GTW1 Air Circuit Breaker
1-OEM Service Offered
2-Payment : LC/TT
3-Delivery : By sea / By train
4-FOB/CIF/CIP
Specification
Rated operational voltage of the breaker is AC400/415/690V, with the rated current ranges from 630A to 6300A
Compact design with fixed and withdrawerable type
Standard of ACB: IEC/EC 60947-2
Telecommunication protocal: The protocals of Modbus, Profibus-DP and Device Net are avaiable
Breaking capacity under 415V
|
Model
|
|
|
GTW1-1000
|
GTW1-2000
|
GTW1-3200
|
GTW1-4000
|
GTW1-6300
|
|
IEC60947-2 GB/T14048.2
|
|
Shell frame level current
|
Inm(A)
|
|
1000
|
2000
|
3200
|
4000
|
6300
|
|
Electrical Performance
|
|
|
|
|
|
|
|
|
|
Number of poles
|
|
|
3P
|
4P
|
3P
|
4P
|
3P
|
4P
|
3P
|
4P
|
3P
|
4P
|
|
Operating frequency
|
(Hz)
|
|
50
|
50
|
50
|
50
|
50
|
|
Rated working voltage
|
Ue(V)
|
|
400/690
|
400/690
|
400/690
|
400/690
|
400/690
|
|
Rated current +40ºC
|
In(A)
|
|
200,400,630,800,1000
|
630,800,1000,1250,1600,2000
|
2000,2500,3200
|
3200,3600,4000
|
4000,5000,6300
|
|
Rated insulation voltage
|
Ui(V)
|
|
800
|
1000
|
1000
|
1000
|
1000
|
|
Rated impulse withstand voltage
|
Uimp(kV)
|
|
8
|
12
|
12
|
12
|
12
|
|
Pole N rated current
|
In(A)
|
|
100%
|
100%
|
100%
|
100%
|
100%
|
|
Breaking type
|
|
|
-
|
M
|
H
|
|
-
|
-
|
|
Rated ultimate short-circuit segmentation capability
|
Icu(kA)
|
400V
|
50
|
85
|
100
|
100
|
120
|
|
690V
|
30
|
50
|
65
|
65
|
80
|
|
Rated running short-circuit segmentation capability
|
Ics(kA)
|
400V
|
35
|
50
|
65
|
65
|
65
|
80
|
|
690V
|
25
|
40
|
50
|
50
|
70
|
|
Rated short-time withstand current(effective value)
|
Icw(kA)
|
400V
|
35(1s)
|
50(1S)
|
65(1S)
|
65(1S)
|
65(1S)
|
85(1S)
|
|
690V
|
25(1S)
|
40(1S)
|
50(1S)
|
50(1S)
|
65(1S)
|
|
Operating time
|
(ms)
|
Disjunction
|
23~32
|
23~32
|
23-32
|
23-32
|
23-32
|
|
Switch off
|
<70
|
<70
|
<70
|
<70
|
<70
|
|
Flashover distance
|
(mm)
|
|
0
|
0
|
0
|
0
|
0
|
|
Service life
|
for mechanical
|
Free of maintenance
|
15000
|
10000
|
5000
|
5000
|
3000
|
|
service life(times)
|
Maintained
|
30000
|
20000
|
10000
|
10000
|
6000
|
|
Electrical life (times)
|
400V
|
6000
|
6500
|
3000
|
1500
|
500
|
|
900V
|
3000
|
3000
|
1500
|
750
|
300
|
|
Separating function (drawer type)
|
O
|
O
|
O
|
O
|
O
|
|
Protection:
|
|
Intelligent controller
|
O
|
O
|
O
|
O
|
O
|
|
Pole N protection capability (only 4P and 3P+N)
|
O
|
O
|
O
|
O
|
O
|
|
Connection And Installation:
|
|
Utilization category
|
B
|
B
|
B
|
B
|
B
|
|
Installation category
|
Circuit breaker(including the primary lateral line circle)
|
IV
|
IV
|
IV
|
IV
|
IV
|
|
Auxiliary circuit (except for primary coil RB)
|
III
|
III
|
III
|
III
|
III
|
|
Pollution degree
|
3
|
3
|
3
|
3
|
3
|
|
Connection mode Horizontal
|
Vertical/Horizontal
|
Vertical/Horizontal
|
Vertical/Horizontal
|
Vertical/Horizontal
|
Vertical/Horizontal
|
|
Incoming line method
|
Up/Down
|
Up/Down
|
Up/Down
|
Up/Down
|
Up/Down
|
|
Installation Method
|
Fixed Type (3/4)
|
Drawer Type(3/4)
|
Fixed Type (3/4)
|
Drawer Type(3/4)
|
Fixed Type (3/4)
|
Drawer Type(3/4)
|
Fixed Type (3)
|
Drawer Type(3/4)
|
Fixed Type (3/4)
|
Drawer Type(3)
|
|
Outline Dimension
|
Width(W)
|
274/344
|
284/354
|
362/457
|
407/500
|
422/537
|
435/550
|
537
|
550/790
|
813/928
|
928
|
|
Depth(D)
|
289
|
373
|
373
|
461
|
363
|
494
|
424
|
494/504
|
504
|
504
|
|
Height(H)
|
315
|
362
|
402
|
432
|
402
|
432
|
402
|
432/452
|
433
|
433
|
|
O
Standard Configuration
|
O Optional
|
-None
|
|
|
|
|
|
|
|
|
|