IEC62955 6mA DC Leakage Protection RCD Sensor Residual Current Monitor with Uart Modbus

Model NO.
MD0630T01A
Customized
Customized
Certificate
CE-EMC/TUV(IEC 629255)
Output
Digital Signal
Usage
EV Charger, New Energy, Solar PV System
Theory
Current Sensor
Installation
Pin/PCB Type
Accuracy
DC 0.2mA, AC 0.3mA
3 Ways Output
DC Alarm, AC Alarm, AC/DC Alarm
Current
DC Current 2~15mA, AC Current 3~100mA
Transport Package
Cartons
Specification
TBA
Trademark
IVY
Origin
Zhejiang, China
HS Code
8536411000
Production Capacity
5, 000, 000.00/ Year
Reference Price
$ 16.88 - 23.63

Product Description

IEC62955 6mA DC Leakage Protection RCD Sensor Residual Current Monitor with Uart Modbus IEC62955 6mA DC Leakage Protection RCD Sensor Residual Current Monitor with Uart Modbus IEC62955 6mA DC Leakage Protection RCD Sensor Residual Current Monitor with Uart Modbus IEC62955 6mA DC Leakage Protection RCD Sensor Residual Current Monitor with Uart Modbus
Voltage 12V±20%
Current DC current 2~15mA, AC current 3 ~100mA
Accuracy DC ±0.2mA, AC±0.3mA  @  25ºC
3 Way s  Output DC alarm, AC alarm, AC/DC alarm
Operation Temperature Range -25 ~ + 80 ºC
Installation Pin   Type
Plastic   Casing SIP encapsulation
IEC62955 6mA DC Leakage Protection RCD Sensor Residual Current Monitor with Uart Modbus IEC62955 6mA DC Leakage Protection RCD Sensor Residual Current Monitor with Uart Modbus IEC62955 6mA DC Leakage Protection RCD Sensor Residual Current Monitor with Uart Modbus IEC62955 6mA DC Leakage Protection RCD Sensor Residual Current Monitor with Uart Modbus          
  Cautions of Smart Sensor:
1.Current value- Please specify your measurement range as per your application, for example if you are going to
use it for detecting and sensing mA level or high  current range such as 500A/600A shall be first factor.
2.AC,DC,or both AC&DC shall be the second factor. Now current sensor on the market usually are AC or DC type.
But if you need both AC& DC you may need to use IVY brand- AC DC leakage sensor.
3.Parameters-Please confirm what kind of parameters shall be measured or detected. For example our smart sensor
with shunt can readout current, voltage,kWh, kVar, Cos
φ,  Hz, THF, current cycle, starting waveform.
5.Installation Method, after making above decision you may also need to confirm the output terminal type, for example we have
shunt / terminal / pillar / pins/ cable etc.
6.
As there are many models of smart electrical sensor, plz refer to the detailed specification and use it as per the instruction.

 