3p3l/ 3p4l Power Grid Structure 400V 30kvar Static Var Generator Svg

Application Range
Power Plants
Shell Material
Steel Plate
Shell Protection Grade
IP30
Trademark
VSG
Origin
China
Reference Price
$ 9,000.00 - 18,000.00

Product Description


APF
Most of the widely used loads are nonlinear loads, such as rectifiers, frequency converter, UPS, elevator, air conditioner, energy-saving lamp, copier, household appliances, etc. These nonlinear loads will produce a large number of harmonic currents and inject them into the power grid, which will distort the voltage waveform and do serious harm to the power grid and all back-end users. In addition, impact and fluctuating loads, such as electric arc furnace and welding equipment, will not only produce a large number of high-order harmonics but also cause power quality problems such as voltage fluctuation, flicker, and three-phase imbalance, which seriously affect the use efficiency of power. The active power filter of our company includes two commonly used industrial voltage grades of 400V and 600V, three-phase three-wire and three-phase four-wire systems, and the capacity ranges from 30A to 1500A. It has the characteristics of fast response speed, strong filtering capacity, flexible installation, and convenient expansion, and can meet the needs of different users. In addition, the Vesige active power filter has strong expansion ability, and filters with different capacities expand each other so that users can formulate more flexible harmonic treatment schemes.
3p3l/3p4l Power Grid Structure 400V 30kvar Static Var Generator Svg

 APF Characteristics
1.I t can dynamically filter 2-50 harmonics in real - time, and the effective filtering rate can reach 95%
2.T he full response time is less than 10ms
3.B etter control flicker and voltage fluctuation
4.U nique ripple self-elimination  technology, small ripple
5.Multi-function  and multi-mode operation mode
6.H igh stability and reliability
7.D esign life 20 years
8.M odular design for easy installation and maintenance


APF Application fields
1.power consumption system in areas with a large harmonic in the power grid, such as factories, enterprises, etc .
2.manufacturers using high-power nonlinear load and impact load (such as air pump, etc.)
3.power consumption systems with high requirements for power grid quality, such as hospitals, etc .
4.power consumption system requiring comprehensive compensation for reactive power, harmonic and three-phase imbalance

400V series  APF technical parameters
Specifications VAPG04-50DF VAPG04-75DF VAPG04-100DF VAPG04-150DF VAPG04-200DF VAPG04-300DF VAPG04-400DF VAPG04-500DF VAPG04-600DF VAPG04-800DF VAPG04-1000DF VAPG04-1200DF
Rated voltage (VAC)
 
400
Input voltage range (VAC)
 
400 ± 20%
Operating frequency (Hz)
 

50±5%
 
Rated capacity (Kvar)
 
50 75 100 150 200 300 400 500 600 600 800 1200
Overload current multiple
 
1.2
Overall dimension / M (WxDxH)
 
600×800×2200 600×800×2200 600×800×2200 800×800×2200 800×800×2200 1000×800×2200 1400×800×2200 1600×800×2200
Wire system
 
Three-phase three lines / three-phase four lines
Primary incoming line mode Lower incoming line / upper incoming line/cabinet busbar
Operating ambient temperature (ºC)
 
-25  ~ + 4 5 ºC (derating is required above 40 ºC)
Operating ambient humidity (%)
 
< 95% no condensation
Cooling mode
 
Forced air cooling
Degree of protection
 
IP21 / IP 20
Working altitude
 
0 ~ 3000m (> 2000m, need to reduce capacity)
Number of harmonics that can be filtered 2 ~ 50 times
Harmonic compensation rate > 95%
Response time
 
10ms
Display TFT true color touch screen, real-time voltage, and current data display

Intelligent communication
 
TCP/IP GPRS Modbus
Storage, transportation, temperature -40 ~ 70 ° C
Reliability and life
 
Design life 20 years
electromagnetic compatibility Comply with GB 7251-2005 (GB 7261-2000)

Remarks:
1. Single incoming line mode is divided into forwarding line type and backward line type, which can be selected;
2. The product specifications and parameters of the above APF models may change due to different on-site working conditions or      the actual needs of users
3. The matching relationship in the table is not unique, and users can choose by themselves according to the application situation;
4. Due to different options, the size of the APF cabinet may change;
5. Single cabinet installation with size less than 1000mm (included).

