Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE

Model NO.
GFL1-100B-2
Arc-extinguishing Medium
Air
Installation
DIN Rail Mount
Structure
MCB
Poles Number
1
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, Intertek Semko, Ukca
Short-Circuit Current
10,000A
Break Time
<0.1s
Rated Residual Breaking Capacity
500(in=2540A) 630(in=63A)
Rated Residual Operation Current
30mA
Electrical Life
2,000 Cycles
Mechanical Life
4,000 Cycles
Dielectric Test Voltage
2.5kv
Rated Impulse Withstands Voltage
4000V
Rated Voltage
2p 240V~, 4p 415V~
Poles
2p,4p
Rated Frequency
50/60Hz
Insulation Voltage
500V
Type (Wave Form of The Earth Leakage)
B
Rated Current
25,40,63,80,100A
Mode
Electromagnetic
Transport Package
Customized Package and Express,Sea or Air Shipment
Specification
4P
Trademark
Good Future
Origin
China
HS Code
8536200000
Production Capacity
3700000PCS /Year
Package Size
10.00cm * 10.00cm * 10.00cm
Package Gross Weight
0.500kg
Reference Price
$ 5.40 - 10.80

Product Description

Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE
Features Mode Electromagnetic
Type (wave form of the earth leakage sensed) B
Rated current In 25,40,63,80,100A
Poles 2P,4P
Rated voltage Ue 2P 240V~, 4P 415V~
Insulation voltage Ui 500V
Rated frequency 50/60Hz
Rated residual operation current(I△n) 30mA
Rated residual making and breaking capacity (I△m) 500(In=2540A) 630(In=63A)
Short-circuit current Inc= I△c 10,000A
SCPD fuse
 
 
Break time under I△n ≤0.1s
Rated impulse withstands voltage (1.5/50) Uimp 4000V
Dielectric test voltage at ind.Freq. for 1min 2.5kV
Electrical life 2,000 Cycles
Mechanical life 4,000 Cycles
Installation Contact position indicator Yes
Protection degree IP20
Ambient temperature (with daily average≤35ºC) -5ºC~+40ºC
Storage temperature -25ºC~+70ºC
Terminal connection type Cable/Pin-type busbar/U-type busbar
Terminal size top/bottom for cable 35mm2 18-3AWG
Terminal size top/bottom for busbar 35mm 2  18-3AWG
Tightening torque 2.5Nm 22In-lbs
Mounting On DIN rail EN60715(35mm) by means of fast clip device
Connection Power supply in both directions
Tripping Current Range Lagging Angle I△n>0.01A I△n≤0.01A
0.35I△n≤I△≤1.4I△n 0.35I△n≤I△≤2I△n
90° 0.25I△n≤I△≤1.4I△n 0.25I△n≤I△≤2I△n
135° 0.11I△n≤I△≤1.4I△n 0.11I△n≤I△≤2I△n
Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE Good Future 4p 10ka Residual Current Operated Circuit Breaker RCCB Ukca CE

 