Efficient
Higher Revenue |
*Max. Efficiency 97.5%
*Max. PVInput Voltage 550V *150% Peak Output Power *2 MPP Trackers, 150% DC Input Oversizing *Max. PVInput Current 16A, Compatible with High Power Modules |
Intelligent
Simple O&M
|
*IP66 Protection Degree: support outdoor installation
*Smart I-V Curve Diagnosis Function: locate PV string faults accurately and automatically detect faults
*DC & AC Type II SPD: prevent lightning damage
*Battery Reverse Connection Protection
|
Flexible
Abundant Confifiguration
|
*Plug & Play, EPS Switching Under 10ms
*Compatible with Lead-acid and Lithium Batteries
*Max. 6units Inverters Parallel
*AFCI Function (Optional): when an arc-fault is detected the inverter immediately stops operation
|
Input(PV) | |||||
Max. PV Input Power | 5.4kw | 6kW | 6.9kw | 7.5kw | 9kW |
Max. PV Input Voltage | 550V | ||||
Start-up Voltage | 100V | ||||
Rated Voltage | 240V | 270V | 300V | 330v | 360V |
MPPT Voltage Range | 100V~550V | ||||
Number of Input Current | 2 | ||||
Max. PV Input Current | 16A | ||||
Output(AC) | |||||
Rated Output Power | 3.68kVA | 4kVA | 4.6kVA | 5kVA | 6kVA |
Max. Output Power | 3.68kVA | 4.4kVA | 4.6kVA | 5.5kVA | 6.6kVA |
Max. Output Current | 16A | 20A | 20.9A | 22.7A | 30A |
Rated Voltage | 230V | ||||
Rated Frequency | 50Hz/60Hz | ||||
THDi(@Rated Power) | <3% | ||||
Power Factor | 0.8 leading~0.8lagging | ||||
Output(EPS) | |||||
Max. Output Power | 3.68kVA | 4kVA | 4.6kVA | 5kVA | 6kVA |
Max. Output Current | 16A | 20A | 20.9A | 22.7A | 30A |
Peak Output Power, Time | 5.5kW,10s | 6kW,10s | 6.9kW,10s | 7.5kW,10s | 7.5kW,10s |
Rated Voltage,Frequency | 230V,50Hz | ||||
THDv(@Rated Power) | <3% | ||||
Switch Time | < 10ms | ||||
Battery | |||||
Battery Type | Lithium, Lead-acid | ||||
Battery Voltage Range | 40V~60V | ||||
Max. Charge / Discharge Current | 100A | ||||
Communication | CAN | ||||
Efficiency | |||||
Max. Efficiency | 97.50% | ||||
EU Efficiency | 97.20% | ||||
Battery Charge/Discharge Efficiency | 95% | ||||
Protection | |||||
DC Reverse Polarity Protection /Insulation
Resistance Monitoring/ Ground Fault Monitoring |
Yes | ||||
Over Current/Over Voltage Protection | Yes | ||||
Battery Soft Start Protection | Yes | ||||
AFCI Protection | Optional | ||||
Surge Protection | Type II | ||||
Communication | |||||
Display | LCD | ||||
Communication | RS485/CAN /WIFI/4G /LAN /Bluetooth | ||||
General Data | |||||
Dimension (W*H*D) | 490×395×200 mm | ||||
Weight | 15kg | ||||
Operating Temperature Range | -30ºC~+60ºC | ||||
Cooling Method | Natural | ||||
Protection Degree | IP66 | ||||
Max. Operating Altitude | 4000m | ||||
Noise | ≤25dB | ||||
Relative Humidity | 0~100% | ||||
Self-consumption | <10W | ||||
Topology | High Frequency Insolation (For battery) |