Item | Value |
Operating speed | 0.1mm-1m/s (no lever) |
Operating frequency | Mechanical 60 cycles/min; electrical 25 cycles/min |
Insulation resistance | ≥100MΩ(500VDC) |
Contact resistance | ≤50mΩ |
(Test voltage) Between not continuous terminals of the same polarity | AC1000V , 50/60Hz , 1min |
(Test voltage) Between current-carrying metal parts and ground(case),
and between each terminal and non-current -carrying metal parts. |
AC2000V , 50/60Hz , 1min |
Vibration resistance | 10-55Hz , 1.5mm Double amplitude |
Shock resistance |
endurance : 1000m/s
2
max
Wrong action : 300m/s 2 max |
Electric shock proof protection grade | II class |
Degree protection provided by enclosure | IEC IP60(specific specification) |
Life |
Mechanical≥500,000 cycles
Electrical ≥ 50,000 cycles |
Safety approvals | UL ,CUL,ENEC, DEMKO , EK , CQC |