| Components Item | Function and usage |
| CIP spray ball | Wash &clean tank inside surface and devices automatic ,which should connect to the CIP machine station |
| Vent filter | Filter air to prevent the bacteria into the tank ,also can release the tank inside pressure. |
| Temperature sensor (gauge) | Indicate inside tank temperature and PID temperature control with the necessary valve and fittings |
| Pressure sensor (gauge) | Indicate the inside tank pressure |
| PH sensor | Indicate the product PH data |
| PO2 sensor | Indicate the product Oxygen content |
| Level sensor (gauge) | Indicate the inside tank product level height ,there are have different models :(static) pressure type ,ultrasonic type ,radar type ,glass tube type ,plate sight glass type . |
| Load cell | Indicate the product weight |
| VFD ( inverter ) | Control and adjust agitator speed |
| Safety valve | Release inside tank pressure to protect the tank safety |
| Flow meter | Indicate the solution inlet and outlet volume |
| Sight light | Indicate inside tank bright for watching easily |
| Manhole (handhole ) | Charge solid product into tank ,also can be used for maintenance inside tank components. |
| Sampling valve | Take inside tank products sample for offline checking |
|
Model
Item |
PT-50 | PT-200 | PT-1000 | PT-2000 | PT-5000 | ||||
| Tank work volume:L | 50 | 200 | 1000 | 2000 | 5000 | ||||
| Motor power for high shear emulsifying:Kw | 1.1 | 1.5 | 4.0 | 5.5 | 15 | ||||
| Agitator speed for high shear emulsifying :RPM | 0-1440 or 0-2900 | ||||||||
| Motor power propeller type agitator g:Kw | 0.37 | 0.75 | 2.5 | 3.0 | 5.5 | ||||
| Agitator speed for propeller type agitator :RPM | 0-150 | ||||||||
| Motor power anchor type agitator g:Kw | 0.55 | 1.5 | 4.0 | 5.5 | 11 | ||||
| Agitator speed for anchor type agitator :RPM | 0-45 | ||||||||
| Inside shell pressure MPa | -0.1/0.3 (can be done as client's URS) | ||||||||
| Jacket pressure MPa | 0.3 (can be done as client's URS) | ||||||||
| Jacket heating medium | Steam/hot water | ||||||||
| Jacket type | Single full/limpet coil/dimple jacket /inside coil tube | ||||||||