Electrical Characteristics
|
|
1. Input Voltage
|
Tri-phase 380V±10%
|
|
2. Output Power
|
10KW
|
|
3. Output Voltage
|
40KV, adjustable output voltage.
|
|
4. Output current
|
250m
A
, adjustable output current.
|
|
5. Output polarity
|
positive or negative as customers' requirements.
|
|
6.Output adjusting mode
|
10-turn potentiometer or 0~10V analog signal control or RS port.
|
|
7. Line regulation
|
≤
0.5%
|
|
8. Load regulation
|
≤
0.5%
|
|
9. Ripple
|
≤
0.5% (optional)
|
|
10. Working mode
|
CC/CV working modes, automatic switchable, withstand long-term continuously working.
|
|
11. Power factor
|
≥
0.9
|
|
12. Total Efficiency
|
≥
85%
|
|
13. Read output
|
Digital LED
|
|
14. Protection
|
-
Input lack voltage protection: cannot be started when input lower than 20% of nominal input voltage
-
Inverter over current protection: automatic shutdown output when inverter current exceeds 120% of rated value.
-
Inverter over temperature protection: automatic shutdown output when inverter heat sink temperature exceeds 70ºC
-
Cooling medium over temperature protection: automatic shutdown output when insulating oil temperature exceeds 70ºC
-
Output over voltage protection: Output limited to rated value when output voltage exceeds set voltage value.
-
Output over current protection: Output voltage decreases when output current exceeds 120% of rated value, even in short-circuit conditions, output current would be limited within 120% of rated value.
-
Output arcing / discharging protection: Within 1us of discharging detected, output shutdown for 1s.
|
|
15. Output display
|
4
1
/
2
digital meter
|
|
16. Cooling
|
Forced air cooling
|
|
17. Operation Temperature
|
-10
ºC
to 40
ºC
|
|
18. Humidity
|
<90%
|
|
19. Dimension
|
560(W)mmX426(H)mmX750(D)mm
|
|
20. Weight
|
A
pprox. 90Kg
|