Model | | s-75-5 | s-75-12 | s-75-15 | s-75-24 |
| Dc output Voltage | 5v | 12v | 15V | 24V |
voltage tolerance | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Rated current | 15A | 6A | 5A | 3A |
Related Power | 75w | 75w | 75w | 75w |
wave&Noise | 75mVp-p | 10omVp:p | 10omVp-p | 100mVp-p |
Adjustable range for Dc votage | ±10% | ±10% | ±10% | ±10% |
set up,rise,hold up time | 200ms 10oms 3oms |
Input | Voltage Range | 85~132VAC 170-264VAC 47-63HZ240-370VDc |
Input Current | 1.2A/115VAC0.6A/230VAC |
Efficiency | 71% 78% | 78% | 82% |
Acinrush current | cold start current 15A/115V 30A/230VAC |
Leakage current | <0.5mA/240VAC |
Protection | overload | Related output power 105-150% start overload protectlon |
Protection type: cutoff output, recovery after restart power |
over voltage | 5.75V-6.75V | 13.8v-16.2v | 17.2v-20.2v | 27.6V-32.4v |
Hiccup mode,recovers automatically after fault condition |
Environment | working remp humidity | -10+60"C 20%~90%RH |
stor temp, humidity | -20~+85"C 20%~90%RH Non-condensing |
safety | withstand voltage | l/P-O/P:1.5KVAc 1min |
l/P-FG:1.5KVAC 1min |
0/P-FG:0.5KVAC 1min |
Standard | Safety standard | Fit UL1012 |
Refer | Design refer to GB4943UL60950,EN60950 |
EMC standard | Design refer to GB9254,EN55022 Class A |
size | size | 159*98*38mm |
Package | 0.5kg.40pcs/20kg |