Model
|
|
S-1200-12
|
S-1200-15
|
S-1200-24
|
S-1200-48
|
|
Output
|
DC output Voltage
|
12V
|
15V
|
24V
|
48V
|
|
Voltage tolerance
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
|
Rated Current
|
100A
|
80A
|
50A
|
25A
|
|
Related Power
|
1200w
|
1200w
|
1200w
|
1200w
|
|
Wave&Noise
|
240mVp-p
|
240mVp-p
|
240mVp-p
|
300mVp-p
|
|
Adjustable range for DC Voltage
|
±10%
|
±10%
|
±10%
|
±10%
|
|
Set up,rise,hold up time
|
200ms 100ms 30ms
|
|
Input
|
Voltage Range
|
170-264VAC 47-63HZ
|
|
Input Current
|
7A/230VAC
|
|
Efficiency
|
83%
|
84%
|
85%
|
87%
|
|
AC inrush current
|
Cold start current 50A /230VAC
|
|
Leakage current
|
<3.5mA/240VAC
|
|
Protection
|
Overload
|
Related output power 105-150% start overload protection
|
|
Protection type: cutoff output, recovery after restart power
|
|
Over voltage
|
13.8V-16.2V
|
17.2V-20.2V
|
27.6V-32.4V
|
55V-64.8V
|
|
Hiccup mode,recovers automatically after fault condition
|
|
Environment
|
Working temp humidity
|
-10~+60°C 20%~90%RH
|
|
Stor temp, humidity
|
-20~+85°C 20%~90%RH Non-condensing
|
|
Safety
|
Withstand voltage
|
I/P-O/P:1.5KVAC 1min
|
|
I/P-FG:1.5KVAC 1min
|
|
O/P-FG:0.5KVAC 1min
|
|
Standard
|
Safety standard
|
Fit UL1012
|
|
Refer
|
Design refer to GB4943,UL60950,EN60950
|
|
EMC standard
|
Design refer to GB9254,EN55022 Class A
|
|
Size
|
size
|
L291*W132*H68mm
|
|
Package
|