600V series APF technical parameters
Specifications VAPG06-50DF VAPG06-100DF VAPG06-200DF VAPG06-300DF VAPG06-400DF VAPG06-500DF VAPG06-600DF VAPG06-800DF VAPG06-1000DF VAPG06-1200DF VAPG06-1600DF VAPG06-2000DF
Rated voltage (VAC)
 
600
Input voltage range (VAC)
 
600 ± 20%
Operating frequency (Hz)
 

50 ± 5%
 
Rated Current (A) 50 100 200 300 400 500 600 800 1000 1200 1600 2000
Overload current multiple
 
1.2
Overall dimension / M (WxDxH)
 
600×800×2200 800×800×2200 800×800×2200 1000×800×2200 1400×800×2200 1600×800×2200 2000×800×2200 2600×800×2200
Wire system
 
Three-phase three lines
Primary incoming line mode Lower incoming line
Operating ambient temperature (ºC)
 
-25  ~ + 4 5 ºC (derating is required above 40 ºC)
Operating ambient humidity (%)
 
< 95% no condensation
Cooling mode
 
Forced air cooling
Degree of protection
 
IP21 / IP 20
Working altitude
 
0 ~ 3000m (> 2000m, need to reduce capacity)
Number of harmonics that can be filtered 2 ~ 50 times
Harmonic compensation rate > 95%
Response time
 
10ms
Display TFT true color touch screen, real-time voltage, and current data display

Intelligent communication
 
TCP/IP GPRS Modbus
Storage, transportation, temperature -40 ~ 70 ° C
Reliability and life
 
Design life 20 years
electromagnetic compatibility Comply with GB 7251-2005 (GB 7261-2000)

Remarks:
1. Single incoming line mode is divided into forwarding line type and backward line type, which can be selected
2. The product specifications and parameters of the above APF models may change due to different on-site working conditions or      the actual needs of users
3. The matching relationship in the table is not unique, and users can choose by themselves according to the application situation
4. Due to different options, the size of the APF cabinet may change;
5. Single cabinet installation with size less than 1200mm (included)

SVG

Compared with the traditional SVC device represented by TCR, the regulation speed of the static var generator (SVG) is faster and the operation range is wider. Moreover, after adopting multiple and equal PWM technical measures, the content of carrier frequency harmonics in compensation current is reduced. More importantly, the reactor and capacitor elements used in SVG are much smaller than those used in SVC, which will greatly reduce the volume of the device. VPV series low voltage static var generator (SVG) has such advantages, which represents the development direction of dynamic var compensation device. The PV series SVG developed and produced by our company realizes the comprehensive coverage of power consumption systems and is widely used in different industries and working conditions. It is divided into 200V series, 400V series, 600V series, and high-voltage series according to the user's service voltage level. The modularization of the power unit makes it easy to expand the capacity of the device, and the independence of the module greatly improves the reliability of the whole machine.
3p3l/3p4l Power Grid Structure 400V 30kvar Static Var Generator Svg


SVG Characteristics
1. Modular design is adopted, and each module unit can compensate reactive power and harmonic separately or at the same time

2. Strong ability to control fluctuation and flicker
3. Using PWM interleaving technology, it's own harmonic is very low
4. Fast response speed, less than or equal to 3MS
5. Low power consumption and small floor area
6. Increase the power grid capacity, reduce losses and purify the power grid
7. Design life 20 years
8. Easy installation and commissioning, no wearing parts , and easy maintenance

 SVG Application field

1.P ower system requiring comprehensive compensation for reactive power and harmonic
2.E lectrolytic industry using special AC voltage
3.P ower consumption systems in areas with low power factor s , such as factories, enterprises, etc .
4.M anufacturers using high-power nonlinear load and impact load (such as air pump, etc.)
5.R emote areas with poor power consumption, such as rural areas, mountainous areas, wind farms, etc .
6.P ower consumption systems with high requirements for power grid quality, such as hospitals, etc .

Technical parameters of 220V series SVG
Specifications VPVG02-140DF VPVG02-280DF VPVG02-420DF VPVG02-560DF VPVG02-840DF VPVG02-1120DF VPVG02-1400DF VPVG02-2100DF VPVG02-2800DF
Rated voltage (VAC)
 
220
Input voltage range (VAC)
 
220±20%
Operating frequency (Hz)
 
50±5%
Rated capacity (Kvar)
 
±140 ±280 ±420 ±560 ±840 ±1120 ±1400 ±2100 ±2800
Equivalent capacitance (Kvar)
 
210 420 630 840 1260 1680 2100 3150 4200
Rated current (A)
 
367 735 1102 1470 2204 2940 3670 5512 7350
Overload current multiple
 
1.2
Overall dimension / M (WxDxH)
 
600×800×2200 900×800×2200 1200×800×2200 1800×800×2200 2900×800×2200 3500×800×2200 5000×800×2200 6500×800×2200
Wire system
 
Three-phase three-wire
Secondary incoming line mode
 
Lower incoming line
Operating ambient temperature (ºC)
 
- 25 ~ + 45 ºC (derating is required above 40 ºC)
Operating ambient humidity (%)
 
< 95% no condensation
Cooling mode
 
Forced air cooling
Degree of protection
 
IP21/IP20
Working altitude
 
0 ~ 3000m (> 2000m, need to reduce capacity)
Reactive power regulation range
 
Continuously adjustable from rated capacitive reactive power to rated inductive reactive power
harmonic
 
