| Technical Data | Austa-1P1K1G | Austa-1P2K1G | Austa-1P3K1G |
| Description | 1kw 2kva solar on Grid pure sine wave Power Inverter | ||
| Energy source | Grid-connected PV | ||
| Input Side | |||
| Max.DC Input Power(kW) | 1.3 | 2.6 | 3.9 |
| Max.DC Input Voltage(V) | 500 | 500 | 500 |
| Start-up DC Input Voltage(V) | 80 | 120 | 120 |
| MPPT Operating Range(V) | 70-500 | 100-500 | 100-500 |
| Max.DC Input Current(A) | 13 | 13 | 13 |
| Number of MPPT/String per MPPT | 1/1 | 1/1 | 1/1 |
| OutPut Side | |||
| Rated Output Power(kW) | 1 | 2 | 3 |
| Max.Active Power(kW) | 1.1 | 2.2 | 3.3 |
| Rated AC Grid Voltage(V) | 230 | 230 | 230 |
| AC Grid Voltage Range(V) | 160-300 | 160-300 | 160-300 |
| Rated Grid Frequency(Hz) | 50/60(Optional) | 50/60(Optional) | 50/60(Optional) |
| Operating Phase | Single phase | Single phase | Single phase |
| Rated AC Grid Output Current(A) | 4.3 | 8.7 | 13.1 |
| Max.AC Output Current(A) | 4.7 | 9.6 | 14 |
| Output Power Factor | 0.8 leading to 0.8 lagging | ||
| Grid Current THD | <3% | <3% | <3% |
| DC Injection Current(mA) | <0.5% | <0.5% | <0.5% |
| Grid Frequency Range | 47-52 or 57-62(Optional) | 47-52 or 57-62(Optional) | 47-52 or 57-62(Optional) |
| Efficiency | |||
| Max.Efficiency | 0.973 | 0.973 | 0.975 |
| Euro Efficiency | 0.971 | 0.971 | 0.973 |
| MPPT Efficiency | >99% | >99% | >99% |
| Protection | |||
| Anti-islanding Protection | Integrated | ||
| DC Reverse-Polarity Protection | Integrated | ||
| DC Surge Protection | Integrated(Type II) | ||
| AC Surge Protection | Integrated(Type II) | ||
| AC Short Circuit Protection | Integrated | ||
| AC Output Overcurrent Protection | Integrated | ||
| Output Overvoltage Protection | Integrated | ||
| AC Grid Monitoring | Integrated | ||
| Ground Fault Monitoring | Integrated | ||
| Insulation Resistance Protection | Integrated | ||
| Residual Current Monitoring Unit | Integrated | ||
| Temperature Protection | Integrated | ||
| Integrated DC Switch | Optional | ||
| General Data | |||
| Size(mm) | 330W*310H*115D | ||
| Weight(kg) | 6kg | ||
| Topology | Transforemerless | ||
| Internal Consumption | <1W(Night) | ||
| Running Temperature | -25-60ºC | ||
| Ingress Protection | IP65 | ||
| Noise Emission(Typical) | <30dB | ||
| Cooling Concept | Intelligent cooling | ||
| Max.Operating Altitude Without Derating | 2000m | ||
| Designed lifetime | >20years | ||
| Operating Surroundings Humidity | 0-100% | ||
| Features | |||
| DC Connection | MC-4 mateable | ||
| AC Connection | IP65 rated plug | ||
| Display | LCD1602 | ||
| Interface | RS485/RS232 | ||
| Certifications&Standards | |||
| Grid Regulation | IEC61727 /62116 /60068 /61683 | IEC61727 /62116 /60068 /61683 | IEC61727 /62116 /60068 /61683 /INMETRO (ABNTNBR 16149 /16150) |
| Safety Regulation | IEC/EN62109-1/2 | ||
| EMC Regulation | / | ||