Mod. | 20 | 25 | 32 | 36 | 42 | 48 | ||
Nominale koelcapaciteit* | KW | 19.5 | 24.8 | 31.2 | 35.6 | 41.3 | 47.4 | |
Nominale verwarmingscapaciteit** | KW | 22.6 | 28.9 | 35.8 | 40.8 | 46.9 | 54.4 | |
Verbinding | ||||||||
Methode | / | Fakkel | Fakkel | Fakkel | Lassen | Lassen | Lassen | |
Diameter van de vloeistofleiding | ¢mm | 9, 52 x 2 | 12, 7x2 | 12, 7x2 | 15, 88 x 1 | 15.88/12.7 | 15.88/12.7 | |
Diameter gasleiding | ¢mm | 15, 88 x 2 | 19.05x2 | 19.05x2 | 28 x 1 | 28/19.05 | 28/19.05 | |
Voeding | / | 230 V/3 N/60 Hz | ||||||
BUITENUNIT | Compressor | |||||||
Hoeveelheid/koelmiddelcircuit | Nr. | 2/2 | 2/2 | 2/2 | 1/1 | 2/2 | 2/2 | |
Ingang koelvermogen* | KW | 7.2 | 9.3 | 11.8 | 12.8 | 15.1 | 17.9 | |
Ingang verwarmingsvermogen** | KW | 7.13 | 9.21 | 11.68 | 12.67 | 14.95 | 17.72 | |
Energieaanpassing | % | 50-100 | 50-100 | 50-100 | 0-100 | 40-60-100 | 33-66-100 | |
Axiale ventilatoren | ||||||||
Hoeveelheid | Nr. | 1 | 1 | 1 | 1 | 2 | 2 | |
Luchtstroom | m3 /u | 9400 | 9400 | 12500 | 14200 | 18800 | 18800 | |
Geluidsdrukniveau *** | DB(A) | 67 | 67 | 68 | 70 | 71 | 71 | |
Nettogewicht | kg | 170 | 180 | 220 | 280 | 260 | 280 | |
BINNENUNIT | Centrifugale ventilatoren | |||||||
Hoeveelheid | Nr. | 2 | 2 | 2 | 2 | 2 | 2 | |
Luchtstroom | m3 /u | 3500 | 4500 | 5650 | 6450 | 7400 | 8550 | |
ESP | PA | 120 | 100 | 150 | 130 | 180 | 200 | |
Geluidsdrukniveau *** | DB(A) | 64 | 64 | 66 | 66 | 68 | 68 | |
Nettogewicht | kg | 90 | 100 | 150 | 160 | 180 | 200 | |
Extra elektrische verwarming **** | KW | 2×3 | 2×4 | 2×5 | 2×6 | 2×6 | 2×8 | |
Extra verwarmingsspoel **** | KW | 22.2 | 28.4 | 35.1 | 40.0 | 46.0 | 53.3 |
Wijz | 52 | 62 | 72 | 88 | 104 | ||
Nominale koelcapaciteit* | KW | 51.3 | 63.3 | 71.3 | 87.9 | 103.7 | |
Nominale verwarmingscapaciteit** | KW | 58.9 | 72.6 | 81.9 | 100.0 | 115.8 | |
Verbinding | |||||||
Methode | / | Lassen | Lassen | Lassen | Lassen | Lassen | |
Diameter van de vloeistofleiding | ¢mm | 15.88/12.7 | 15.88×2 | 15.88×2 | 15.88×2 | 19.05×2 | |
Diameter gasleiding | ¢mm | 28/19.05 | 28×2 | 28×2 | 28×2 | 35×2 | |
Voeding | / | 230 V/3 N/60 Hz | |||||
BUITENUNIT | Compressor | ||||||
Hoeveelheid/koelmiddelcircuit | Nr. | 2/2 | 2/2 | 2/2 | 2/2 | 2/2 | |
Ingang koelvermogen* | KW | 18.4 | 23.1 | 26.6 | 28.1 | 39.3 | |
Ingang verwarmingsvermogen** | KW | 18.22 | 22.87 | 26.33 | 27.82 | 38.91 | |
Energieaanpassing | % | 30-70-100 | 50-100 | 50-100 | 50-100 | 50-100 | |
Axiale ventilatoren | |||||||
Hoeveelheid | Nr. | 2 | 2 | 2 | 2 | 2 | |
Luchtstroom | m3 /u | 21500 | 26500 | 29880 | 36500 | 43500 | |
Geluidsdrukniveau *** | DB(A) | 71 | 71 | 71 | 71 | 71 | |
Nettogewicht | kg | 330 | 460 | 460 | 780 | 800 | |
BINNENUNIT | Centrifugale ventilatoren | ||||||
Hoeveelheid | Nr. | 2 | 2 | 2 | 2 | 2 | |
Luchtstroom | m3 /u | 9250 | 11450 | 12900 | 14800 | 17100 | |
ESP | PA | 200 | 300 | 300 | 280 | 500 | |
Geluidsdrukniveau *** | DB(A) | 68 | 68 | 69 | 69 | 70 | |
Nettogewicht | kg | 220 | 230 | 300 | 320 | 400 | |
Extra elektrische verwarming **** | KW | 2×8 | 2×10 | 2×10 | 2×12 | 2×14 | |
Extra verwarmingsspoel **** | KW | 57.8 | 71.2 | 80.3 | 98.0 | 113.5 |