Meet the requirements of power quality and harmonics in the public power grid (GB/T 14549-93)
response time
 
3ms
display
 
TFT true color touch screen, real-time voltage, and current data display
Intelligent communication
 
TCP/IP GPRS Modbus
Storage, transportation, temperature -40~70ºCC
Reliability and life
 
Design life 20 years
electromagnetic compatibility Comply with GB 7251-2005 (GB/T 7261-2000)

Remarks:
1. The unit incoming line mode is divided into forwarding line type and backward line type, which can be selected;
2. The product specifications and parameters of the above SVG models may change due to different on-site working conditions or      actual needs of users;
3. The matching relationship in the table is not unique, and users can choose by themselves according to the application situation; 4. Due to different options, the size of the SVG cabinet may change;
5. If the width is less than 1200mm (included), it is a single cabinet installation.


400V series SVG technical parameters
Specifications VPVG04-50DF VPVG04-75DF VPVG04-100DF VPVG04-150DF VPVG04-200DF VPVG04-300DF VPVG04-400DF VPVG04-500DF VPVG04-600DF VPVG04-800DF VPVG04-1000DF VPVG04-1200DF
Rated voltage (VAC)
 
400
Input voltage range (VAC)
 
400±20%
Operating frequency (Hz)
 
50±5%
Rated capacity (Kvar)
 
±50 ±75 ±100 ±150 ±200 ±300 ±400 ±500 ±600 ±800 ±1000 ±1200
Equivalent capacitance (Kvar) 75 115 150 225 300 450 600 750 900 1200 1500 1800
Rated current (A)
 
72 108 144 216 288 432 576 720 864 1152 1440 1728
Overload current multiple
 
1.2
Overall dimension / M (WxDxH)
 
600×800×2200 600×800×2200 800×800×2200 1000×800×2200 1400×800×2200 1600×800×2200
Wire system
 
Three-phase three-wire / three-phase four-wire
Secondary incoming line mode
 
Lower incoming line / upper incoming line/cabinet busbar
Operating ambient temperature (ºC)
 
- 25 ~ + 45 ºC (derating is required above 40 ºC)
Operating ambient humidity (%)
 
< 95% no condensation
Cooling mode
 
Forced air cooling
Degree of protection
 
IP21/IP20
Working altitude
 
0 ~ 3000m (> 2000m, need to reduce capacity)
Reactive power regulation range
 
Continuously adjustable from rated capacitive reactive power to rated inductive reactive power
harmonic
 
Meet the requirements of power quality and harmonics in the public power grid (GB /T 14549-93)
response time
 
3ms
display
 
TFT true color touch screen, real-time voltage, and current data display
Intelligent communication
 
TCP/IP GPRS Modbus
Storage, transportation, temperature -40~70ºCC
Reliability and life
 
Design life 20 years
electromagnetic compatibility Comply with CB 7251-2005 (GB/T 7261-2000)

Remarks:
1. The unit incoming line mode is divided into forwarding line type and backward line type, which can be selected;
2. The product specifications and parameters of the above SVG models may change due to different site conditions or actual              needs;
3. The matching relationship in the table is not unique and can be selected according to the application;
4. Due to different options, the size of the SVG cabinet may change;
5. Single cabinet installation with the width less than 1000mm (included)


 600V series SVG technical parameters
Specifications VPVG06-200DF VPVG06-300DF VPVG06-600DF VPVG06-900DF VPVG06-1200DF VPVG06-1800DF VPVG06-3000DF VPVG06-6000DF VPVG06-9000DF
Rated voltage (VAC)
 
600
Input voltage range (VAC)
 
600±20%
Operating frequency (Hz)
 
50±5%
Rated capacity (Kvar)
 
±200 ±300 ±600 ±900 ±1200 ±1800 ±3000 ±6000 ±9000
Equivalent capacitance (Kvar)
 
300 450 900 1350 1800 2700 4500 9000 13500
Rated current (A)
 
192 289 577 866 1155 1732 2887 5774 8661
Overload current multiple
 
1.2
Overall dimension / M (WxDxH)
 
600×800×2200 600×800×2200 900×800×2200 1200×800×2200 1800×800×2200 3500×800×2200 6500×800×2200 9500×800×2200
Wire system
 
Three-phase three-wire
Secondary incoming line mode
 
Lower incoming line
Operating ambient temperature (ºC)
 
- 25 ~ + 45 ºC (derating is required above 40 ºC)
Operating ambient humidity (%)
 
< 95% no condensation
Cooling mode
 
Forced air cooling
Degree of protection
 
IP21/IP20
Working altitude
 
0 ~ 3000m (> 2000m, need to reduce capacity)
Reactive power regulation range
 
Continuously adjustable from rated capacitive reactive power to rated inductive reactive power
harmonic
 
