| Neocide ® MES Monohydrate (CAS#145224-94-8) | ||||
| Used for IVD products such as preservatives in Flow Sheath Fluid of Flow cytometer, Urine Seaths and buffers for qPCR analysis. Outstanding antimicrobial activity against bacteria and fungi. | ||||
| Part No. | GB02001 | |||
| CAS NO: | 145224-94-8 | |||
| EINECS NO | 224-632-3 | |||
| Ingredients | 2-(N-Morpholino)ethanesulfonic acid, monohydrate | |||
| Content of active ingredients | ≥ 99.5% | |||
| Grade | AR/ACS equivalent | |||
| Molecular Formula | C6H13NO4S.H2O | |||
| Molecular Weight : | 213.25 | |||
| Buffering Range | 5.5~6.7 | |||
| Brand | Neocide® | |||
| Packaging | Pkg of 500g/1Kg/5Kg/12.5Kg/25Kg | |||
| Storage | Room Temperature | |||
| Shelf life | ||||
| Items | Specification | |||
| Appearence | White Crystalline Powder | |||
| APHA (Color, 0.5M aqueous solution) | ≤ 20 | |||
| Solubility (Turbidity,0.5M aqueous solution) | Clear | |||
| Assay (Titration by NaOH) | ≥ 99.5% | |||
| Infrared Spectrum Complies | Conforms to Structure | |||
| pH 1% H2O | 3.5~4.1(25 ºC ) | |||
| UV Absorbance 260mm 0.1M | absorbance ≤ 0.02 | |||
| UV Absorbance 280mm 0.1M | absorbance ≤ 0.02 | |||
| UV Absorbance 260mm 0.5M | absorbance ≤ 0.05 | |||
| UV Absorbance 290mm 0.5M | absorbance ≤ 0.05 | |||
| Loss on drying(105 ºC for 3 Hours) Wt% | ≤ 9.0% | |||
| Sulfated Ash ( 650 ºC for 3 Hours ) Wt% | ≤ 0.1% | |||
| Water insoluble | ≤ 0.03% | |||
| Heavy Metals Pb | ≤ 5ppm | |||
| Iron,Fe | ≤ 5ppm | |||
| Calcium,Ca | ≤ 10ppm | |||
| Usage: | ||||
| The recommended use level for NeoCide* PC-8020 preservative is 0.3-0.5% by weight in Sheath Fluid Liquids, which is synergistic with most of biocides like NeoCide PC-300, BND-10, GML-2 and replace of SodiumAzide. | ||||