| No. | Test item (Test at normal temperature 25±2ºC ) | Criterion | |
| 1 | Communication Interface | SMBus | |
| 2 | Capacity | Designing battery capacity (4S5P) | 30Ah |
| Max capacity (Battery pack) | 290Ah | ||
| Min capacity (Battery pack) | 100mAh | ||
| External capacity Indication | LED,LCD | ||
| Gas gauge algorithm | CEDV | ||
| 3 | Voltage | Charging voltage(4S) | DC :16.8V CC/CV ( 4.2v/Cell) |
| 4 | Balance | Cell-balance window | 100mv |
| Balance Resistance | 100R | ||
| CCC Voltage threshold | 3.27V | ||
| 5 | Supply Current | Normal mode (Firmware running, no flash writes) | 500uA |
| Sleep mode | 100uA | ||
| Shutdown mode | 1uA | ||
| Maximal continuous charging current | 30A(Max) | ||
| Maximal continuous discharging current | 30A(Max) | ||
| 6 | Over-charge Protection (single cell) | Over-charge detection voltage | 4.25±0.05V |
| Over-charge detection delay time | 1S | ||
| Over-charge release voltage | 4.05±0.05V | ||
| 7 | Over-discharge protection (single cell) | Over-discharge detection voltage | 2.50±0.05V |
| Over-discharge detection delay time | 1S | ||
| Over-discharge release voltage | 3.00±0.05V | ||
| 9 | Short protection | Detection condition | Exterior short circuit |
| Short protection Current | 70±20A(Adjusted) | ||
| Discharge short-circuiting detection delay time | 200-800us | ||
| Release condition | Cut load | ||
| 10 | Resistance | Protection circuitry | ≤40mΩ |
| 11 | Temperature protection | Charge temperature (1st Level Safety) | 55 ºC |
|
Charge temperature detection delay time
(1st Level Safety) |
2s | ||
| Charge release temperature (1st Level Safety) | 50 ºC | ||
| Discharge temperature (1st Level Safety) | 60 ºC | ||
|
Discharge temperature detection delay time
(1st Level Safety) |
2s | ||
| Discharge release temperature (1st Level Safety) | 50 ºC | ||
| Charge temperature (2nd Level Safety) | 65 ºC | ||
|
Charge temperature detection delay time
(2st Level Safety) |
0s | ||
| Discharge temperature (2st Level Safety) | 75 ºC | ||
|
Discharge temperature detection delay time
(2st Level Safety) |
0s | ||
| Operating temperature | -40 ~+85ºC | ||
| Functional temperature | -40 ~+110ºC | ||
| Storage temperature range | -65 ~+150ºC | ||
| Dimension | L100*W40*T5mm | ||
| B+:Battery+ |
|
||
| B-:Battery- | |||
| SD:SMBus data line | |||
| SC:SMBus clock line | |||
| P+:Charge+/discharge+ | |||
| P-:Charge-/discharge- | |||