Hybrid storage solar system
Datasheet | MIN 3000TL-XH-US | MIN 3800TL-XH-US | MIN 5000TL-XH-US | MIN 6000TL-XH-US | MIN 7600TL-XH-US |
Input Data(PV) | |||||
Max. Recommended PV Power(STC) | 6000w | 7600w | 10000w | 12000w | 15200w |
DC/AC Ratio | 2 | ||||
Max. DC System Voltage | 600v | ||||
Startup Voltage | 80v | ||||
Full load voltage range | 130-500v | 160-500v | 210-500v | 170-500v | 210-500v |
Nominal Voltage | 360v | ||||
Operating Voltage Range | 50~550V/LG Battery:50~450V | ||||
No. of MPPT | 2 | 2 | 2 | 2 | 2 |
No. of PV Strings per MPPT | 2/2 | 2/2 | 2/2 | 2/2 | 2/2 |
Max. Input Current per MPPT | 13.5A | ||||
Max. Short-circuit Current per MPPT | 16.9A | ||||
Input/Output Data (Battery) | |||||
I/O Voltage Range | ARO Battery :360V~550V/LG Battery:350V~450V | ||||
Nominal DC Voltage | 400V | ||||
I/O DC Current | 9A/9A | 11.5A/11.5A | 15A/15A | 18A/18A | 23A/23A |
I/O DC Powe | 3200W | 4000W | 5200W | 6200W | 7800W |
Battery Technology | LFP / NMC | ||||
Battery Capacity per Module | 9.9kWh / 10kWh,16kWh | ||||
Scalability | Up to 4 / Up to 2 in parallel | ||||
Compatible Batterys | Growatt ARO HV battery / LG Prime (Gen3) battery | ||||
Output Data (AC) | |||||
AC Nominal Power@240V AC | 3000W | 3800W | 5000W | 6000W | 7600W |
AC Nominal Power@208V AC | 2600W | 3290W | 4330W | 5200W | 6580W |
Max. AC Apparent Power | 3000VA | 3800VA | 5000VA | 6000VA | 7600VA |
Nominal AC Voltage | 208V/240V | ||||
AC Voltage Range @208V AC @240V AC | 183V~229V/211V~264V | ||||
AC Grid Frequency | 50/60Hz | ||||
AC Grid Frequency Range | 45~65Hz | ||||
Max. Output Current | 12.5A | 16A | 21A | 25A | 32A |
Power Factor(@Nominal Power) | >0.99 | ||||
Adjustable Power Factor | 0.8 Leading~0.8 Lagging | ||||
THDi | <3% | ||||
AC Grid Connection Type | L1/L2/N/PE | ||||
Output Data (Backup) | |||||
AC Nominal Power | 3000W | 3800W | 5000W | 6000W | 7600W |
Max. AC Power Output | 3600VA | 4560VA | 6000VA | 7200VA | 9120VA |
Nominal AC Voltage | 240V | ||||
Max. Output Current | 15A | 19A | 25A | 30A | 38A |
THD | 5% | ||||
AC Port-V2 inverter | 2AC Ports, 1 for ON Grid, 1 for Backup(EPS ) compatible with ATS-US for Partial Home Backup | ||||
AC Port-V3 Inverter | 1AC Port for 1 ON Grid compatible with SYN200-US for Whole Home Backup | ||||
Efficiency | |||||
Max. Efficiency | 98.00% | 98.00% | 98.20% | 98.40% | 98.40% |
CEC Efficiency@240V AC | 97.00% | 97.00% | 97.50% | 97.00% | 97.50% |
CEC Efficiency@208V AC | 96.50% | 97.00% | 97.50% | 97.00% | 97.00% |
Protection Devices | |||||
DC Reverse-polarity Protection | Yes | ||||
DC Switch | Yes | ||||
DC Surge Protection | Type II | ||||
Insulation Resistance Monitoring | Yes | ||||
AC Surge Protection | Type III | ||||
AC Short-circuitS Protection | Yes | ||||
Ground Fault Monitoring | Yes | ||||
Grid Monitoring | Yes | ||||
Anti-islanding Protection | Yes | ||||
Residual-current Monitoring Unit | Yes | ||||
AFCI Protection | Yes |