Num | Item | Technical requirement | Remark |
1 | Input voltage | 380V±10% , 50Hz±2Hz |
Three phase and four
wire |
2 |
Microwave output
power |
≥6kW | Continuous wave |
3 |
Microwave output
frequency |
2450MHz±15MHz | |
4 |
Microwave conversion
efficiency |
≥65% |
|
5 | MW-Power adjust | 10%~100% continuous adjustment | |
6 |
Flange joint |
BJ22/BJ26 |
|
7 | Control mode | Local control/communication | |
8 |
Protection |
Filament over current and under current
;
Anode overpressure and overcurrent
;
Magnetic field overcurrent
;
Ignition ; Magnetron over-temperature ; Water protection ; reflection protection |
|
9 |
Volume |
HF-Power supply
:
482mm*177mm*556mm
M-W Head : 200mm*250mm*300mm |
W*H*D |
10 |
Usage environment |
Work temperature
:
-10~40
ºC
Storage temperature
:
-20~50
ºC
Humidity
:
95%no condensation
Altitude :< 3000m |
< 0 ºC antifreeze required |
11 |
Cooling mode |
Water |
External supply of equipment
,
Flow≥2.5L/min |
Num | Code | Form | Type | Pin | Definition | Characteristic |
1 |
XS1 |
Terminal block |
TD40-01-C |
1 | A |
Power supply |
2 | B | |||||
3 | C | |||||
4 | N | |||||
2 |
XS2 |
Terminal block |
2EDGRKP-5.08/WC-8P |
1 | VCC | +24V |
2 | TEMP |
Temperature
switch signal |
||||
3 | FLOW |
Flow switch
signal |
||||
4 | GND | 24VGND | ||||
5 | / | / | ||||
6 | A1 |
PC communication |
||||
7 | B1 | |||||
8 | RGND | |||||
3 |
XS3 |
Terminal block |
2EDGRKP-5.08/WC-4P |
1 | VCC | +24V |
2 | GND | 24VGND | ||||
3 | A2 | Function expansion port | ||||
4 | B2 | |||||
4 |
XS4 |
Terminal block |
2EDGRKP-5.08/WC-2P |
1 | C+ |
Magnetic field
output+ |
2 | C- |
Magnetic field
output- |
||||
5 | X1 | Terminal | JS333 ( M6 black ) | / | HGND | HV-GND |
6 | X2 | Stud | M6 ( butterfly shape ) | / | PE | Safety GND |
7 |
HV |
HV- Conductor |
White AEG-15kV-2.5mm² |
/ | FA | Filament output |
/ | A |
Anode
HV-Output |
||||
8 | IN |
Quick screw joint |
G1/4-Ø12*8 | / | / | Water inlet |
9 | OUT | G1/4 Ø12*8 | / | / | Water outlet |
Num | Code | Form | Type | Pin | Definition | Characteristic |
1 |
HV |
High pressure tightness plug |
BL-HV15kV |
/ |
FA |
Filament output |
BL-HV15kV |
/ |
A |
Anode
HV-Output |
|||
2 | X1 | Terminal | JS333 ( M6 black ) | / | HGND | HV-GND |
3 | X2 | Stud | M6 ( butterfly shape ) | / | PE | Safety GND |
4 |
XS1 |
Terminal block |
2EDGRKP-5.08/WC-6P |
1 | VCC | +24V |
2 |
TEMP |
Temperature
switch signal |
||||
3 |
FLOW |
Flow switch
signal |
||||
4 | GND | 24VGND | ||||
5 | / | / | ||||
6 | / | / | ||||
5 | IN |
Quick screw joint |
G1/4-Ø12*8 | / | / | Water inlet |
6 | OUT | G1/4 Ø12*8 | / | / | Water outlet | |
7 |
/ |
Flange |
BJ26 |
/ |
/ |
MW-Output |