Detects direct leakage currents up to 6 mA DC to avoid failure of household residual current device type A.
| Electrical/Reliability Characteristics | |
| Working Temperature | 40ºC~105ºC |
| Storage Temparature | 40ºC~105ºC |
| Supply Voltage(VDD) |
4.85~5.15 VDC
recommend 49*51 VDC |
| Static Power Consumption | 110mW |
|
Clearance
(Primary-Primary/Secondary) |
≥6.5mm
≥10mm |
|
Creepage
Primary-Primary/Secondary) |
≥8mm
≥10mm |
| Voltage Input, low level | 0~0.6VDC |
| Voltage Input, high level | 4.2~5VDC |
| FIT |
25ºC= 48.755
80ºC = 213.13 |
| Designed Life | ≥20 years |
| Working Altitude | ≤4000m |
| Trip-Current (residual current related characteristics. | |||||
| Wav. | Freq. | Min. | Typ | Max. | Unit |
| AC | 50Hz | 20.0 | 23.0 | 26.0 | mA |
| A0° | 50Hz | 11.0 | 15.0 | 30.0 | mA |
| A90° | 50Hz | 10.0 | 20.0 | 30.0 | mA |
| A135° | 50Hz | 10.0 | 24.0 | 35.0 | mA |
| 2PDC | 50Hz | 3.5 | 5.0 | 7.0 | mA |
| 3PDC | 50Hz | 3.1 | 4.6 | 6.2 | mA |
| S-DC | - | 3.0 | 4.6 | 6.0 | mA |
| Trip-Time (residual current related characteristics | ||||
| Wav. | Freq. | Current | TYP. | Unit |
| AC | 50Hz | 30mA | 25 | ms |
| AC | 50Hz | 60mA | 16 | ms |
| AC | 50Hz | 150mA | 15 | ms |
| AC | 50Hz | 5A~100A | 8.5 | ms |
| A0° | 50Hz | 42mA | 25 | ms |
| A0° | 50Hz | 84mA | 18 | ms |
| A0° | 50Hz | 210mA | 10 | ms |
| A0° | 50Hz | 42mA+6mADC | 18 | ms |
| A0° | 50Hz | 84mA+6mADC | 15 | ms |
| A0° | 50Hz | 210mA+6mADC | 15 | ms |
| S-DC | 6mA | 48 | ms | |
| S-DC | 60mA | 16 | ms | |
| S-DC | 300mA | 8.5 | ms | |
| 2PDC/3PDC | 50Hz | 60mA | 20 | ms |
| 2PDC/3PDC | 50Hz | 120mA | 25 | ms |
| 2PDC/3PDC | 50Hz | 300mA | 12 | ms |
| 2PDC/3PDC | 50Hz | 5~50A | 12 | ms |