Analog Output 6mA DC Fluxgate Leakage Current Sensor for Ground Fault Detection

Model NO.
HGLC-AC/DC Series
Material
Plastic
Accuracy Grade
0.5G
Application
Leakage Current Sensor
IP Rating
IP55
Certification
RoHS
Customized
Customized
Bandwidth
AC 50Hz
Withstand Resistance
Voltage Output-5mA Current Output-6V
Temperature Drift
100ppm/Deg.C
Input Power Supply Voltage Range
DC 12V, DC 15V
Storage Temperature
-25-85 Deg.C
Keywords
DC Residual Leakage Current Sensor
Operating Ambient Temp. Range
-25-80 Deg.C
Response Time
300ms
Rated Output
DC1V, DC2V, DC4V, DC5V, DC 0-20mA, DC 4-20mA
Primary Current
5mA...20mA...50mA...100mA...500mA...800mA...1000mA
Offset Voltage
20mv
Insulation Withstand Voltage
3kv/50Hz,2mA,1min
Accuracy
1%
Linearity
0.5%
Mounting
Screw Fastening Flat Mounting
Transport Package
1kg
Specification
20*15*15cm
Trademark
Siko Instruments
Origin
China
HS Code
9030339000
Production Capacity
999 Units / Weeks
Package Size
25.00cm * 15.00cm * 15.00cm
Package Gross Weight
1.000kg
Reference Price
$ 33.30 - 40.50

Product Description

Analog Output 6mA DC Fluxgate Leakage Current Sensor For Ground Fault Detection

Model: HGLC-SF-1
Window Diameter: Ø25mm 
Primary Nominal Current: DC 5mA-1000mA

Working Principle: HGLC-SF-1 DC Leakage Current Sensor using the principle of magnetic modulation.
Product Use: Closed loop for isolated measurement of DC milliampere small current. 
Application: Widely used in emerging industries, and field such as electric power, industrial automation, solar photovoltaic...leakage monitoring system etc 

Features:  
* The isolation voltage between primary and secondary is greater than 3000VAC.
* Temperature compensation circuit control, zero drift and accurate measurement.
* Perforated input, unplugging terminals and screw fastening flat mounting.
* Overall size(mm): 70(L)*29(W)*60(H)mm; Aperture: 25mm
* Potting glue has elastic characteristics. Good mechanical properties such as corrosion resistance, aging resistance, and heat resistance.

 
Product Description

Analog Output 6mA DC Fluxgate Leakage Current Sensor for Ground Fault Detection Analog Output 6mA DC Fluxgate Leakage Current Sensor for Ground Fault Detection

Features
01.  4-Bits LED Digital Display.
02.   Switching Points Can Be Set Arbitrarily On Site Between Zero And Full Point .
03.   Pressure Measurement For Gas And Liquid.
04.  PNP Switch Point Setting And Time Delay Setting For Action.
05.  PNP Switch Output And Analog 4-20mA Output Optional.
06.  4-20mA, 0-10V, RS 485 Outputs Available.
07.  2 Switch Output (NPN/PNP) With Load Capacity 1.2A.
08.  M12 Standard Electrial Connection.
09.  Button Adjustment And On-site Setting of Various Parameters Easy To Operate.

Analog Output 6mA DC Fluxgate Leakage Current Sensor for Ground Fault Detection Analog Output 6mA DC Fluxgate Leakage Current Sensor for Ground Fault Detection
Product Parameters

Analog Output 6mA DC Fluxgate Leakage Current Sensor for Ground Fault Detection

Selection Table

Analog Output 6mA DC Fluxgate Leakage Current Sensor for Ground Fault Detection

Outline Dimension

Analog Output 6mA DC Fluxgate Leakage Current Sensor for Ground Fault Detection

Electrical Connection

Analog Output 6mA DC Fluxgate Leakage Current Sensor for Ground Fault Detection

Company Profile

Analog Output 6mA DC Fluxgate Leakage Current Sensor for Ground Fault Detection Analog Output 6mA DC Fluxgate Leakage Current Sensor for Ground Fault Detection

 

PNEUTEC.IT, 2023