550 | 1800 | 2040 |
L | 180 | 260 | 340 | 430 | 530 | 710 | 860 | 1050 | 1280 | 1360 |
Sta.pressure | | Pa | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Cooling capacity | TH | H | W | 1950 | 2950 | 3700 | 4800 | 5700 | 7350 | 9600 | 10800 | 11750 | 13200 |
BTU/h | 6655 | 10068 | 12628 | 16382 | 19454 | 25086 | 32765 | 36860 | 40103 | 45052 |
SH | W | 1350 | 2150 | 2800 | 3450 | 4150 | 5400 | 7000 | 8100 | 8900 | 10000 |
BTU/h | 4608 | 7338 | 9556 | 11775 | 14164 | 18430 | 23891 | 27645 | 30376 | 34130 |
TH | M | W | 1650 | 2500 | 3200 | 4050 | 4850 | 6250 | 8200 | 9150 | 10000 | 11000 |
BTU/h | 5631 | 8533 | 10922 | 13823 | 16553 | 21331 | 27987 | 31229 | 34130 | 37543 |
SH | W | 1150 | 1750 | 2300 | 2800 | 3450 | 4450 | 5850 | 6700 | 7500 | 37532 |
BTU/h | 3925 | 5973 | 7850 | 9556 | 11775 | 15188 | 19966 | 22867 | 25598 | 128097 |
TH | L | W | 1350 | 2000 | 2550 | 3350 | 3900 | 5100 | 6600 | 7450 | 8150 | 9100 |
BTU/h | 4608 | 6826 | 8703 | 11434 | 13311 | 17406 | 22526 | 25427 | 27816 | 31058 |
SH | W | 950 | 1350 | 1800 | 2250 | 2750 | 3550 | 4600 | 5350 | 5900 | 6600 |
BTU/h | 3242 | 4608 | 6143 | 7679 | 9386 | 12116 | 15700 | 18260 | 20137 | 22526 |
Heating capacity | H | W | 1950 | 3000 | 3750 | 4850 | 5750 | 7400 | 9700 | 10900 | 11850 | 13500 |
BTU/h | 6655 | 10239 | 12799 | 16553 | 19625 | 25256 | 33106 | 37202 | 40444 | 46076 |
M | W | 1700 | 2550 | 3200 | 4100 | 4850 | 6250 | 8200 | 9250 | 10050 | 11200 |
BTU/h | 5802 | 8703 | 10922 | 13993 | 16553 | 21331 | 27987 | 31570 | 34301 | 38226 |
L | W | 1350 | 2000 | 2500 | 3250 | 3850 | 4950 | 6500 | 7300 | 7950 | 8750 |
BTU/h | 4608 | 6826 | 8533 | 11092 | 13140 | 16894 | 22185 | 24915 | 27133 | 29864 |
Remarks:
(1) Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2) Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature 60°C/50ºC. 6. Ceiling cassette fan coil construction features

7. Our company certificates and fan coil production line
Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.
Every fan coil has strict production process, including assembly, testing, packing.



8. FAQ
Q: Can I have a sample for testing before ordering products?
A: Yes, you can. And you are warmly welcomed to visit our factory before PO.
Q: What is the warranty of products?
A: Warranty: 12~24 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
Q: How to properly install the fan coil unit?
A: We have very detailed user manual and installation instructions, also can be directly telephone or online video guidance.
9. Our service and Customer visit
Considerate after-sales service & product maintenance.You can contact us at any time.
Economical and energy-saving design scheme
Overseas engineer services
Integrated quality and profession R&D team
OEM/ODM available
10. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.

11. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..