Singi Sg65le-63 4p+N Factory Supply Earth Leakage Breaker Overcurrent Protection RCBO Price

Model NO.
SG65LE-63
Standard
IEC60898
Pole
4
Protection
Overload and Short Circuit
Rated Current
6AMP
Transport Package
Circuit Breaker MCB Standard Exporting Carton
Trademark
SINGI
Origin
Zhejiang, China
Production Capacity
50000 Piece/Pieces Per Day
Reference Price
$ 3.60 - 16.20

Product Description

Product Description

Singi Sg65le-63 4p+N Factory Supply Earth Leakage Breaker Overcurrent Protection RCBO Price Singi Sg65le-63 4p+N Factory Supply Earth Leakage Breaker Overcurrent Protection RCBO Price Singi Sg65le-63 4p+N Factory Supply Earth Leakage Breaker Overcurrent Protection RCBO Price

Key Parameters:

  • CE/CB/ISO9001/CCC certificates;
  • Rated voltage:230/400VAC;
  • frequency50/60Hz;
  • Rated current:1,3,6,10,16,20,25,32,40,50,63A;
  • 1/2/3/4poles optional;
  • Mechniacal life:20,000times;
  • Flame-redardant:PA66 nylon material;
  • Protection degree:IP20;
  • With over load/short circuit protection;
  • Standard:IEC60898;
  • Enduring tem.30°C
  • Breaking Capacity:4/6KA;
  • Lighting/Motor protection optional

Application:

SG65LE RCBO is applied in the power system of AC 50Hz, single phase 230V, three phases 400V. When somebody gets and electric shock or the residual current exceeds the default value, the RCBO can cut off the powerautomatically to protect the personal safety and prevent the equipmentfrom the fault resulted from the residual current. It also can protect the circuit aqainst overload and short circuit or can be used for the unfrequent switch of the circuit under normal condition. And extra protection functions like over voltage, under voltage can be added according to customers' request.


It conforms to the standard IEC1009-1. GB16917.1.

 

Structure

SG65LE-63 series RCBO is composed of SG65-63 high breaking MCB and residual current release. This RCBO is current operating electronic RCBO, the main parts including zero sequence current transformer, electronic panel, current leakage release and the circuit breaker with protection functions of overload, short circuit.

 

Technical Parameters

 

Shell level rated current(A) voltage(V) Pole Rated current In(A) Rated short circuit breaking capacity Rated residual current breaking current(mA) Rated residual current no breaking current(mA) Trip time
Breaking capacity Ics(A) COSφ
63 230 1P+N

60,10,

16,20,

25,32,

40,50,

63

6000 0.75 10 5 ≤0.1S
230 2P 30 15
400 3P 50 25
400 3P+N 75 37.5
400 4P 100 50

 

Singi Sg65le-63 4p+N Factory Supply Earth Leakage Breaker Overcurrent Protection RCBO Price Singi Sg65le-63 4p+N Factory Supply Earth Leakage Breaker Overcurrent Protection RCBO Price Singi Sg65le-63 4p+N Factory Supply Earth Leakage Breaker Overcurrent Protection RCBO Price Singi Sg65le-63 4p+N Factory Supply Earth Leakage Breaker Overcurrent Protection RCBO Price Singi Sg65le-63 4p+N Factory Supply Earth Leakage Breaker Overcurrent Protection RCBO Price Singi Sg65le-63 4p+N Factory Supply Earth Leakage Breaker Overcurrent Protection RCBO Price

Company Information

 

Singi Sg65le-63 4p+N Factory Supply Earth Leakage Breaker Overcurrent Protection RCBO Price Singi Sg65le-63 4p+N Factory Supply Earth Leakage Breaker Overcurrent Protection RCBO Price  

 

 

PNEUTEC.IT, 2023