Meet the requirements of power quality and harmonics in the public power grid (GB/T 14549-93)
response time
 
3ms
display
 
TFT true color touch screen, real-time voltage, and current data display
Intelligent communication
 
TCP/IP GPRS Modbus
Storage, transportation, temperature -40~70ºCC
Reliability and life
 
Design life 20 years
electromagnetic compatibility Comply with GB 7251-2005 (GB 7261-2000)

Technical parameters of 1140V series SVG
Specifications VPVG1-500DF VPVG1-1000DF VPVG1-2000DF VPVG1-3000DF VPVG1-4000DF VPVG1-5000DF VPVG1-6000DF VPVG1-8000DF VPVG1-10000DF
Rated voltage (VAC)
 
1140
Input voltage range (VAC)
 
1140±20%
Operating frequency (Hz)
 
50±5%
Rated capacity (Kvar)
 
±500 ±1000 ±2000 ±3000 ±4000 ±5000 ±6000 ±8000 ±10000
Equivalent capacitance (Kvar)
 
750 1500 3000 4500 6000 7500 9000 12000 10500
Rated current (A)
 
253 506 1013 1520 2026 2532 3039 4052 5065
Overload current multiple
 
1.2
Overall dimension / M (WxDxH)
 
900×900×2200 1200×900×2200 2400×900×2200 3600×900×2200 4800×900×2200 6000×900×2200 7200×900×2200 9600×900×2200 12000×2200
Wire system
 
Three-phase three-wire
Secondary incoming line mode
 
Lower incoming line
Operating ambient temperature (ºC)
 
- 25 ~ + 45 ºC (derating is required above 40 ºC)
Operating ambient humidity (%)
 
< 95% no condensation
Cooling mode
 
Forced air cooling
Degree of protection
 
IP21/IP20
Working altitude
 
0 ~ 3000m (> 2000m, need to reduce capacity)
Reactive power regulation range
 
Continuously adjustable from rated capacitive reactive power to rated inductive reactive power
harmonic
 
Meet the requirements of power quality and harmonics in the public power grid (GB/T 14549-93)
response time
 
3ms
display
 
TFT true color touch screen, real-time voltage, and current data display
Intelligent communication
 
TCP/IP GPRS Modbus
Storage, transportation, temperature -40~70ºCC
Reliability and life
 
Design life 20 years
electromagnetic compatibility Comply with GB 7251-2005 (GB 7261-2000)

Remarks:
1. The unit incoming line mode is divided into forwarding line type and backward line type, which can be selected;
2. The product specifications and parameters of the above SVG models may change due to different on-site working conditions or      actual needs of users;
3. The matching relationship in the table is not unique. Users can choose by themselves according to the application conditions.
4. Due to different options, the size of the SVG cabinet may change;
5. Single-phase installation with a width less than 1200mm (included).


International Standards and specifications
  • Standard voltage level (3 / 3.3 / 4.16 / 6 / 6.6 / 10 / 11KV)
  • Global standards ISO
  • Environmental requirements (RoHS index, limiting the use of certain hazardous substances in electronic and electrical equipment)
  • GB/T 19001-2016 idt ISO9001: 2015
    ISO 45001:2023
    GB/T 24001 -2016 idt ISO14001: 2015
    AAA credit rating
    Test standards:
    EN IEC 61800-3: 2023
    EN 61000-3-12: 2011
    EN 61000-3-11: 2000
3p3l/3p4l Power Grid Structure 400V 30kvar Static Var Generator Svg


Company Profile

3p3l/3p4l Power Grid Structure 400V 30kvar Static Var Generator Svg

Other products we manufacture
3p3l/3p4l Power Grid Structure 400V 30kvar Static Var Generator Svg

 
Application fields

3p3l/3p4l Power Grid Structure 400V 30kvar Static Var Generator Svg 3p3l/3p4l Power Grid Structure 400V 30kvar Static Var Generator Svg
FAQ
Q1: Are you a trading company or manufacturer?
We are a factory.

Q2: How long is your lead time?
It depends on the solution you require but generally 25-60 days. For more specific information, please don't hesitate to ask us

Q3: Do you provide samples? is it free or extra?
Yes, we provide samples and we charge for the samples and the freight cost.
 
Q4. How to ensure product quality? 
Our production strictly follows the ISO9001 quality control system. We give the green (pass) sign only when we finish several quality inspections and high-temperature high-pressure tests


Q5 How about your payment and shipment?
Payment: We accept T/T, LC, Western Union, PayPal, Alipay, etc. terms of payment.


Q7. Do you provide a warranty for the goods? And what are the terms of the warranty?
Yes, we provide 12 months warranty for all the goods. Please, contact us for information regarding warranty, technical support, and any other questions

 

 

PNEUTEC.IT, 2023