Technical parameters
|
SUN2000-3KTL-L1
|
|
|
|
||||||
|
Efficiency
|
|
|||||||||
|
Maximum efficiency
|
98.3%
|
98.4%
|
98.4%
|
98.4%
|
||||||
|
The input
|
|
|||||||||
|
Max recommended module power
|
4500Wp
|
6000Wp
|
7500Wp
|
9000Wp
|
||||||
|
Maximum DC input voltage
|
600V
|
|
||||||||
|
Start voltage
|
100v
|
|
||||||||
|
MPPT Voltage range
|
90V~560V
|
|
||||||||
|
Maximum input current per MPPT channel
|
12.5A
|
|
||||||||
|
Rated input voltage
|
360V
|
|
||||||||
|
Maximum input number
|
2
|
|
||||||||
|
Number of MPPT
|
2
|
|
||||||||
|
The output
|
|
|||||||||
|
Rated output
|
3000W
|
4000W
|
5000W
|
6000W
|
||||||
|
Maximum apparent power
|
3300VA
|
4400VA
|
5500VA
|
6000VA
|
||||||
|
Maximum active power
|
3300W
|
4400W
|
5000W
|
5000W
|
||||||
|
Rated output voltage
|
220Vac/230Vac/240Vac
|
|
||||||||
|
Output voltage frequency
|
50HZ
|
|
||||||||
|
Maximum output current
|
15A
|
20A
|
25A
|
27.3A
|
||||||
|
Maximum total harmonic distortion
|
<3%
|
|
||||||||
|
Protection
|
|
|
||||||||
|
Input DC switch
|
support
|
|
||||||||
|
Afci DC arc protection
|
support
|
|
||||||||
|
Anti-islanding protection
|
support
|
|
||||||||
|
Output overcurrent protection
|
support
|
|
||||||||
|
Output reverse connection protection
|
support
|
|
||||||||
|
String fault detection
|
support
|
|
||||||||
|
DC surge protection
|
support
|
|
||||||||
|
AC surge protection
|
support
|
|
||||||||
|
Insulation resistance detection
|
support
|
|
||||||||
|
Residual current monitoring
|
support
|
|
||||||||
|
Grid monitoring
|
support
|
|||||||||