Construction Characteristics:
High physically foaming insulation, copper tape formed, welded and corrugated to manufacture the outer conductor.
Advantages:
Low attenuation, low standing wave, high shielding, damp-proof gas free maintenance, flexible, high anti tensile strength.
Application Range:
Broadcast and television, microwave telecommunication, aerospace, vessel or other circumstance where RF cable is needed.
Inner Conductor: Smooth Copper Tube/ Copper Coating Aluminum/ Helix Copper Tube
Dielectric : Physical Foaming Polyethelene(PE)
Outer Conductor: Corrugated Copper Tube/ Annularity Copper Tube/ Helix Copper Tube
Jacket : Black PE or Low Smoke Halogen-free Fire-retardant
| Material | Diamenter (mm) | |
| 1. Inner Conductor | Smooth Copper Tube | 9.0 |
| 2. Dielectric | Physical Foam Polyethylene | 22.5 |
| 3. Outer Conductor | Corrugated Copper Tube | 24.9 |
| 4. Jacket | Black PE | 27.7 |
| Electrical Characteristics | ||
| Capacitance (pF/M) | 76 | |
| Impedance (Ohm) | 50 | |
| Velocity of Propagation (%) | 88 | |
| Peak Power Rating (KW) | 91 | |
| RF Peak Voltage (KV) | 3.0 | |
| Insulation Resistance (MΩ.km) | >5000 | |
| Cut-off Frequency (GHz) | 5.2 | |
| Insulation Voltage (KV) | 10 | |
| Inner Conductor DC Resistance (Ω/km) | 1.00 | |
| Outer Conductor DC Resistance (Ω/km) | 1.20 | |
| Jacket Spark (KV) | 8.0 | |
| Shielding Effectiveness (dB) | >120 | |
| VSWR≤(Return loss≥dB) | ||
| 0.005-3GHz | 1.15 (23) | |
| 0.8-1.0GHz | 1.10 (26) | |
| 1.7-2.0GHz | 1.10 (26) | |
| 2.0-2.4GHz | 1.10 (26) | |
| Mechanical and Environmental Characteristics | ||
| Min. Single Bending Radius (mm) | 90 | |
| Min. Repeated Bending Radius (mm) | 250 | |
| No. of Bends | 15 | |
| Mobile Apply (mm) | 500 | |
| Bending Moment (N.m) | 16.3 | |
| Tensile Strength (kg) | 147 | |
| Storage Temp (ºC) | -55 to +85 | |
| Installation Temp (ºC) | -40 to +60 | |
| Operating Temp (ºC) | -55 to +85 | |
| Attenuation (VSWR1.0, cable temp. 20 ºC ) & Average Power (VSWR 1.0, ambient temp. 40ºC) | ||
| Frequency (MHz) | Attenuation (dB/100m) | Average Power (KW) |
| 100 | 1.17 | 8.62 |
| 200 | 1.69 | 5.99 |
| 450 | 2.60 | 3.88 |
| 800 | 3.56 | 2.83 |
| 900 | 3.80 | 2.65 |
| 1000 | 4.03 | 2.50 |
| 1500 | 5.08 | 1.99 |
| 1800 | 5.61 | 1.79 |
| 2000 | 6.05 | 1.68 |
| 2200 | 6.40 | 1.59 |
| 2400 | 6.75 | 1.54 |
| 2500 | 6.90 | 1.50 |
| 3000 | 7.60 | 1.33 |