| Product Name | Model | Quantity | Remark |
| Cable Fault Tester | EPDL-A | 1 |
Rough measurement of main insulation.
12.1-inch industrial control integrated machine, touch operation |
| Cable Fault Locator | EPDL-D | 1 | LCD display, sound and magnetic synchronization |
| HV Pulse Generator | EPDL-H | 1 | 8kV/64μF, 16kV/16μF, 32kV/4μF three-speed cart type, power 2048J |
| Pulse amplitude: | 100Vpp |
| Pulse width: | 0.1uS and 2uS |
| Measuring distance: | Smax: 60km |
| Smin: 15m | |
| Measurement error: | absolute error of rough measurement: ±10m |
| Relative error of rough measurement: | ±1% |
| Temperature resolution | 0.1 ºC |
| Acousto-magnetic synchronization pin-pointing Cable Fault Locator function: | |
| Sound channel: | Maximum signal gain: >=80dB |
|
Fixed-point accuracy: 0.1m |
|
| Magnetic field channel: | Max. signal gain: >80db |
| Battery: | Built-in lithium-ion battery pack, nominal voltage 7.4V, capacity 3400mAH |
| Use time: | Continuous use time > 7 hours |
| Charger: | Input AC220V±10%, 50Hz. Nominal output 8.4V, 1A |
| Charging time: | <6 hours |
| Display mode: | Transflective 320×240 monochrome liquid crystal |
| Volume: | Host 200mm×195mm×120mm |
| Weight: | Host 2.0kg |
| Sensor 2.5kg | |
| Use conditions: | Temperature:-10 ºC -40 ºC |
| Humidity 5-90%RH | |
| Altitude <4500m | |
| Impact high voltage: | 0 ~ 8/16/32kV three gears optional |
| High voltage divider: | voltage accuracy level 1.5 |
| Built-in capacitance: | 4μF/32kV, 16μF/16kV, 64μF/8kV |
| Discharge power: | all 2048J |
| Impact time: | automatic impact about 4 seconds, manual impact arbitrary control time |
| Impact power: | 2KVA |
| Volume: | 534L×444W×805H |
| Weight: | not more than 75KG |
| Power supply: | AC 220V±10% 50Hz±2Hz |
| Ambient temperature: | -20 ~ +50 ºC |