| MODEL | RSP-500-3.3 | RSP-500-4 | RSP-500-5 | RSP-500-12 | |
| OUTPUT | DC VOLTAGE | 3.3V | 4V | 5V | 12V |
| CURRENT RANGE | 90A | 90A | 90A | 41.7A | |
| RATED CURRENT | 0 ~ 90A | 0 ~ 90A | 0 ~ 90A | 0 ~ 41.7A | |
| RATED POWER | 297W | 360W | 450W | 500.4W | |
| RIPPLE & NOISE | 120mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | |
| VOLTAGE ADJ. RANGE | 2.8 ~ 3.6V | 3.6 ~ 4.3V | 4.5 ~ 5.5V | 10 ~ 13.2V | |
| VOLTAGE TOLERANCE | ±2.0% | ±2.0% | ±2.0% | ±1.0% | |
| LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.3% | |
| LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±0.5% | |
| SETUP, RISE TIME | 1500ms, 80ms/230VAC 3000ms, 80ms/115VAC at full load | ||||
| HOLD UP TIME | 18ms/230VAC 14ms/115VAC at full load | ||||
| INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | |||
| FREQUENCY RANGE | 47 ~ 63Hz | ||||
| POWER FACTOR | PF>0.95/230VAC PF>0.98/115VAC at full load | ||||
| EFFICIENCY | 81% | 83% | 84% | 88% | |
| AC CURRENT | 5.3A/115VAC 2.65 A/230VAC | ||||
| INRUSH CURRENT | 20A/115VAC 40A/230VAC | ||||
| LEAKAGE CURRENT | <2mA / 240VAC | ||||
| PROTECTION | OVER LOAD | 105 ~ 130% rated output power | |||
| Protection type : Constant current limiting, recovers automatically after fault condition is removed | |||||
| OVER VOLTAGE | 3.8 ~ 4.5V | 4.5 ~ 5.3V | 5.75 ~ 6.75V | 13.8 ~ 16.2V | |
| Protection type : Shut down o/p voltage, re-power on to recover | |||||
| OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | ||||
| FUNCTION | REMOTE CONTROL |
POWER ON:open or 0~0.8VDC between RC+(Pin 4)&RC-(Pin3) on CN100
POWER OFF: 4~10VDC between RC+(Pin 4)&RC-(Pin3) on CN100 |
|||
| REMOTE SENSE | Compensate voltage drop on the load wiring up to 0.3V | ||||
| FAN CONTROL |
RTH2≥50°C±10°C Fan on ; RTH2≤40°C±10°C Fan off
(Fan always on for 3.3~5V,Fan ON/OFF control for 12~48V) |
||||
| ENVIRONMENT | WORKING TEMP. | -30 ~ +70°C (Refer to "Derating Curve") | |||
| WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
| STORAGE TEMP., HUMIDITY | -40 ~ +85°C, 10 ~ 95% RH | ||||
| TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C ) | ||||
| VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||
| SAFETY &EMC | SAFETY STANDARDS | U60950-1, TUV EN60950-1 approved | |||
| WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||
| ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | ||||
| EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 | ||||
| EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3 heavy industry level, criteria A | ||||
| OTHERS | MTBF | 187.7K hrs min. MIL-HDBK-217F (25°C) | |||
| DIMENSION | 230*127*40.5mm (L*W*H) | ||||
| PACKING | 1.3Kg; 9pcs/12.7Kg/0.7CUFT | ||||
| MODEL | RSP-500-15 | RSP-500-24 | RSP-500-27 | RSP-500-48 | |
| OUTPUT | DC VOLTAGE | 15V | 24V | 27V | 48V |
| CURRENT RANGE | 33.4A | 21A | 18.6A | 10.5A | |
| RATED CURRENT | 0 ~ 33.4A | 0 ~ 21A | 0 ~ 18.6A | 0 ~ 10.5A | |
| RATED POWER | 501W | 504W | 502.2W | 504W | |
| RIPPLE & NOISE | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
| VOLTAGE ADJ. RANGE | 13.5 ~ 18V | 20 ~ 26.4V | 26 ~ 30V | 41 ~ 56V | |
| VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
| LINE REGULATION | ±0.3% | ±0.2% | ±0.2% | ±0.2% | |
| LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
| SETUP, RISE TIME | 1500ms, 80ms/230VAC 3000ms, 80ms/115VAC at full load | ||||
| HOLD UP TIME | 18ms/230VAC 14ms/115VAC at full load | ||||
| INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | |||
| FREQUENCY RANGE | 47 ~ 63Hz | ||||
| POWER FACTOR | PF>0.95/230VAC PF>0.98/115VAC at full load | ||||
| EFFICIENCY | 88% | 89% | 89.5% | 90.5% | |
| AC CURRENT | 5.3A/115VAC 2.65 A/230VAC | ||||
| INRUSH CURRENT | 20A/115VAC 40A/230VAC | ||||
| LEAKAGE CURRENT | <2mA / 240VAC | ||||
| PROTECTION | OVER LOAD | 105 ~ 130% rated output power | |||
| Protection type : Constant current limiting, recovers automatically after fault condition is removed | |||||
| OVER VOLTAGE | 18.8 ~ 21.8V | 27.6 ~ 32.4V | 32.9 ~ 38.3V | 58.4 ~ 68V | |
| Protection type : Shut down o/p voltage, re-power on to recover | |||||
| OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | ||||
| FUNCTION | REMOTE CONTROL |
POWER ON:open or 0~0.8VDC between RC+(Pin 4)&RC-(Pin3) on CN100
POWER OFF: 4~10VDC between RC+(Pin 4)&RC-(Pin3) on CN100 |
|||
| REMOTE SENSE | Compensate voltage drop on the load wiring up to 0.3V | ||||
| FAN CONTROL |
RTH2≥50°C±10°C Fan on ; RTH2≤40°C±10°C Fan off
(Fan always on for 3.3~5V,Fan ON/OFF control for 12~48V) |
||||
| ENVIRONMENT | WORKING TEMP. | -30 ~ +70°C (Refer to "Derating Curve") | |||
| WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
| STORAGE TEMP., HUMIDITY | -40 ~ +85°C, 10 ~ 95% RH | ||||
| TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C ) | ||||
| VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||
| SAFETY &EMC | SAFETY STANDARDS | U60950-1, TUV EN60950-1 approved | |||
| WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||
| ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | ||||
| EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 | ||||
| EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3 heavy industry level, criteria A | ||||
| OTHERS | MTBF | 187.7K hrs min. MIL-HDBK-217F (25°C) | |||
| DIMENSION | 230*127*40.5mm (L*W*H) | ||||
| PACKING | 1.3Kg; 9pcs/12.7Kg/0.7CUFT | ||||