| Model | SPS30-48 /MR4815 | SPS60-48 /CR4830 | SPS90-48 /CR4830 | SPS120-48 /CR4830 | SPS210-48 /CR4830 | SPS200-48 (SR4850 ) | WPS30-48 /MR4815 | WPS60-48 /MR4815 | |
| Output Current | 30A | 60A | 90A | 120A | 210A | 200A | 30A | 60A | |
| Rated Output Power | 1740W | 3600W | 5400W | 7200W | 12600W | 11600W | 1740W | 3600W | |
| Rated Output Voltage | 53.5Vdc (42-58 Vdc) | ||||||||
| AC Input | |||||||||
| Voltage Range | 176~300Vac, 1phase/3wire (@ full load) | ||||||||
| Frequency | 45Hz ~65Hz | ||||||||
| Power Factor | ≥0.99 | ||||||||
| Efficiency | ≥91% | ≥92% | |||||||
| AC Input | 1pc*30A/1P | 1pc*30A/3P | 1pc*50A/2P | 1pc*63A/2P | 1pc*100A/2P | 1pc*100A/2P | 1pc*30A/2P | 1pc*30A/2P, | |
| Lightening protection | NA | ClassC SPD | ClassC SPD | ClassC SPD | ClassC SPD | ClassC SPD | ClassC SPD | ||
| DC Output | |||||||||
| Voltage Range | 42~58 Vdc | ||||||||
| Current Sharing | ±5% | ||||||||
| Load Regulation | ≤0.5% | ||||||||
| Voltage Regulation | ≤0.1% | ||||||||
| Operating Environment | |||||||||
| Temperature | (-20 to 50C) (Rectifier Temp Range: -45C to 75C) | ||||||||
| Relative Humidity | 5%`95% RH, No Condensation | ||||||||
| Configuration | |||||||||
| Rectifier Module | 2*MR4815 | 2*CR4830 | 3*CR4830 | 4*CR4830 | 7*CR4830 | 4*SR4850 | 2*MR4815 | 4*MR4815 | |
| Controller | 1*CAS-03 | 1*CAS-03 | 1*CAS-03 | 1*CAS-03 | 1*CAS-03 | 1*CAS-03 | 1*CAS-03 | 1*CAS-03 | |
| DC Distribution | 1pc*30A | 1pc*60A | 4pcs*32A/1P 4pcs*16A/1P | 2pcs*63A/1P 4pcs*32A/1P 4pcs*16A/1P |
1st LVD: 2pcs*63A /1P 4pcs*32A/1P
2nd LVD: 4pcs*16A /1P DC SPD (40kA) |
1st LVD: 1pc* 63A /1P 5pcs*32A/1P
2nd LVD: 2pcs*16A /1P 2pcs*32A/1P |
5pcs*16A /1P 1pcs*32A/1P | 5pcs*16A /1P 1pcs*32A/1P | |
| Battery Input /&Breaker | 1pc*30A | 1pc*60A |
2pcs*63A/1P
(or 1pc*100A/1P) |
2pcs*100A/1P | 2pcs*100A/1P | 2pcs*100A/1P | 1pcs*32A/2P | 1pcs*32A/2P | |
| Alarm Relay | 4pcs | 4pcs | 4pcs | 4pcs | 4pcs | 4pcs | 4pcs | 4pcs | |
| Others | |||||||||
| Standard | UL60950/EN60950, EN55022, RoHS | ||||||||
| Communication | LAN/RS232 /RS485 | ||||||||
| Dimension (mm) | 482*290*44 (Subrack) | 482*290*44 (Subrack) | 482*290*132 (Subrack) | 482*300*176 (Subrack) | 482*300*220 (Subrack) | 482*300*264 (Subrack) | 650*550*300 (wall-mount) IP45 | 650*550*320 (wall-mount) IP45 | |
| Optional | 2nd LVD, DC Lightning Protection at DC output | 2nd LVD, DC Lightning Protection | 2nd LVD, DC Lightning Protection | 2nd LVD, DC Lightning Protection | 2nd LVD, Teperature Compensation Cable, Lead-acid Battery 40Ah, Lithium Iron 40Ah | ||||